Estimation of underground hydrogen storage capacity in depleted gas reservoirs using CO2 as cushion gas

被引:7
|
作者
He, Youwei [1 ]
Xie, Yixiang [1 ]
Qiao, Yu [1 ]
Qin, Jiazheng [1 ]
Tang, Yong [1 ]
机构
[1] Southwest Petr Univ, State Key Lab Oil & Gas Reservoir Geol & Exploitat, Chengdu 610500, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Underground hydrogen storage; Energy storage efficiency; Hydrogen storage capacity; CO; 2; sequestration; Cushion gas; Depleted gas reservoirs; NATURAL HYDROGEN; POROUS-MEDIA; H-2; STORAGE; BOURAKEBOUGOU; POLICY;
D O I
10.1016/j.apenergy.2024.124093
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Underground hydrogen storage (UHS) is an effective means to solve large-scale hydrogen energy storage. The depleted gas reservoirs can be used as the potential UHS targets due to its huge storage space, good sealing ability, and the existing facilities. CO2 can be injected as the cushion gas to reduce the hydrogen loss, improve energy storage efficiency and achieve carbon sequestration. This work proposes a novel method to estimate the hydrogen storage capacity in depleted gas reservoirs using CO2 as cushion gas. The multi-components (H2-CO2CH4-H2O) material balance equations are further developed by integrating the edge/bottom water and water invasion, gas (e.g., CO2, H2, CH4) dissolution in formation water as well as caprock breakthrough and fault instability. The maximum UHS operating pressure can be determined by calculating the caprock-breakthrough pressure and the fault-instability pressure. A numerical model is established to validate the proposed UHS capacity model in this work. The impact of dominated factors on the UHS capacity is discussed. The proposed method has been applied to evaluate the UHS capacity of a depleted gas reservoir in the Sichuan Basin of China. Results show that the model validation verifies the accuracy of the proposed model since the average error is only 1.76% between the analytical model developed in this work and the numerical model. The maximum pressure threshold presents the most significant impact on the UHS capacity, followed by CO2 cushion gas volume, formation temperature and water body size. The maximum pressure threshold of formation is determined to be 42 MPa. The hydrogen storage capacity under different CO2 cushion gas injection conditions is calculated. The UHS capacity is increased by 7.76% and 8.61% with dissolution when VCO2_inj is 3000 x 104 m3 and 4000 x 104 m3. The UHS capacity of Well #P4 is 6076 x 104 m3 when VCO2_inj is 4000 x 104 m3 based on the proposed model in this work. This work provides an effective approach to evaluate the hydrogen storage capacity and improve hydrogen storage efficiency by using CO2 as cushion gas considering caprock breakthrough, fault slip and gas dissolution. The established model provides important references for calculating the storage capacity of gas storage facilities in oil and gas reservoirs with edge and bottom water as well as for gas storage in aquifers.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Hydrogen storage in depleted gas reservoirs with carbon dioxide as a cushion gas: Exploring a lateral gas separation strategy to reduce gas mixing
    Williams, Harri A.
    Heinemann, Niklas
    Molnar, Ian L.
    Veloso, Fernanda de Mesquita L.
    Gladding, Toni
    Rashwan, Tarek L.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2025, 102 : 1116 - 1129
  • [32] Suitability of depleted gas reservoirs for geological CO2 storage: A simulation study
    Raza, Arshad
    Gholami, Raoof
    Rezaee, Reza
    Rasouli, Vamegh
    Bhatti, Amanat Ali
    Bing, Chua Han
    GREENHOUSE GASES-SCIENCE AND TECHNOLOGY, 2018, 8 (05): : 876 - 897
  • [33] Effect of rock surface wettability on hydrogen-cushion gas adsorption with application to hydrogen storage in depleted oil and gas reservoirs
    Mirchi, Vahideh
    Dejam, Morteza
    JOURNAL OF ENERGY STORAGE, 2023, 73
  • [34] CO2-hydrate formation in depleted gas reservoirs - A methodology for CO2 storage
    Zatsepina, Olga Ye
    Pooladi-Darvish, Mehran
    10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 3949 - 3956
  • [35] CO2 storage capacity estimation by considering CO2 Dissolution: A case study in a depleted gas Reservoir, China
    He, Youwei
    Liu, Mengyun
    Tang, Yong
    Jia, Cunqi
    Wang, Yong
    Rui, Zhenhua
    JOURNAL OF HYDROLOGY, 2024, 630
  • [36] Underground hydrogen storage in depleted gas reservoirs with hydraulic fractures: Numerical modeling and simulation
    Wang, Haiyang
    Jie, Yenan
    Zhou, Desheng
    Ma, Xianlin
    JOURNAL OF ENERGY STORAGE, 2024, 97
  • [37] Effect of flue-gas impurities on the process of injection and storage of CO2 in depleted gas reservoirs
    Nogueira, Marjorie
    Mamora, Daulat D.
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2008, 130 (01):
  • [38] Numerical modeling for CO2 storage with impurities associated with enhanced gas recovery in depleted gas reservoirs
    Cao, Cheng
    Hou, Zhengmeng
    Li, Zaoyuan
    Pu, Xiaolin
    Liao, Jianxing
    Wang, Gui
    JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2022, 102
  • [39] Risk Assessment for Underground Natural Gas Storage in Depleted Oil and Gas Reservoirs
    Xie Li-hua
    Li He-lin
    Zhang Hong
    PROCEEDINGS OF 2009 INTERNATIONAL SYMPOSIUM ON RISK CONTROL AND MANAGEMENT OF DESIGN, CONSTRUCTION AND OPERATION IN UNDERGROUND ENGINEERING, 2009, : 379 - 382
  • [40] Estimating the hydrogen adsorption in depleted shale gas reservoirs for kerogens in underground hydrogen storage using machine learning algorithms
    Mwakipunda, Grant Charles
    Nafouanti, Mouigni Baraka
    Ibrahim, AL-Wesabi
    Yu, Long
    FUEL, 2025, 388