Highly Accurate and Precise Automated Cup-to-Disc Ratio Quanti fi cation for Glaucoma Screening

被引:0
|
作者
Chaurasia, Abadh K. [1 ]
Greatbatch, Connor J. [1 ]
Han, Xikun [2 ,3 ]
Gharahkhani, Puya [2 ,3 ,4 ]
Mackey, David A. [5 ]
MacGregor, Stuart [2 ,3 ]
Craig, Jamie E. [6 ]
Hewitt, Alex W. [1 ,7 ]
机构
[1] Univ Tasmania, Menzies Inst Med Res, 17 Liverpool St, Hobart, Tas 7000, Australia
[2] QIMR Berghofer Med Res Inst, Brisbane, Qld, Australia
[3] Univ Queensland, Sch Med, Brisbane, Qld, Australia
[4] Queensland Univ Technol, Sch Biomed Sci, Fac Hlth, Brisbane, Qld, Australia
[5] Univ Western Australia, Lions Eye Inst, Ctr Vis Sci, Nedlands, WA, Australia
[6] Flinders Univ S Australia, Dept Ophthalmol, Flinders Med Ctr, Bedford Pk, SA, Australia
[7] Univ Melbourne, Ctr Eye Res Australia, Melbourne, Vic, Australia
来源
OPHTHALMOLOGY SCIENCE | 2024年 / 4卷 / 05期
基金
英国医学研究理事会;
关键词
Computer Vision; Deep Learning; Glaucoma; Fundus Image; UK Biobank; OPTIC DISC; SEGMENTATION; DISCOVERY; NETWORK; SIZE;
D O I
10.1016/j.xops.2024.100540
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: An enlarged cup-to-disc ratio (CDR) is a hallmark of glaucomatous optic neuropathy. Manual assessment of the CDR may be less accurate and more time-consuming than automated methods. Here, we sought to develop and validate a deep learning- based algorithm to automatically determine the CDR from fundus images. Design: Algorithm development for estimating CDR using fundus data from a population-based observational study. Participants: A total of 181 768 fundus images from the United Kingdom Biobank (UKBB), Drishti_GS, and EyePACS. Methods: FastAI and PyTorch libraries were used to train a convolutional neural network- based model on fundus images from the UKBB. Models were constructed to determine image gradability (classification analysis) as well as to estimate CDR (regression analysis). The best-performing model was then validated for use in glaucoma screening using a multiethnic dataset from EyePACS and Drishti_GS. Main Outcome Measures: The area under the receiver operating characteristic curve and coefficient of determination. Results: Our gradability model vgg19_batch normalization (bn) achieved an accuracy of 97.13% on a validation set of 16 045 images, with 99.26% precision and area under the receiver operating characteristic curve of 96.56%. Using regression analysis, our best-performing model (trained on the vgg19_bn architecture) attained a coefficient of determination of 0.8514 (95% confidence interval [CI]: 0.8459- 0.8568), while the mean squared error was 0.0050 (95% CI: 0.0048- 0.0051) and mean absolute error was 0.0551 (95% CI: 0.0543- 0.0559) on a validation set of 12 183 images for determining CDR. The regression point was converted into classification metrics using a tolerance of 0.2 for 20 classes; the classification metrics achieved an accuracy of 99.20%. The EyePACS dataset (98 172 healthy, 3270 glaucoma) was then used to externally validate the model for glaucoma classification, with an accuracy, sensitivity, and specificity of 82.49%, 72.02%, and 82.83%, respectively. Conclusions: Our models were precise in determining image gradability and estimating CDR. Although our artificial intelligence- derived CDR estimates achieve high accuracy, the CDR threshold for glaucoma screening will vary depending on other clinical parameters. Financial Disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article. Ophthalmology Science 2024;4:100540 (c) 2024 by the American Academy of Ophthalmology. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Cup-To-Disc Ratio Measured By 20MHz B-Scan Ultrasound In The Analysis Of The Optic Nerve Head In Glaucoma
    Furlanetto, Rafael L.
    Teixeira, Sergio H.
    Prata, Tiago S.
    Allemann, Norma
    Paranhos, Augusto
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [42] Association between Genetic Variants Associated with Vertical Cup-to-Disc Ratio and Phenotypic Features of Primary Open-Angle Glaucoma
    Mabuchi, Fumihiko
    Sakurada, Yoichi
    Kashiwagi, Kenji
    Yamagata, Zentaro
    Iijima, Hiroyuki
    Tsukahara, Shigeo
    OPHTHALMOLOGY, 2012, 119 (09) : 1819 - 1825
  • [43] Genetic analysis localizes a novel locus on chromosome 4q for the glaucoma endophenotype, cup-to-disc ratio: The Jiri Eye Study
    Miller, Sarah E.
    Blackburn, Nicholas B.
    Thapa, Suman S.
    Laston, Sandra
    Kumar, Satish
    Peralta, Juan
    Subedi, Janardan
    Blangero, John
    Williams-Blangero, Sarah
    Johnson, Matthew P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [44] The Path to Open-Angle Glaucoma Gene Discovery: Endophenotypic Status of Intraocular Pressure, Cup-to-Disc Ratio, and Central Corneal Thickness
    Charlesworth, Jac
    Kramer, Patricia L.
    Dyer, Tom
    Diego, Victor
    Samples, John R.
    Craig, Jamie E.
    Mackey, David A.
    Hewitt, Alex W.
    Blangero, John
    Wirtz, Mary K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (07) : 3509 - 3514
  • [45] Optic Disc Change during Childhood Myopic Shift: Comparison between Eyes with an Enlarged Cup-To-Disc Ratio and Childhood Glaucoma Compared to Normal Myopic Eyes
    Park, Hae-Young Lopilly
    Kim, Sung Eum
    Park, Chan Kee
    PLOS ONE, 2015, 10 (07):
  • [46] Factors Associated with Large Cup-to-Disc Ratio and Blindness in the Primary Open-Angle African American Glaucoma Genetics (POAAGG) Study
    Mamidipaka, Anusha
    Di Rosa, Isabel
    Lee, Roy
    Zhu, Yan
    Chen, Yineng
    Salowe, Rebecca
    Addis, Victoria
    Sankar, Prithvi
    Daniel, Ebenezer
    Ying, Gui-Shuang
    O'Brien, Joan M.
    GENES, 2023, 14 (09)
  • [47] Accurate, fast, data efficient and interpretable glaucoma diagnosis with automated spatial analysis of the whole cup to disc profile
    MacCormick, Ian J. C.
    Williams, Bryan M.
    Zheng, Yalin
    Li, Kun
    Al-Bander, Baidaa
    Czanner, Silvester
    Cheeseman, Rob
    Willoughby, Colin E.
    Brown, Emery N.
    Spaeth, George L.
    Czanner, Gabriela
    PLOS ONE, 2019, 14 (01):
  • [48] Asian-specific vertical cup-to-disc ratio cut-off for glaucoma screening: An evidence-based recommendation from a multi-ethnic Asian population
    Soh, Zhi Da
    Chee, Miao Li
    Thakur, Sahil
    Yih Chung Tham
    Tao, Yijin
    Lim, Zhi Wei
    Mani, Baskaran
    Wong, Tina T.
    Aung, Tin
    Cheng, Ching-Yu
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 48 (09): : 1210 - 1218
  • [49] Genetic Variants Associated with Optic Nerve Vertical Cup-to-Disc Ratio Are Risk Factors for Primary Open Angle Glaucoma in a US Caucasian Population
    Fan, Bao Jian
    Wang, Dan Yi
    Pasquale, Louis R.
    Haines, Jonathan L.
    Wiggs, Janey L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (03) : 1788 - 1792
  • [50] The Path to Open Angle Glaucoma Gene Discovery Using the Endophenotypes, Intraocular Pressure, Central Corneal Thickness and Cup-To-Disc Ratio to Identify POAG-Related Loci
    Samples, J. R.
    Charlesworth, J.
    Kramer, P.
    Hewitt, A.
    Craig, J. E.
    Dyer, T.
    Mackey, D.
    Blangero, J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)