Highly Accurate and Precise Automated Cup-to-Disc Ratio Quanti fi cation for Glaucoma Screening

被引:0
|
作者
Chaurasia, Abadh K. [1 ]
Greatbatch, Connor J. [1 ]
Han, Xikun [2 ,3 ]
Gharahkhani, Puya [2 ,3 ,4 ]
Mackey, David A. [5 ]
MacGregor, Stuart [2 ,3 ]
Craig, Jamie E. [6 ]
Hewitt, Alex W. [1 ,7 ]
机构
[1] Univ Tasmania, Menzies Inst Med Res, 17 Liverpool St, Hobart, Tas 7000, Australia
[2] QIMR Berghofer Med Res Inst, Brisbane, Qld, Australia
[3] Univ Queensland, Sch Med, Brisbane, Qld, Australia
[4] Queensland Univ Technol, Sch Biomed Sci, Fac Hlth, Brisbane, Qld, Australia
[5] Univ Western Australia, Lions Eye Inst, Ctr Vis Sci, Nedlands, WA, Australia
[6] Flinders Univ S Australia, Dept Ophthalmol, Flinders Med Ctr, Bedford Pk, SA, Australia
[7] Univ Melbourne, Ctr Eye Res Australia, Melbourne, Vic, Australia
来源
OPHTHALMOLOGY SCIENCE | 2024年 / 4卷 / 05期
基金
英国医学研究理事会;
关键词
Computer Vision; Deep Learning; Glaucoma; Fundus Image; UK Biobank; OPTIC DISC; SEGMENTATION; DISCOVERY; NETWORK; SIZE;
D O I
10.1016/j.xops.2024.100540
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: An enlarged cup-to-disc ratio (CDR) is a hallmark of glaucomatous optic neuropathy. Manual assessment of the CDR may be less accurate and more time-consuming than automated methods. Here, we sought to develop and validate a deep learning- based algorithm to automatically determine the CDR from fundus images. Design: Algorithm development for estimating CDR using fundus data from a population-based observational study. Participants: A total of 181 768 fundus images from the United Kingdom Biobank (UKBB), Drishti_GS, and EyePACS. Methods: FastAI and PyTorch libraries were used to train a convolutional neural network- based model on fundus images from the UKBB. Models were constructed to determine image gradability (classification analysis) as well as to estimate CDR (regression analysis). The best-performing model was then validated for use in glaucoma screening using a multiethnic dataset from EyePACS and Drishti_GS. Main Outcome Measures: The area under the receiver operating characteristic curve and coefficient of determination. Results: Our gradability model vgg19_batch normalization (bn) achieved an accuracy of 97.13% on a validation set of 16 045 images, with 99.26% precision and area under the receiver operating characteristic curve of 96.56%. Using regression analysis, our best-performing model (trained on the vgg19_bn architecture) attained a coefficient of determination of 0.8514 (95% confidence interval [CI]: 0.8459- 0.8568), while the mean squared error was 0.0050 (95% CI: 0.0048- 0.0051) and mean absolute error was 0.0551 (95% CI: 0.0543- 0.0559) on a validation set of 12 183 images for determining CDR. The regression point was converted into classification metrics using a tolerance of 0.2 for 20 classes; the classification metrics achieved an accuracy of 99.20%. The EyePACS dataset (98 172 healthy, 3270 glaucoma) was then used to externally validate the model for glaucoma classification, with an accuracy, sensitivity, and specificity of 82.49%, 72.02%, and 82.83%, respectively. Conclusions: Our models were precise in determining image gradability and estimating CDR. Although our artificial intelligence- derived CDR estimates achieve high accuracy, the CDR threshold for glaucoma screening will vary depending on other clinical parameters. Financial Disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article. Ophthalmology Science 2024;4:100540 (c) 2024 by the American Academy of Ophthalmology. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
引用
收藏
页数:8
相关论文
共 50 条
  • [21] ARGALI- an Automatic cup-to-disc Ratio measurement system for Glaucoma detection and AnaLysIs framework
    Liu, J.
    Wong, D. W. K.
    Lim, J. H.
    Li, H.
    Tan, N. M.
    Wong, T. Y.
    MEDICAL IMAGING 2009: COMPUTER-AIDED DIAGNOSIS, 2009, 7260
  • [22] Pupil Ruff Atrophy Correlations with Intraocular Pressure and Cup-to-Disc Ratio in a Glaucoma Clinic Population
    Ang, Ghee S.
    Wong, Tracey
    Nicholas, Simon
    Wells, Anthony P.
    OPHTHALMOLOGY, 2012, 119 (08) : 1546 - 1551
  • [23] Longitudinal quantitative evaluation of cup-to-disc ratio in treated primary open-angle glaucoma
    Kim, YI
    Pereira, MLM
    Zimmerman, MB
    Montague, PR
    Alward, WLM
    Kwon, YH
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U219 - U219
  • [24] Fully automated method for glaucoma screening using robust optic nerve head detection and unsupervised segmentation based cup-to-disc ratio computation in retinal fundus images
    Mvoulana, Amed
    Kachouri, Rostom
    Akil, Mohamed
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2019, 77
  • [25] Glaucoma Screening by the Detection of Blood Vessels and Optic Cup to Disc Ratio
    Roslin, M.
    Sumathi, S.
    2016 INTERNATIONAL CONFERENCE ON COMMUNICATION AND SIGNAL PROCESSING (ICCSP), VOL. 1, 2016, : 2210 - 2214
  • [26] Aggregate Effects of Intraocular Pressure and Cup-to-Disc Ratio Genetic Variants on Glaucoma in a Multiethnic Asian Population
    Tham, Yih-Chung
    Liao, Jiemin
    Vithana, Eranga N.
    Khor, Chiea-Chuen
    Teo, Yik-Ying
    Tai, E-Shyong
    Wong, Tien Y.
    Aung, Tin
    Cheng, Ching-Yu
    OPHTHALMOLOGY, 2015, 122 (06) : 1149 - 1157
  • [27] Measurement of the human optic nerve cup-to-disc ratio with the glaucoma-scope and four clinical methods
    Hogan, SL
    Driggs, V
    Fink, BA
    Hill, RM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 5011 - 5011
  • [28] The disc damage likelihood scale: Diagnostic accuracy and correlations with cup-to-disc ratio, structural tests and standard automated perimetry
    Kara-Jose, Andrea C.
    Melo, Luiz Alberto S., Jr.
    Esporcatte, Bruno L. B.
    Endo, Angelica T. N. H.
    Leite, Mauro Toledo
    Tavares, Ivan Maynart
    PLOS ONE, 2017, 12 (07):
  • [29] Cup-to-disc ratio, intraocular pressure, and primary open-angle glaucoma in retinal venous occlusion
    Beaumont, PE
    Kang, HK
    OPHTHALMOLOGY, 2002, 109 (02) : 282 - 286
  • [30] Automated determination of cup-to-disc ratio for classification of glaucomatous and normal eyes on stereo retinal fundus images
    Muramatsu, Chisako
    Nakagawa, Toshiaki
    Sawada, Akira
    Hatanaka, Yuji
    Yamamoto, Tetsuya
    Fujita, Hiroshi
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (09)