Fibrin clot adherence on cleaned and decontaminated titanium abutment surfaces: An in vitro study

被引:0
|
作者
Ulusoy, Habibe Ozturk [1 ]
Ercan, Esra [2 ]
Ozatik, Orhan [3 ]
Tunali, Mustafa [2 ]
机构
[1] Canakkale Onsekizmart Univ, Dept Prosthodont, Canakkale, Turkiye
[2] Canakkale Onsekizmart Univ, Dept Periodontol, Canakkale, Turkiye
[3] Kutahya Hlth Sci Univ, Dept Histol & Embryol, Kutahya, Turkiye
关键词
abutments; implantology; platelet rich fibrin; SOFT-TISSUE INTEGRATION; BIOFILM FORMATION; CELL-ADHESION; IMPLANT; STERILIZATION;
D O I
10.1111/cid.13366
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of ProblemOsseointegration is now primarily established, but soft tissue integration is still susceptible to failure and problematic on implant surfaces. So, implant dentistry is increasingly focusing on improving peri-implant soft tissue integration.PurposeThe present study aimed to evaluate the blood fibrin clot formation and adhesion on the abutment after cleaning and decontamination and determine the suitable abutment surface associated with fibrin clot attachment.Materials and MethodsForty-two abutments (14 per group) were used in the present study: a brand-new (BN), contaminated with biofilm (CO) and decontaminated with an enzymatic cleaner and autoclave sterilization (DEC). For a fibrin clot, 9 mL of whole human blood and abutments was centrifuged at 2700 rpm for 12 min. Clots were divided into two parts for histomorphometry and scanning electron microscopy (SEM) analysis. Twelve abutments disconnected from the clot and two not treated with blood were observed under SEM.ResultsResidual debris and biofilm were observed on the abutment surface in the CO group but not in other groups. Healthy and organized fibrin clots formed on all abutments. The fibrin extension areas are distributed uniformly in BN and DEC groups but irregularly in CO. The surface percentage of the fibrin clot extensions was 41.76% +/- 6.73, 26.99% +/- 6.40, and 37.83% +/- 9.72 for the BN, CON, and DEC groups, respectively. The blood clot-attached areas in the CO group were statistically lower than the other groups. No difference was observed between the BN and DEC groups.ConclusionsThis study confirmed that surface contamination could influence blood clot attachment on the abutment surfaces. Cleaning and sterilization can have a favorable effect on soft tissue healing on abutment surfaces.
引用
收藏
页码:1190 / 1199
页数:10
相关论文
共 50 条
  • [41] Epithelial cell adhesion on machined and sandblasted titanium surfaces: an in vitro study.
    Vozza, I
    Quaranta, M
    Scarano, A
    Piattelli, M
    Di Carmine, M
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A186 - A186
  • [42] Biological Response of Soft Tissues to Three Abutment Materials Titanium, Zirconia, and Lithium Disilicate. An In Vitro Comparative Study
    Nicolini, M.
    Galdoporpora, J. M.
    Canellada, A.
    Macchi, R.
    Friedman, S. M.
    Guirado, J. l. Calvo
    Ibanez, J. C.
    JOURNAL OF OSSEOINTEGRATION, 2024, 16 (01) : 72 - 80
  • [43] Attachment of four Actinomyces species on titanium surfaces:: In vitro electron microscopy study.
    Sarkonen, N.
    Kononen, E.
    Lounatmaa, K.
    Kononen, M.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B361 - B361
  • [44] ANGIOGENIC FUNCTIONALISATION OF TITANIUM SURFACES USING NANO-ANCHORED VEGF - AN IN VITRO STUDY
    Schliephake, H.
    Strecker, N.
    Foerster, A.
    Schwenzer, B.
    Reichert, J.
    Scharnweber, D.
    EUROPEAN CELLS & MATERIALS, 2012, 23 : 161 - 169
  • [45] STRUT INTERLOCKING OF TITANIUM GREENFIELD VENA-CAVA FILTERS AND ITS EFFECT ON CLOT CAPTURING - AN IN-VITRO STUDY
    KORBIN, CD
    VANALLAN, RJ
    ANDREWS, RT
    KATZ, MD
    TEITELBAUM, GP
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 17 (04) : 204 - 206
  • [46] Analysis of Dimensional Changes in the Screw and the Surface Topography at the Interface of a Titanium Screw and a Zirconia Abutment Under Cyclic Loading: An In Vitro Study
    Dhingra, Ajay
    Weiner, Saul
    Luke, Allyn C.
    Ricci, John L.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (03) : 661 - 669
  • [47] Mechanical stability and technical outcomes of monolithic CAD/CAM fabricated abutment-crowns supported by titanium bases: An in vitro study
    Pitta, Joao
    Hjerppe, Jenni
    Burkhardt, Felix
    Fehmer, Vincent
    Mojon, Philippe
    Sailer, Irena
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (02) : 222 - 232
  • [48] Comparison of Shear Bond Strength for One-step Self-etch versus Universal Adhesives on Contaminated and Decontaminated Dentin Surfaces: An In-vitro Study
    Kondapaneni, Asritha
    Guptha, Anila bandlapally sreenivasa
    Vemuri, Sayesh
    Garlapati, Roopadevi
    Banu, Mayana aameena
    Halder, Niharika
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2024, 18 (12) : ZC20 - ZC24
  • [49] Parameters That Improve Cleaning Efficiency of Subgingival Air Polishing on Titanium Implant Surfaces: An In Vitro Study
    Tastepe, Ceylin S.
    Lin, Xingnan
    Donnet, Marcel
    Wismeijer, Daniel
    Liu, Yuelian
    JOURNAL OF PERIODONTOLOGY, 2017, 88 (04) : 407 - 414
  • [50] Bacterial inactivation/sterilization by argon plasma treatment on contaminated titanium implant surfaces: In vitro study
    Annunziata, Marco
    Canullo, Luigi
    Donnarumma, Giovanna
    Caputo, Pina
    Nastri, Livia
    Guida, Luigi
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2016, 21 (01): : E118 - E121