Crossflow microsand filtration in cooling tower systems to control fouling in heat exchanger devices

被引:1
|
作者
Ashok, Vaishali [1 ]
Absalan, Faezeh [1 ]
Silverwood, Alain [2 ]
Robert, Etienne [3 ]
Claveau-Mallet, Dominique [1 ]
Bedard, Emilie [1 ]
机构
[1] Polytech Montreal, Civil Geol & Min Engn Dept, Montreal, PQ, Canada
[2] Xylem Water Solut & Water Technol, Washington, DC USA
[3] Polytech Montreal, Mech Engn Dept, Montreal, PQ, Canada
来源
JOURNAL OF BUILDING ENGINEERING | 2024年 / 95卷
关键词
Side stream filtration; Building energy; HVAC; Clogging; BIOFILTRATION; CORROSION;
D O I
10.1016/j.jobe.2024.110167
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the context of global warming, there is a growing need for high-performance heat, ventilation and air conditioning systems. Fouling is a challenge, affecting heat exchanger operational and energetic performance. Side stream filtration can be used to improve water quality by reducing particle concentration in the system. The aim of this study was to assess a crossflow microsand filtration unit's efficacy in reducing fouling within an 81-plate heat exchanger, in an in-situ cooling tower circuit. A pilot heat exchanger without filtration was operated under similar conditions. After 3 years of continuous operation, visual inspection of the full-scale heat exchanger plates operating with filtration showed minimal accumulation. Pairs of facing plates (7) were scraped and rinsed to collect total solids accumulated on surfaces. Samples were resuspended and analyzed for solids and metal concentration measurements. Low average values of total volatile solids (45 mu g/cm2) and total solids (93 mu g/cm2) were indicative of a low biofilm formation. X-ray diffraction revealed the presence of calcite associated to water hardness. Low levels of iron and copper were detected despite slightly corrosive water. In contrast, the pilot heat exchanger exhibited higher deposit accumulation of total volatile solids (90 mu g/cm2) and total solids (110 mu g/cm2) after only 12 weeks of operation. These findings underscore the role of side stream filtration in reducing particle deposition and biofouling potential in full-scale cooling tower systems. Crossflow microsand filtration is a promising avenue to control fouling in building cooling tower systems, which could contribute in improving the building's energetic performance.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Optimal Sensor Selection and Fusion for Heat Exchanger Fouling Diagnosis in Aerospace Systems
    Najjar, Nayeff
    Gupta, Shalabh
    Hare, James
    Kandil, Sherif
    Walthall, Rhonda
    IEEE SENSORS JOURNAL, 2016, 16 (12) : 4866 - 4881
  • [42] Heat Exchanger Bypass Control to Mitigate the Cost of Fouling in Refinery Preheat Trains
    Diaz-Bejarano, Emilio
    Pelloja, Giulia
    Coletti, Francesco
    Macchietto, Sandro
    ICHEAP12: 12TH INTERNATIONAL CONFERENCE ON CHEMICAL & PROCESS ENGINEERING, 2015, 43 : 2119 - 2124
  • [43] Control Systems for a Heat Exchanger with Distributed Parameters
    Miron, Cristian
    Popescu, Dumitru
    Arsu, Ioana
    Olteanu, Severus
    2017 21ST INTERNATIONAL CONFERENCE ON SYSTEM THEORY, CONTROL AND COMPUTING (ICSTCC), 2017, : 518 - 523
  • [44] Fouling Mitigation on Different Heat Exchanging Surfaces Materials Used in the Hybrid Cooling Tower Test Facility
    Zaza, Afaf
    Laadel, Nour Eddine
    Agalit, Hassan
    Bennouna, El Ghali
    El Hammami, Youness
    SOLARPACES 2018: INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, 2019, 2126
  • [45] Real-time fouling characteristics of a typical heat exchanger used in the waste heat recovery systems
    Wang, Fei-Long
    He, Ya-Ling
    Tong, Zi-Xiang
    Tang, Song-Zhen
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 104 : 774 - 786
  • [46] REFRIGERATION HEAT EXCHANGER SYSTEMS FOR SERVER RACK COOLING IN DATA CENTERS
    Tsukamoto, Takeshi
    Takayoshi, Jyunji
    Schmidt, Roger R.
    Iyengar, Madhusudan K.
    IPACK 2009: PROCEEDINGS OF THE ASME INTERPACK CONFERENCE 2009, VOL 2, 2010, : 915 - 921
  • [47] Thermodynamic analyses and optimization of an auxiliary heat exchanger equipped with an absorption refrigeration system to increase the cooling capability of Heller cooling tower
    Peng, Wei
    Sadaghiani, Omid Karimi
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 25 (25)
  • [48] Use of a pilot scale heat exchanger-cooling tower system for the evaluation of mineral scale inhibitors
    Antonogiannakis, E.
    Tzagkaraki, E.
    Demadis, K. D.
    INTERNATIONAL JOURNAL OF CORROSION AND SCALE INHIBITION, 2013, 2 (04): : 255 - 268
  • [49] Dehumidification behavior of an aluminophosphate zeolite coated crossflow heat exchanger driven with direct hot water heating and evaporative cooling
    Sunhor, Seng
    Osaka, Yugo
    Tsujiguchi, Takuya
    Kodama, Akio
    Saputra, Dendi Adi
    APPLIED THERMAL ENGINEERING, 2022, 210
  • [50] Online Integration of Optimal Cleaning Scheduling and Control of Heat Exchanger Networks under Fouling
    Santamaria, Federico Lozano
    Macchietto, Sandro
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2020, 59 (06) : 2471 - 2490