Explore the feasibility of using spot-scanning proton arc therapy for a synchrotron accelerator-based proton therapy system - A simulation study

被引:0
|
作者
Cong, Xiaoda [1 ]
Liu, Gang [2 ]
Liu, Peilin [1 ]
Zhao, Lewei [3 ]
Chen, Shupeng [1 ]
Li, Xiaoqiang [1 ]
Shen, Jiajian [4 ]
Ding, Xuanfeng [1 ]
机构
[1] Corewell Hlth William Beaumont Univ Hosp, Dept Radiat Oncol, Royal Oak, MI 48073 USA
[2] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Canc Ctr, Wuhan, Peoples R China
[3] Stanford Univ, Dept Radiat Oncol, Stanford, CA USA
[4] Mayo Clin, Dept Radiat Oncol, Phoenix, AZ 85054 USA
来源
关键词
intensity-modulated proton therapy; spot scanning proton arc therapy; synchrotron-accelerator; DELIVERY-EFFICIENT; SPARC THERAPY; BEAM; ROBUST;
D O I
10.1002/acm2.14526
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of this study was to evaluate the feasibility and plan quality of spot-scanning proton arc therapy (SPArc) using a synchrotron-accelerator- based proton therapy system compared to intensity-modulated proton therapy (IMPT). Approach: Five representative disease sites, including head and neck, lung, liver, brain chordoma, and prostate cancers, were retrospectively selected. Both IMPT and SPArc plans are generated with the HITACHI ProBEAT PBS system's minimum MU constraints and physics beam model. The SPArc plans are generated with 2.5 degrees degrees sampling frequency. The static delivery time was simulated based on the previously published synchrotron delivery sequence model, and the dynamic delivery time was simulated using a proton arc gantry mechanical model integrated with the synchrotron delivery sequence. Both dosimetric plan quality and delivery efficiency are evaluated. Main results: A superior plan quality is reached compared with the IMPT plans generated for the same disease site. However, a relatively prolonged static and dynamic delivery time post new challenge, as static time increased by 49.22% and dynamic time 59.10% on average. Significance: This study presents the first simulation results of delivering the SPArc plans using a synchrotron-accelerated proton therapy system. The result shows its feasibility and limitations, which could guide future development.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] A dynamic collimation system for penumbra reduction in spot-scanning proton therapy: Proof of concept
    Hyer, Daniel E.
    Hill, Patrick M.
    Wang, Dongxu
    Smith, Blake R.
    Flynn, Ryan T.
    MEDICAL PHYSICS, 2014, 41 (09)
  • [42] Active spot-scanning proton therapy for intracranial meningiomas: CNAO experience
    D'Ippolito, E.
    Iannalfi, A.
    Bonora, M.
    Vischioni, B.
    Fiore, M. R.
    Ronchi, S.
    Vitolo, V.
    Barcellini, A.
    Petrucci, R.
    Mirandola, A.
    Maestri, D.
    Magro, G.
    Facoetti, A.
    Viselner, G.
    Ciocca, M.
    Preda, L.
    Valvo, F.
    Orecchia, R.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S380 - S381
  • [43] Analysis of the Rate of Re-planning in Spot-Scanning Proton Therapy
    Hu, Yue-Houng
    Harper, Riley H.
    Deiter, Noelle C.
    Evans, Jaden D.
    Mahajan, Anita
    Kruse, Jon J.
    Mundy, Daniel W.
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2022, 9 (02) : 49 - 58
  • [44] First Feasibility study: Spot-scanning Proton Arc Stereotactic Radiosurgery (SRS) for Localized Spine Metastasis
    Zhou, J.
    Kabolizadeh, P.
    Grills, I. S.
    Li, X.
    Wang, Y.
    Yan, D.
    Ding, X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E747 - E747
  • [45] Investigating the Influence of Spot Error on Plan Quality: A Comparative Study of Spot-Scanning Arc Therapy (SPArc) and Intensity-Modulated Proton Therapy (IMPT)
    Liu, P.
    Zhao, L.
    Liu, G.
    Cong, X.
    Li, X.
    Ding, X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E158 - E158
  • [46] Dosimetric Evaluation of Target Motion Effects in Spot-Scanning Proton Therapy: A Phantom Study
    Belikhin, Mikhail
    Shemyakov, Alexander
    Chernyaev, Alexander
    Pryanichnikov, Alexander
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2024, 11
  • [47] Improving dosimetric outcome for hippocampus and cochlea sparing whole brain radiotherapy using spot-scanning proton arc therapy
    Ding, Xuanfeng
    Zhou, Jun
    Li, Xiaoqiang
    Blas, Kevin
    Liu, Gang
    Wang, Yinan
    Qin, An
    Chinnaiyan, Prakash
    Yan, Di
    Stevens, Craig
    Grills, Inga
    Kabolizadeh, Peyman
    ACTA ONCOLOGICA, 2019, 58 (04) : 483 - 490
  • [48] A simulation study on the dosimetric benefit of real-time motion compensation in spot-scanning proton therapy for prostate
    Proton Beam Therapy Center, Hokkaido University Hospital, Kita 14 Nishi 5, Sapporo
    060-8648, Japan
    不详
    060-8648, Japan
    不详
    060-8628, Japan
    不详
    060-8648, Japan
    不详
    060-8638, Japan
    J. Rad. Res., 4 (591-597):
  • [49] A simulation study on the dosimetric benefit of real-time motion compensation in spot-scanning proton therapy for prostate
    Fujii, Yusuke
    Matsuura, Taeko
    Takao, Seishin
    Matsuzaki, Yuka
    Fujii, Takaaki
    Miyamoto, Naoki
    Umegaki, Kikuo
    Nishioka, Kentaro
    Shimizu, Shinichi
    Shirato, Hiroki
    JOURNAL OF RADIATION RESEARCH, 2017, 58 (04) : 591 - 597
  • [50] Mitigation of Dosimetric Uncertainty in MRI-Based Proton Planning Using Spot-Scanning Proton Arc (SPArc) Technique
    Peng, Y.
    Chen, S.
    Liu, Y.
    Zhao, L.
    Liu, P.
    An, Q.
    Zhao, C.
    Deng, X.
    Deraniyagala, R. L., Jr.
    Stevens, C. W.
    Ding, X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E614 - E615