A dynamic collimation system for penumbra reduction in spot-scanning proton therapy: Proof of concept

被引:68
|
作者
Hyer, Daniel E. [1 ]
Hill, Patrick M. [1 ]
Wang, Dongxu [1 ]
Smith, Blake R. [1 ]
Flynn, Ryan T. [1 ]
机构
[1] Univ Iowa, Dept Radiat Oncol, Iowa City, IA 52242 USA
关键词
intensity modulated proton therapy (IMPT); spot scanning; protons; penumbra; collimation; RADIOTHERAPY; BEAM;
D O I
10.1118/1.4837155
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In the absence of a collimation system the lateral penumbra of spot scanning (SS) dose distributions delivered by low energy proton beams is highly dependent on the spot size. For current commercial equipment, spot size increases with decreasing proton energy thereby reducing the benefit of the SS technique. This paper presents a dynamic collimation system (DCS) for sharpening the lateral penumbra of proton therapy dose distributions delivered by SS. Methods: The collimation system presented here exploits the property that a proton pencil beam used for SS requires collimation only when it is near the target edge, enabling the use of trimmers that are in motion at times when the pencil beam is away from the target edge. The device consists of two pairs of parallel nickel trimmer blades of 2 cm thickness and dimensions of 2 cm x 18 cm in the beam's eye view. The two pairs of trimmer blades are rotated 90 degrees relative to each other to form a rectangular shape. Each trimmer blade is capable of rapid motion in the direction perpendicular to the central beam axis by means of a linear motor, with maximum velocity and acceleration of 2.5 m/s and 19.6m/s(2), respectively. The blades travel on curved tracks to match the divergence of the proton source. An algorithm for selecting blade positions is developed to minimize the dose delivered outside of the target, and treatment plans are created both with and without the DCS. Results: The snout of the DCS has outer dimensions of 22.6 x 22.6 cm(2) and is capable of delivering a minimum treatment field size of 15 x 15 cm(2). Using currently available components, the constructed system would weigh less than 20 kg. For irregularly shaped fields, the use of the DCS reduces the mean dose outside of a 2D target of 46.6 cm(2) by approximately 40% as compared to an identical plan without collimation. The use of the DCS increased treatment time by 1-3 s per energy layer. Conclusions: The spread of the lateral penumbra of low-energy SS proton treatments may be greatly reduced with the use of this system at the cost of only a small penalty in delivery time. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Effects of spot size and spot spacing on lateral penumbra reduction when using a dynamic collimation system for spot scanning proton therapy
    Hyer, Daniel E.
    Hill, Patrick M.
    Wang, Dongxu
    Smith, Blake R.
    Flynn, Ryan T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22): : N187 - N196
  • [2] From Concept to First Delivery of the Spot-Scanning Proton Arc Therapy
    Li, X.
    Liu, G.
    Janssens, G.
    De Wilde, O.
    Bossier, V.
    Lerot, X.
    Pouppez, A.
    Yan, D.
    Stevens, C.
    Kabolizadeh, P.
    Ding, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E290 - E290
  • [3] Spot-Scanning Proton Arc (SPArc) Therapy: The First Robust and Delivery-Efficient Spot-Scanning Proton Arc Therapy
    Ding, Xuanfeng
    Li, Xiaoqiang
    Zhang, J. Michele
    Kabolizadeh, Peyman
    Stevens, Craig
    Yan, Di
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (05): : 1107 - 1116
  • [4] A scanning dynamic collimator for spot-scanning proton minibeam production
    Marios Sotiropoulos
    Yolanda Prezado
    Scientific Reports, 11
  • [5] A scanning dynamic collimator for spot-scanning proton minibeam production
    Sotiropoulos, Marios
    Prezado, Yolanda
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [6] Quantifying lateral penumbra advantages of collimated spot-scanning beam for intensity-modulated proton therapy
    Chun-Bo Liu
    Yun-Tao Song
    Hong-Dong Liu
    Hai-Zhou Xue
    Han-Sheng Feng
    NuclearScienceandTechniques, 2019, 30 (11) : 54 - 61
  • [7] Quantifying lateral penumbra advantages of collimated spot-scanning beam for intensity-modulated proton therapy
    Chun-Bo Liu
    Yun-Tao Song
    Hong-Dong Liu
    Hai-Zhou Xue
    Han-Sheng Feng
    Nuclear Science and Techniques, 2019, 30
  • [8] Quantifying lateral penumbra advantages of collimated spot-scanning beam for intensity-modulated proton therapy
    Liu, Chun-Bo
    Song, Yun-Tao
    Liu, Hong-Dong
    Xue, Hai-Zhou
    Feng, Han-Sheng
    NUCLEAR SCIENCE AND TECHNIQUES, 2019, 30 (11)
  • [9] Beam commissioning of the first compact proton therapy system with spot scanning and dynamic field collimation
    Vilches-Freixas, Gloria
    Unipan, Mirko
    Rinaldi, Ilaria
    Martens, Jonathan
    Roijen, Erik
    Almeida, Isabel P.
    Decabooter, Esther
    Bosmans, Geert
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1107):
  • [10] A Dynamic Collimation System for Spot Scanning Proton Therapy: Design and Potential Benefits for Brain Treatments
    Hyer, D.
    Wang, D.
    Moignier, A.
    Gelover, E.
    Lin, L.
    Kirk, M. L.
    Solberg, T. D.
    Flynn, R. T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E574 - E575