An Eulerian formulation for the computational modeling of phase-contrast MRI

被引:0
|
作者
Otani, Tomohiro [1 ]
Sekine, Tetsuro [2 ]
Sato, Yu [1 ]
Alves, Ellen Cavalcante [1 ]
Wada, Shigeo [1 ]
机构
[1] Osaka Univ, Dept Mech Sci & Bioengn, Grad Sch Engn Sci, 1-3 Machikaneyamacho, Toyonaka, Osaka 5608531, Japan
[2] Kosugi Hosp, Nippon Med Sch Musashi, Dept Radiol, Kawasaki, Kanagawa, Japan
基金
日本学术振兴会;
关键词
Eulerian formulation; high-performance computing; modified Bloch equation; phase-contrast MRI; BLOCH EQUATIONS; NUMERICAL-SIMULATION; CAROTID BIFURCATION; FLOW; DIFFUSION;
D O I
10.1002/mrm.30302
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Computational simulation of phase-contrast MRI (PC-MRI) is an attractive way to physically interpret properties and errors in MRI-reconstructed flow velocity fields. Recent studies have developed PC-MRI simulators that solve the Bloch equation, with the magnetization transport being modeled using a Lagrangian approach. Because this method expresses the magnetization as spatial distribution of particles, influences of particle densities and their spatial uniformities on numerical accuracy are well known. This study developed an alternative method for PC-MRI modeling using an Eulerian approach in which the magnetization is expressed as a spatially smooth continuous function. Methods: The magnetization motion was described using the Bloch equation with an advection term and computed on a fixed grid using a finite difference method, and k-space sampling was implemented using the spoiled gradient echo sequence. PC-MRI scans of a fully developed flow in straight and stenosed cylinders were acquired to provide numerical examples. Results: Reconstructed flow in a straight cylinder showed excellent agreement with input velocity profiles and mean errors were less than 0.5% of the maximum velocity. Numerical cases of flow in a stenosed cylinder successfully demonstrated the velocity profiles, with displacement artifacts being dependent on scan parameters and intravoxel dephasing due to flow disturbances. These results were in good agreement with those obtained using the Lagrangian approach with a sufficient particle density. Conclusion: The feasibility of the Eulerian approach to PC-MRI modeling was successfully demonstrated.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] The Role of Phase-Contrast MRI in Diagnosing Cerebrospinal Fluid Flow Abnormalities
    Govindarajan, B. R.
    Sharma, Praveen K.
    Polaka, Yashaswinii
    Pujitha, S.
    Natarajan, Paarthipan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [42] DEVELOPMENT OF A METHODOLOGY FOR DIRECT UTILIZATION OF PHASE-CONTRAST MRI IN HEMODYNAMIC COMPUTATIONS
    Das, Ashish
    Gottliebson, William M.
    Wansapura, Janaka
    Banerjee, Rupak K.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2011, PTS A AND B, 2011, : 1135 - 1136
  • [43] Bayesian Motion Recovery Framework for Myocardial Phase-Contrast Velocity MRI
    Huntbatch, Andrew
    Lee, Su-Lin
    Firmin, David
    Yang, Guang-Zhong
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT II, PROCEEDINGS, 2008, 5242 : 79 - 86
  • [44] Time-resolved three-dimensional phase-contrast MRI
    Markl, M
    Chan, FP
    Alley, MT
    Wedding, KL
    Draney, MT
    Elkins, CJ
    Parker, DW
    Wicker, R
    Taylor, CA
    Herfkens, RJ
    Pelc, NJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (04) : 499 - 506
  • [45] Phase-contrast microscope with molecular contrast
    Toda, Keiichiro
    Tamamitsu, Miu
    Horisaki, Ryoichi
    Ideguchi, Takuro
    2019 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE & EUROPEAN QUANTUM ELECTRONICS CONFERENCE (CLEO/EUROPE-EQEC), 2019,
  • [46] Phase-contrast MRI and CFD modeling of apparent 3He gas flow in rat pulmonary airways
    Minard, Kevin R.
    Kuprat, Andrew P.
    Kabilan, Senthil
    Jacob, Richard E.
    Einstein, Daniel R.
    Carson, James P.
    Corley, Richard A.
    JOURNAL OF MAGNETIC RESONANCE, 2012, 221 : 129 - 138
  • [47] QUANTITATIVE HEMODYNAMIC COMPARISON OF VELOCITY VALUES FROM COMPUTATIONAL FLUID DYNAMICS AND PHASE-CONTRAST MRI IN AN IN-VITRO ANEURYSM MODEL
    George, Stephanie M.
    Cao, Amos
    Giddens, Don P.
    Oshinski, John N.
    Tong, Frank C.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 99 - 100
  • [48] Phase-Contrast MRI Detection of Ventricular Shunt CSF Flow: Proof of Principle
    Koenig, Rebecca E.
    Stucht, Daniel
    Baecke, Sebastian
    Rashidi, Ali
    Speck, Oliver
    Sandalcioglu, I. Erol
    Luchtmann, Michael
    JOURNAL OF NEUROIMAGING, 2020, 30 (06) : 746 - 753
  • [49] ON THE INTERPRETATION OF PHASE-CONTRAST IMAGES
    STEEL, WH
    TCHAN, YT
    QUARTERLY JOURNAL OF MICROSCOPICAL SCIENCE, 1960, 101 (04): : 465 - 473
  • [50] PHASE-CONTRAST MICROSCOPY OF VIRUSES
    BARER, R