摘要
Purpose: Computational simulation of phase-contrast MRI (PC-MRI) is an attractive way to physically interpret properties and errors in MRI-reconstructed flow velocity fields. Recent studies have developed PC-MRI simulators that solve the Bloch equation, with the magnetization transport being modeled using a Lagrangian approach. Because this method expresses the magnetization as spatial distribution of particles, influences of particle densities and their spatial uniformities on numerical accuracy are well known. This study developed an alternative method for PC-MRI modeling using an Eulerian approach in which the magnetization is expressed as a spatially smooth continuous function. Methods: The magnetization motion was described using the Bloch equation with an advection term and computed on a fixed grid using a finite difference method, and k-space sampling was implemented using the spoiled gradient echo sequence. PC-MRI scans of a fully developed flow in straight and stenosed cylinders were acquired to provide numerical examples. Results: Reconstructed flow in a straight cylinder showed excellent agreement with input velocity profiles and mean errors were less than 0.5% of the maximum velocity. Numerical cases of flow in a stenosed cylinder successfully demonstrated the velocity profiles, with displacement artifacts being dependent on scan parameters and intravoxel dephasing due to flow disturbances. These results were in good agreement with those obtained using the Lagrangian approach with a sufficient particle density. Conclusion: The feasibility of the Eulerian approach to PC-MRI modeling was successfully demonstrated.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] A phase-contrast MRI study of physiologic cerebral venous flow
    Stoquart-ElSankari, Souraya
    Lehmann, Pierre
    Villette, Agnes
    Czosnyka, Marek
    Meyer, Marc-Etienne
    Deramond, Herve
    Baledent, Olivier
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2009, 29 (06): : 1208 - 1215
  • [22] ICP Monitoring and Phase-Contrast MRI to Investigate Intracranial Compliance
    Lokossou, A.
    Baledent, O.
    Garnotel, S.
    Page, G.
    Balardy, L.
    Czosnyka, Z.
    Payoux, P.
    Schmidt, E. A.
    INTRACRANIAL PRESSURE & NEUROMONITORING XVI, 2018, 126 : 247 - 253
  • [23] Spatiotemporal Phase Unwrapping for Real-Time Phase-Contrast Flow MRI
    Untenberger, Markus
    Huellebrand, Markus
    Tautz, Lennart
    Joseph, Arun A.
    Voit, Dirk
    Merboldt, K. Dietmar
    Frahm, Jens
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (04) : 964 - 970
  • [24] PHASE-CONTRAST MICROSCOPY
    不详
    LANCET, 1946, 251 (DEC7): : 838 - 838
  • [25] PHASE-CONTRAST HOLOGRAMS
    ROGERS, GL
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1965, 55 (09) : 1181 - +
  • [26] Phase-contrast radiography
    Gao, DC
    Pogany, A
    Stevenson, AW
    Wilkins, SW
    RADIOGRAPHICS, 1998, 18 (05) : 1257 - 1267
  • [27] Velocity of cerebrospinal fluid in the aqueduct measured by phase-contrast MRI in rat
    Ding, Guangliang
    Li, Lian
    Chopp, Michael
    Zhang, Li
    Li, Qingjiang
    Luo, Hao
    Wei, Min
    Zhang, Jing
    Boyd, Edward
    Zhang, Zhenggang
    Jiang, Quan
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [28] Highly k-t-Space-Accelerated Phase-Contrast MRI
    Jung, Bernd
    Honal, Matthias
    Ullmann, Peter
    Hennig, Juergen
    Markl, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (05) : 1169 - 1177
  • [29] Aortopulmonary collateral flow in cystic fibrosis assessed with phase-contrast MRI
    Fleck, Robert
    McPhail, Gary
    Szczesniak, Rhonda
    Knowlton, Joshua
    Radhakrishnan, Rupa
    Clancy, John
    Amin, Raouf
    PEDIATRIC RADIOLOGY, 2013, 43 (10) : 1279 - 1286
  • [30] Flow-gated phase-contrast MRI using radial acquisitions
    Thompson, RB
    McVeigh, ER
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (03) : 598 - 604