An Eulerian formulation for the computational modeling of phase-contrast MRI

被引:0
|
作者
Otani, Tomohiro [1 ]
Sekine, Tetsuro [2 ]
Sato, Yu [1 ]
Alves, Ellen Cavalcante [1 ]
Wada, Shigeo [1 ]
机构
[1] Osaka Univ, Dept Mech Sci & Bioengn, Grad Sch Engn Sci, 1-3 Machikaneyamacho, Toyonaka, Osaka 5608531, Japan
[2] Kosugi Hosp, Nippon Med Sch Musashi, Dept Radiol, Kawasaki, Kanagawa, Japan
基金
日本学术振兴会;
关键词
Eulerian formulation; high-performance computing; modified Bloch equation; phase-contrast MRI; BLOCH EQUATIONS; NUMERICAL-SIMULATION; CAROTID BIFURCATION; FLOW; DIFFUSION;
D O I
10.1002/mrm.30302
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Computational simulation of phase-contrast MRI (PC-MRI) is an attractive way to physically interpret properties and errors in MRI-reconstructed flow velocity fields. Recent studies have developed PC-MRI simulators that solve the Bloch equation, with the magnetization transport being modeled using a Lagrangian approach. Because this method expresses the magnetization as spatial distribution of particles, influences of particle densities and their spatial uniformities on numerical accuracy are well known. This study developed an alternative method for PC-MRI modeling using an Eulerian approach in which the magnetization is expressed as a spatially smooth continuous function. Methods: The magnetization motion was described using the Bloch equation with an advection term and computed on a fixed grid using a finite difference method, and k-space sampling was implemented using the spoiled gradient echo sequence. PC-MRI scans of a fully developed flow in straight and stenosed cylinders were acquired to provide numerical examples. Results: Reconstructed flow in a straight cylinder showed excellent agreement with input velocity profiles and mean errors were less than 0.5% of the maximum velocity. Numerical cases of flow in a stenosed cylinder successfully demonstrated the velocity profiles, with displacement artifacts being dependent on scan parameters and intravoxel dephasing due to flow disturbances. These results were in good agreement with those obtained using the Lagrangian approach with a sufficient particle density. Conclusion: The feasibility of the Eulerian approach to PC-MRI modeling was successfully demonstrated.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] An Eulerian formulation for the computational modeling of phase-contrast MRI
    Otani, Tomohiro
    Sekine, Tetsuro
    Sato, Yu
    Alves, Ellen Cavalcante
    Wada, Shigeo
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (02) : 828 - 841
  • [2] Velocity Variability in MRI Phase-Contrast
    Firoozabadi, Ali Dehghan
    Irarrazaval, Pablo
    Uribe, Sergio
    Tejos, Cristian
    Sing-Long, Carlos
    2018 26TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2018, : 31 - 35
  • [3] Cardiovascular Applications of Phase-Contrast MRI
    Srichai, Monvadi B.
    Lim, Ruth P.
    Wong, Samson
    Lee, Vivian S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (03) : 662 - 675
  • [4] Noise estimation for the velocity in MRI phase-contrast
    Irarrazaval, Pablo
    Dehghan Firoozabadi, Ali
    Uribe, Sergio
    Tejos, Cristian
    Sing-Long, Carlos
    MAGNETIC RESONANCE IMAGING, 2019, 63 : 250 - 257
  • [5] ACCELERATED PHASE-CONTRAST FLOW MRI WITH LOW-RANK AND GENERATIVE SUBSPACE MODELING
    Lu, Hengfa
    Sun, Aiqi
    Wang, Jiachen
    Zhao, Bo
    FIFTY-SEVENTH ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS & COMPUTERS, IEEECONF, 2023, : 27 - 31
  • [6] A Bayesian Model for Highly Accelerated Phase-Contrast MRI
    Rich, Adam
    Potter, Lee C.
    Jin, Ning
    Ash, Joshua
    Simonetti, Orlando P.
    Ahmad, Rizwan
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (02) : 689 - 701
  • [7] Phase-contrast MRI and applications in congenital heart disease
    Goldberg, A.
    Jha, S.
    CLINICAL RADIOLOGY, 2012, 67 (05) : 399 - 410
  • [8] Phase-Contrast MRI: Physics, Techniques, and Clinical Applications
    Wymer, David T.
    Patel, Kunal P.
    Burke, William F., III
    Bhatia, Vinay K.
    RADIOGRAPHICS, 2020, 40 (01) : 122 - 140
  • [9] Chemical shift-induced phase errors in phase-contrast MRI
    Middione, Matthew J.
    Ennis, Daniel B.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (02) : 391 - 401
  • [10] Phase-space formulation for phase-contrast x-ray imaging
    Wu, XZ
    Liu, H
    APPLIED OPTICS, 2005, 44 (28) : 5847 - 5854