Sulphur hexafluoride in modern medium-voltage switchgear: Advantages, hazards and environmental impact

被引:0
|
作者
Boskovic, Aleksandar [1 ]
Sremacki, Maja [1 ]
Vjestica, Suncica [2 ]
Cavic, Aleksandra [3 ]
Markovic, Nada [1 ]
Borovac, Branislav [1 ]
机构
[1] Univ Novi Sad, Fac Tech Sci, Trg Dositeja Obradovica 6, Novi Sad 21000, Serbia
[2] Metropolitan Univ, Fac Appl Ecol Futura, Pozeska 83a, Belgrade 11000, Serbia
[3] FIMEK, Fac Econ & Engn Management, Cvecarska 2, Novi Sad 21000, Serbia
关键词
greenhouse gas; switching device; persistence; toxicity; ALOHA (R) software; SF6; DECOMPOSITION; FLUORIDE;
D O I
10.2298/JSC231203008B
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Sulphur hexafluoride is synthesised as a persistent and non-toxic gas with an exceptional dielectric strength. In contemporary medium-voltage switchgear within power distribution systems, SF6 gas is used for the insulation and the extinction of electric arc. The application of SF6 has advantages in terms of gas physicochemical characteristics and performance; the dimensions, the cost-effectiveness, the reliability of the switchgear equipment and the duration, as well as the cost of maintenance were significantly reduced. SF6 is a known greenhouse gas, which tends to accumulate in the lungs, inducing oxygen depletion and respiratory complications. The by-products of SF6 formed during the electric arc can be harmful and toxic. The equipment containing SF6 is being replaced in the EU and worldwide. Using ALOHA (R) software the scenarios of leakage for SF6 and by-products were modelled in urban areas, where the switchgear is frequently placed. In areas where the circulation of wind is lower (urban areas), in hazardous situations, it is not possible to depend on high dispersion levels or minimisation of concentration and threat. The models have shown that SF6 poses an environmental problem and its by-products cause a serious health hazard in the case of leakage in urban areas, rendering red threat zones from 10 to 60 m in radius.
引用
收藏
页码:693 / 704
页数:12
相关论文
共 50 条
  • [1] Impact of Arc Flash Hazards on Medium-Voltage Switchgear
    Shah, Kanu R.
    Cinsavich, Alan L.
    De Silva, Priyan
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2008, 44 (06) : 1859 - 1863
  • [2] MEDIUM-VOLTAGE SWITCHGEAR CUBICLES
    POOLE, D
    MUNZINGER, K
    BROWN BOVERI REVIEW, 1984, 71 (1-2): : 54 - 61
  • [3] Impact of Arc Flash Hazards on Medium Voltage Switchgear
    Shah, K. R.
    Cinsavich, A.
    De Silva, P.
    CONFERENCE RECORD OF THE 2007 IEEE INDUSTRY APPLICATIONS CONFERENCE FORTY-SECOND IAS ANNUAL MEETING, VOLS. 1-5, 2007, : 2128 - 2132
  • [4] A NEW GENERATION OF MEDIUM-VOLTAGE SWITCHGEAR
    HOYER, P
    KRAMER, W
    BROWN BOVERI REVIEW, 1985, 72 (01): : 24 - 28
  • [5] DEVELOPMENT TRENDS IN MEDIUM-VOLTAGE SWITCHGEAR
    PAULS, H
    HACKENSCHMIDT, K
    BROWN BOVERI REVIEW, 1986, 73 (11): : 621 - 628
  • [6] Recent topics of the medium-voltage switchgear in Japan
    Morita, Ayumu
    Proceedings of the IEEE Power Engineering Society Transmission and Distribution Conference, 2002, 2 (ASIA PACIFIC): : 1450 - 1454
  • [7] ALTERNATIVE INSULATION GAS FOR MEDIUM-VOLTAGE SWITCHGEAR
    Hyrenbach, Maik
    Zache, Sebastian
    2016 PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE EUROPE (PCIC EUROPE), 2016,
  • [8] Recent topics of the medium-voltage switchgear in Japan
    Morita, A
    IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 1450 - 1454
  • [9] Delivery time shortened for versatile medium-voltage switchgear
    Anon
    Plant Engineer (London), 2002, 46 (05):
  • [10] New approaches for maintenance grounding in medium-voltage switchgear
    Richard, Joe
    Mabius, David
    Iron and Steel Technology, 2013, 10 (09): : 71 - 78