Transfer accuracy of 3D printed versus CAD/CAM milled surgical guides for temporary orthodontic implants: A preclinical micro CT study

被引:0
|
作者
Schwarzler, Alexander [1 ]
Ludwig, Bjoern [2 ]
Chitan, Patrick [1 ]
Lettner, Stefan [3 ,4 ]
Sagl, Benedikt [5 ]
Jonke, Erwin [1 ]
机构
[1] Med Univ Vienna, Univ Clin Dent, Dept Orthodont, Vienna, Austria
[2] Saarland Univ, Dept Orthodont, Saar, Germany
[3] Med Univ Vienna, Univ Clin Dent, Karl Donath Lab Hard Tissue & Biomat Res, Vienna, Austria
[4] Austrian Cluster Tissue Regenerat, Vienna, Austria
[5] Med Univ Vienna, Univ Clin Dent, Ctr Clin Res, Vienna, Austria
关键词
Digital dentistry; Temporary anchorage devices; Guided implantation; CAD/CAM; Dental milling; Medical 3D printing; SKELETAL; INSERTION;
D O I
10.1016/j.jdent.2024.105060
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Temporary anchorage devices (TADs) have become an integral part of comprehensive orthodontic treatments. This study evaluated the transfer accuracy of three-dimensional (3D) printed and computer-aided design/computer-aided manufacturing (CAD/CAM) milled surgical guides for orthodontic TADs using micro- computed tomography (CT) imaging in a preclinical trial. Methods: Overall, 30 surgical guides were used to place TADs into typodonts; 3D printing and CAD/CAM milling were used to produce the guides. The virtual target positions of the TADs were compared to the real positions in terms of spatial and angular deviations using digital superimposition. Micro-CT imaging was used to detect the positions. To evaluate reliability, two investigators collected the measurements twice. Intra-rater and inter-rater correlations were tested. Results: In total, 60 palatal TADs were evaluated. The mean coronal deviations in the print group ranged from 0.15 f 0.20 mm to 0.71 f 0.22 mm, whereas in the mill group, they ranged from 0.09 f 0.15 mm to 0.83 f 0.23 mm. At the apical tip, the overall deviations in the print group ranged from 0.14 f 0.56 mm to 1.27 f 0.66 mm, whereas in the mill group, they ranged from 0.15 f 0.57 mm to 1.09 f 0.44 mm. The mean intra-class and interclass correlation coefficients ranged from 0.904 to 0.987. No statistically significant differences were found between the groups. Conclusions: CAD/CAM milled guides yielded spatial and angular accuracies comparable to those of 3D printed guides with notable deviations in the vertical positioning of TADs. Clinical significance: Digital planning of orthodontic temporary implants combines clinical predictability and the safety of surrounding tissue. Therefore, the transfer accuracy of the guides is crucial. This preclinical study was the first to evaluate CAD/CAM milling for orthodontic guides and found its accuracy comparable to that of the current "gold standard".
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Accuracy of Implants Placed with Surgical Guides: Thermoplastic Versus 3D Printed
    Bell, Caitlyn K.
    Sahl, Erik F.
    Kim, Yoon Jeong
    Rice, Dwight D.
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2018, 38 (01) : 113 - 120
  • [2] Accuracy of palatal orthodontic mini-implants placed by conventionally or CAD/CAM-based surgical guides: a comparative in vitro study
    de la Rosa, Maria R. Mang
    Safaltin, Ayse
    Jost-Brinkmann, Paul -Georg
    Aigner, Annette
    Koch, Petra Julia
    ANGLE ORTHODONTIST, 2023, 93 (01) : 79 - 87
  • [3] Comparative Analysis between Conventional Acrylic, CAD/CAM Milled, and 3D CAD/CAM Printed Occlusal Splints
    Abad-Coronel, Cristian
    Ruano Espinosa, Carolina
    Ordonez Palacios, Sofia
    Paltan, Cesar A.
    Fajardo, Jorge I.
    MATERIALS, 2023, 16 (18)
  • [4] Comparison of the accuracy of implants placed with CAD-CAM surgical templates manufactured with various 3D printers: An in vitro study
    Herschdorfer, Laura
    Negreiros, William Matthew
    Gallucci, German O.
    Hamilton, Adam
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (06): : 905 - 910
  • [5] Accuracy of 3D printed polymers intended for models and surgical guides printed with two different 3D printers
    Johansson, Camilla
    Dibes, Jasmin
    Rodriguez, Luis Emilio Lopez
    Papia, Evaggelia
    DENTAL MATERIALS JOURNAL, 2021, 40 (02) : 339 - 347
  • [6] Effect of Steam Heat Sterilization on the Accuracy of 3D Printed Surgical Guides
    Marei, Hesham F.
    Alshaia, Alaa
    Alarifi, Sundus
    Almasoud, Nail
    Abdelhady, Adel
    IMPLANT DENTISTRY, 2019, 28 (04) : 372 - 377
  • [7] Wear of 3D printed and CAD/CAM milled interim resin materials after chewing simulation
    Myagmar, Gerelmaa
    Lee, Jae-Hyun
    Ahn, Jin-Soo
    Yeo, In-Sung Luke
    Yoon, Hyung-In
    Han, Jung-Suk
    JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (03): : 144 - 151
  • [8] Accuracy of Two Variants of 3D-Printed Insertion Guides for Orthodontic Mini-Implants: An Ex Vivo Study in Human Cadavers
    Pliska, Annika
    Schiavon, Lucia
    Brunello, Giulia
    Wilmes, Benedict
    Schwarz-Herzke, Beryl
    Drescher, Dieter
    Becker, Kathrin
    APPLIED SCIENCES-BASEL, 2023, 13 (16):
  • [9] Color Stability Determination of CAD/CAM Milled and 3D Printed Acrylic Resins for Denture Bases: A Narrative Review
    Dimitrova, Mariya
    Corsalini, Massimo
    Kazakova, Rada
    Vlahova, Angelina
    Barile, Giuseppe
    Dell'Olio, Fabio
    Tomova, Zlatina
    Kazakov, Stoyan
    Capodiferro, Saverio
    JOURNAL OF COMPOSITES SCIENCE, 2022, 6 (07):
  • [10] In vitro evaluation of the mechanical and optical properties of 3D printed vs CAD/CAM milled denture teeth materials
    Abdelfattah, Mohamed Y.
    Al Humayyani, Nouf
    Alwthinani, Fahad K.
    Alzahrani, Abdulrahman H.
    Alotaibi, Abdulmajeed O.
    Yousef, Mohamed
    Ahmed, Akram Sayed
    Ali, Ahmed
    SAUDI DENTAL JOURNAL, 2024, 36 (09) : 1227 - 1232