Transfer accuracy of 3D printed versus CAD/CAM milled surgical guides for temporary orthodontic implants: A preclinical micro CT study

被引:0
|
作者
Schwarzler, Alexander [1 ]
Ludwig, Bjoern [2 ]
Chitan, Patrick [1 ]
Lettner, Stefan [3 ,4 ]
Sagl, Benedikt [5 ]
Jonke, Erwin [1 ]
机构
[1] Med Univ Vienna, Univ Clin Dent, Dept Orthodont, Vienna, Austria
[2] Saarland Univ, Dept Orthodont, Saar, Germany
[3] Med Univ Vienna, Univ Clin Dent, Karl Donath Lab Hard Tissue & Biomat Res, Vienna, Austria
[4] Austrian Cluster Tissue Regenerat, Vienna, Austria
[5] Med Univ Vienna, Univ Clin Dent, Ctr Clin Res, Vienna, Austria
关键词
Digital dentistry; Temporary anchorage devices; Guided implantation; CAD/CAM; Dental milling; Medical 3D printing; SKELETAL; INSERTION;
D O I
10.1016/j.jdent.2024.105060
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Temporary anchorage devices (TADs) have become an integral part of comprehensive orthodontic treatments. This study evaluated the transfer accuracy of three-dimensional (3D) printed and computer-aided design/computer-aided manufacturing (CAD/CAM) milled surgical guides for orthodontic TADs using micro- computed tomography (CT) imaging in a preclinical trial. Methods: Overall, 30 surgical guides were used to place TADs into typodonts; 3D printing and CAD/CAM milling were used to produce the guides. The virtual target positions of the TADs were compared to the real positions in terms of spatial and angular deviations using digital superimposition. Micro-CT imaging was used to detect the positions. To evaluate reliability, two investigators collected the measurements twice. Intra-rater and inter-rater correlations were tested. Results: In total, 60 palatal TADs were evaluated. The mean coronal deviations in the print group ranged from 0.15 f 0.20 mm to 0.71 f 0.22 mm, whereas in the mill group, they ranged from 0.09 f 0.15 mm to 0.83 f 0.23 mm. At the apical tip, the overall deviations in the print group ranged from 0.14 f 0.56 mm to 1.27 f 0.66 mm, whereas in the mill group, they ranged from 0.15 f 0.57 mm to 1.09 f 0.44 mm. The mean intra-class and interclass correlation coefficients ranged from 0.904 to 0.987. No statistically significant differences were found between the groups. Conclusions: CAD/CAM milled guides yielded spatial and angular accuracies comparable to those of 3D printed guides with notable deviations in the vertical positioning of TADs. Clinical significance: Digital planning of orthodontic temporary implants combines clinical predictability and the safety of surrounding tissue. Therefore, the transfer accuracy of the guides is crucial. This preclinical study was the first to evaluate CAD/CAM milling for orthodontic guides and found its accuracy comparable to that of the current "gold standard".
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Investigating the accuracy of mandibulectomy and reconstructive surgery using 3D customized implants and surgical guides in a rabbit model
    Kim, Min Keun
    Ham, Min Ji
    Kim, Won Rae
    Kim, Hyung Giun
    Kwon, Kwang Jun
    Kim, Seong Gon
    Park, Young Wook
    MAXILLOFACIAL PLASTIC AND RECONSTRUCTIVE SURGERY, 2023, 45 (01)
  • [22] Effect of aging on dimensional accuracy and color stability of CAD-CAM milled and 3D-printed denture base resins: a comparative in-vitro study
    Gad, Marwa A.
    Abdelhamid, Ahmed M.
    ElSamahy, Mahmoud
    Abolgheit, Salma
    Hanno, Kenda I.
    BMC ORAL HEALTH, 2024, 24 (01):
  • [23] Maxillary Total Elongation Surgery using 3D Virtual Surgery, CAD/CAM and 3D Printing Technology: Surgical Convenience and Accuracy
    Ha, Sung-Ho
    Maeng, Ji Youn
    Baek, Seung-Hak
    Choi, Jin-Young
    JOURNAL OF CRANIOFACIAL SURGERY, 2022, 33 (07) : 2172 - 2177
  • [24] ACL tunnel placement using 3D printed surgical guides – a porcine feasibility study
    Sophie C. Eberlein
    Silvan Hess
    Samuel F Schaible
    Frank M. Klenke
    Andreas Hecker
    3D Printing in Medicine, 11 (1)
  • [25] Analysis of the residual monomer content in milled and 3D-printed removable CAD-CAM complete dentures: an in vitro study
    Srinivasan, Murali
    Chien, Edward Chaoho
    Kalberer, Nicole
    Alambiaga Caravaca, Adrian Miguel
    Lopez-Castellano, Alicia
    Kamnoedboon, Porawit
    Sauro, Salvatore
    Ozcan, Mutlu
    Mueller, Frauke
    Wismeijer, Daniel
    JOURNAL OF DENTISTRY, 2022, 120
  • [26] The effect of cyclic loading on the fracture resistance of 3D-printed and CAD/CAM milled zirconia crowns-an in vitro study
    Refaie, Ashraf
    Bourauel, Christoph
    Fouda, Ahmed Mahmoud
    Keilig, Ludger
    Singer, Lamia
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (10) : 6125 - 6133
  • [27] Accuracy and precision of 3D-printed implant surgical guides with different implant systems: An in vitro study
    Yeung, Matthew
    Abdulmajeed, Aous
    Carrico, Caroline K.
    Deeb, George R.
    Bencharit, Sompop
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (06): : 821 - 828
  • [28] In-vitro Comparative Evaluation for the Surface Properties and Impact Strength of CAD/CAM Milled, 3D Printed, and Polyamide Denture Base Resins
    Helal, Mohamed A.
    Fadl-Alah, Ahmed
    Baraka, Yasser M.
    Gad, Mohammed M.
    Emam, Abdel-Naser M.
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2022, 12 (01): : 126 - 131
  • [29] Investigation of the effects of spinal surgical implants on radiotherapy dosimetry: A study of 3D printed phantoms
    Goodall, Simon K.
    Rampant, Peter
    Smith, Warwick
    Waterhouse, David
    Rowshanfarzad, Pejman
    Ebert, Martin A.
    MEDICAL PHYSICS, 2021, 48 (08) : 4586 - 4597
  • [30] 3D printed fracture reduction guides planned and printed at the point of care show high accuracy - A cadaveric feasibility study
    Eberlein, Sophie C.
    Hess, Silvan
    Klenke, Frank Michael
    Hecker, Andreas
    SWISS MEDICAL WEEKLY, 2023, 153 : 54S - 54S