Accuracy of palatal orthodontic mini-implants placed by conventionally or CAD/CAM-based surgical guides: a comparative in vitro study

被引:3
|
作者
de la Rosa, Maria R. Mang [1 ,2 ,3 ]
Safaltin, Ayse
Jost-Brinkmann, Paul -Georg [1 ,2 ,3 ]
Aigner, Annette [4 ]
Koch, Petra Julia [1 ,2 ,3 ,5 ]
机构
[1] Charite Univ Med Berlin, Dept Orthodont, Dentofacial Orthoped, Ctr Oral Hlth Sci, Berlin, Germany
[2] Free Univ Berlin, Berlin, Germany
[3] Humboldt Univ, Berlin, Germany
[4] Charite Univ Med Berlin, Inst Biometry & Clin Epidemiol, Berlin, Germany
[5] Dept Orthodont & Dentofacial Orthoped, Assmannshauser Str 4-6, D-14197 Berlin, Germany
关键词
Orthodontic mini-implant (OMI); Surgical guide (SG); Transfer accuracy; Digital orthodontics; APPLIANCE;
D O I
10.2319/011722-55.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To investigate and compare the transfer accuracy of five different surgical guides (SGs) for the insertion of orthodontic mini-implants (OMIs) in the anterior palate.Materials and Methods: Stereolithographic files of 10 maxillary patient models and their corresponding lateral cephalograms were virtually matched and used for planning the position of two parallel OMIs in the paramedian region of the anterior palate. For each patient model, three 3 -dimensional (3D)-printed and two conventional SGs were manufactured from different materials, and a total of 96 OMIs were transferred to the anterior palates of the respective 50 molded resin models. The planned (T0) and the actual (T1) OMI positions were analyzed and compared after superimposition of the digitized models. The deviations between the OMI positions in T0 and T1 were described as the distance between the head and the tip, respectively, of each OMI in millimeters and the deviating angle between the OMI axes for each patient and SG.Results: The conventionally manufactured SGs of Pattern Resin LS (GC Europe N.V., Leuven, Belgium) showed the highest linear and angular transfer accuracy for the insertion of OMIs. The highest deviations were found with the SGs made of IMPRIMO LC Splint (3D-printed; Scheu-Dental, Iserlohn, Germany) and Memosil 2 (conventional SG; Kulzer, Hanau, Germany).Conclusions: The 3D-printed SGs did not reach the accuracy of the conventional SGs made of Pattern Resin but may provide sufficient accuracy for palatal OMI placement. (Angle Orthod. 2022;93:79-87.)
引用
收藏
页码:79 / 87
页数:9
相关论文
共 49 条
  • [1] Accuracy of Palatal Orthodontic Mini-Implants Placed Using Fully Digital Planned Insertion Guides: A Cadaver Study
    Stursa, Lea
    Wendl, Brigitte
    Jakse, Norbert
    Pichelmayer, Margit
    Weiland, Frank
    Antipova, Veronica
    Kirnbauer, Barbara
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (21)
  • [2] Accuracy of Sterile and Non-Sterile CAD/CAM Insertion Guides for Orthodontic Mini-Implants
    Ludwig, Bjoern
    Krause, Luisa
    Venugopal, Adith
    FRONTIERS IN DENTAL MEDICINE, 2022, 3
  • [3] Pullout strengths of orthodontic palatal mini-implants tested in vitro
    Wu, Ju-Hui
    Wang, Huang-Chi
    Chen, Chun-Ming
    Lu, Pei-Chen
    Lai, Sheng-Tsung
    Lee, Kun-Tsung
    Du, Je-Kang
    JOURNAL OF DENTAL SCIENCES, 2011, 6 (04) : 200 - 204
  • [4] The success rate of infrazygomatic mini-implants placed with and without surgical guides: a historical control study
    Lixian Yuan
    Ruifeng Zhao
    Jingjing Liu
    Rui Tang
    Shizhu Bai
    Xin Liu
    BMC Oral Health, 25 (1)
  • [5] Fracture resistance of orthodontic mini-implants: a biomechanical in vitro study
    Wilmes, Benedict
    Panayotidis, Agamemnon
    Drescher, Dieter
    EUROPEAN JOURNAL OF ORTHODONTICS, 2011, 33 (04) : 396 - 401
  • [6] An in vitro study of factors affecting the primary stability of orthodontic mini-implants
    Holm, Lindsy
    Cunningham, Susan J.
    Petrie, Aviva
    Cousley, Richard R. J.
    ANGLE ORTHODONTIST, 2012, 82 (06) : 1022 - 1028
  • [7] In vitro study of human osteoblast proliferation and morphology on orthodontic mini-implants
    Bueno, Ricardo Carvalho
    Basting, Roberta Tarkany
    ANGLE ORTHODONTIST, 2015, 85 (06) : 920 - 926
  • [8] In vitro study of the orthodontic mini-implants influence on the growth of human osteoblasts
    Moldoveanu, Andreea
    Nicolescu, Mihnea Ioan
    Bucur, Mirela Veronica
    Moldoveanu, George-Gabriel
    Funieru, Cristian
    Neagoe, Ionela-Victoria
    Manda, Gina
    Ioana, Tamara-Rahela
    Ciocan, Lucian Toma
    ROMANIAN JOURNAL OF MORPHOLOGY AND EMBRYOLOGY, 2021, 62 (03): : 785 - 792
  • [9] Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study
    She, Ha-Na
    Choi, Sung-Hwan
    Yu, Hyung-Seog
    Hwang, Chung-Ju
    Cha, Jung-Yul
    Kim, Kwang-Mahn
    PLOS ONE, 2018, 13 (09):
  • [10] Comparison of the accuracy of implants placed with CAD-CAM surgical templates manufactured with various 3D printers: An in vitro study
    Herschdorfer, Laura
    Negreiros, William Matthew
    Gallucci, German O.
    Hamilton, Adam
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (06): : 905 - 910