Accuracy of palatal orthodontic mini-implants placed by conventionally or CAD/CAM-based surgical guides: a comparative in vitro study

被引:3
|
作者
de la Rosa, Maria R. Mang [1 ,2 ,3 ]
Safaltin, Ayse
Jost-Brinkmann, Paul -Georg [1 ,2 ,3 ]
Aigner, Annette [4 ]
Koch, Petra Julia [1 ,2 ,3 ,5 ]
机构
[1] Charite Univ Med Berlin, Dept Orthodont, Dentofacial Orthoped, Ctr Oral Hlth Sci, Berlin, Germany
[2] Free Univ Berlin, Berlin, Germany
[3] Humboldt Univ, Berlin, Germany
[4] Charite Univ Med Berlin, Inst Biometry & Clin Epidemiol, Berlin, Germany
[5] Dept Orthodont & Dentofacial Orthoped, Assmannshauser Str 4-6, D-14197 Berlin, Germany
关键词
Orthodontic mini-implant (OMI); Surgical guide (SG); Transfer accuracy; Digital orthodontics; APPLIANCE;
D O I
10.2319/011722-55.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To investigate and compare the transfer accuracy of five different surgical guides (SGs) for the insertion of orthodontic mini-implants (OMIs) in the anterior palate.Materials and Methods: Stereolithographic files of 10 maxillary patient models and their corresponding lateral cephalograms were virtually matched and used for planning the position of two parallel OMIs in the paramedian region of the anterior palate. For each patient model, three 3 -dimensional (3D)-printed and two conventional SGs were manufactured from different materials, and a total of 96 OMIs were transferred to the anterior palates of the respective 50 molded resin models. The planned (T0) and the actual (T1) OMI positions were analyzed and compared after superimposition of the digitized models. The deviations between the OMI positions in T0 and T1 were described as the distance between the head and the tip, respectively, of each OMI in millimeters and the deviating angle between the OMI axes for each patient and SG.Results: The conventionally manufactured SGs of Pattern Resin LS (GC Europe N.V., Leuven, Belgium) showed the highest linear and angular transfer accuracy for the insertion of OMIs. The highest deviations were found with the SGs made of IMPRIMO LC Splint (3D-printed; Scheu-Dental, Iserlohn, Germany) and Memosil 2 (conventional SG; Kulzer, Hanau, Germany).Conclusions: The 3D-printed SGs did not reach the accuracy of the conventional SGs made of Pattern Resin but may provide sufficient accuracy for palatal OMI placement. (Angle Orthod. 2022;93:79-87.)
引用
收藏
页码:79 / 87
页数:9
相关论文
共 49 条
  • [41] Effect of the computer-aided static navigation technique on the accuracy of bicortical mini-implants placement site for maxillary skeletal expansion appliances: an in vitro study
    Paulina Rodríguez Torres
    Elena Riad Deglow
    Álvaro Zubizarreta-Macho
    Georgia Tzironi
    Héctor González Menéndez
    Juan Lorrio Castro
    Ana Belén Lobo Galindo
    Sofía Hernández Montero
    BMC Oral Health, 23
  • [42] Comparison of the strain developed around implants with angled abutments with two reinforced polymeric CAD-CAM superstructure materials: An in vitro comparative study
    Omaish, Hadeer Hassan M.
    Abdelhamid, Ahmed M.
    Neena, Akram F.
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (04): : 634.e1 - 634.e8
  • [43] Accuracy of intraoral real-time navigation versus static, CAD/CAM-manufactured pilot drilling guides in dental implant surgery: an in vitro study
    Robert Stünkel
    Alexander-Nicolai Zeller
    Thomas Bohne
    Florian Böhrnsen
    Edris Wedi
    David Raschke
    Philipp Kauffmann
    International Journal of Implant Dentistry, 8
  • [44] Accuracy of intraoral real-time navigation versus static, CAD/CAM-manufactured pilot drilling guides in dental implant surgery: an in vitro study
    Stuenkel, Robert
    Zeller, Alexander-Nicolai
    Bohne, Thomas
    Boehrnsen, Florian
    Wedi, Edris
    Raschke, David
    Kauffmann, Philipp
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2022, 8 (01)
  • [45] Comparison of the accuracy of impressions made of 2 implants with interfering axial convergence with CAD-CAM impression copings and the altered cast technique: An in vitro study
    Sadegholvad, Maryam
    Ansarifard, Elham
    Derafshi, Reza
    Dehno, Seyede Mina Salehi
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04): : 745.e1 - 745.e7
  • [46] Evaluation of surgical placement accuracy of customized CAD/CAM titanium mesh using screws-position-guided template: A retrospective comparative study
    Chen, Dan
    Zheng, Lingling
    Wang, Chao
    Huang, Yuanding
    Huang, Haitao
    Apicella, Antonio
    Hu, Guiping
    Wang, Lizhen
    Fan, Yubo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2023, 25 (03) : 519 - 531
  • [47] Accuracy assessment of implant placement with versus without a CAD/CAM surgical guide by novices versus specialists via the digital registration method: an in vitro randomized crossover study
    Li, Sha
    Yi, Chun
    Yu, Ziyang
    Wu, Aozhou
    Zhang, Yu
    Lin, Ye
    BMC ORAL HEALTH, 2023, 23 (01)
  • [48] Accuracy assessment of implant placement with versus without a CAD/CAM surgical guide by novices versus specialists via the digital registration method: an in vitro randomized crossover study
    Sha Li
    Chun Yi
    Ziyang Yu
    Aozhou Wu
    Yu Zhang
    Ye Lin
    BMC Oral Health, 23
  • [49] Effect of aging on dimensional accuracy and color stability of CAD-CAM milled and 3D-printed denture base resins: a comparative in-vitro study
    Gad, Marwa A.
    Abdelhamid, Ahmed M.
    ElSamahy, Mahmoud
    Abolgheit, Salma
    Hanno, Kenda I.
    BMC ORAL HEALTH, 2024, 24 (01):