Fracture Resistance of Posterior Milled Nanoceramic Crowns after Thermomechanical Aging

被引:0
|
作者
Alnajjar, Fajer Abdulaziz [1 ]
Alloughani, Arwa Jamal [1 ]
Alhajj, Mohammed Nasser [2 ]
Baig, Mirza Rustum [3 ]
机构
[1] Kuwait Univ, Coll Dent, POB 24923, Kuwait, Kuwait
[2] Thamar Univ, Fac Dent, Dept Prosthodont, POB 13020, Dhamar, Yemen
[3] Kuwait Univ, Coll Dent, Dept Restorat Sci Prosthodont, POB 24923, Kuwait, Kuwait
关键词
lithium disilicate; nanoceramic; fracture load; CAD/CAM; dynamic loading;
D O I
10.3390/jfb15070171
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fracture resistance is an important parameter used to predict the performance of indirect dental restorations. The purpose of this in vitro study was to assess the fracture load of posterior milled nanoceramic crowns, in comparison with the lithium disilicate crowns, after fatigue loading, for two different restoration occlusal thicknesses. Forty test metal dies were fabricated by duplicating a master metal model consisting of an anatomic abutment preparation of the maxillary first premolar for a single crown. The dies were divided into two groups of 20 each for the fabrication of nanoceramic (Lava Ultimate) and lithium disilicate (IPS e.max CAD) single crowns. Each material group was further divided into two sub-groups of 10 dies each, based on crown occlusal thickness, of 0.5-mm and 0.75-mm (n = 10). Dental Type V stone dies poured from polyvinyl siloxane impressions of the test metal dies were laboratory scanned in order to design and mill 40 ceramic crowns. The crowns were cemented on to the test metal dies with a self-adhesive resin luting cement. All crowns were thermocycled (2500 cycles) and mechanically loaded (250,000 cycles) in a chewing simulator followed by static loading until failure, and the values noted. The data were statistically analyzed by 2-way ANOVA and Tukey HSD post-hoc multiple comparison tests (alpha = 0.05). The mean fracture loads ranged from 1022 to 1322 N for nanoceramic crowns and from 1145 to 1441 N for the lithium disilicate crowns. Two-way ANOVA revealed insignificant differences between the nanoceramic and lithium disilicate crowns (p > 0.05) in terms of fracture load. Significant differences were noted in the fracture resistance of crowns based on occlusal thickness (303 N; p = 0.013) regardless of the material used. Multiple comparisons by Tukey HSD post-hoc test showed insignificant differences between the four material-occlusal thickness groups (p > 0.05). The nanoceramic crowns were found to be comparable with lithium disilicate crowns in terms of fracture load. The mean fracture loads of all of the tested crowns were within the normal physiological masticatory load limits. Based on the fracture-resistance results, nanoceramic crowns seem to be suitable for clinical use for the tested occlusal thicknesses.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] The influence of aging on the fracture load of milled monolithic crowns
    Ceyda Güleç
    Işıl Sarıkaya
    BMC Oral Health, 22
  • [2] The influence of aging on the fracture load of milled monolithic crowns
    Gulec, Ceyda
    Sarikaya, Isil
    BMC ORAL HEALTH, 2022, 22 (01)
  • [3] Influence of Thermomechanical Fatigue Loading on the Fracture Resistance of All-ceramic Posterior Crowns
    Senyilmaz, Dilek Pinar
    Canay, Senay
    Heydecke, Guido
    Strub, Joerg Rudolf
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2010, 18 (02): : 50 - 54
  • [4] Fracture resistance of posterior metal free polymer crowns
    Eickemeyer, G
    Rammelsberg, P
    Erdelt, K
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 444 - 444
  • [5] Thermomechanical aging effects on vertical marginal gap and fracture resistance: a comparative study of Bioflx and traditional pediatric crowns
    Abo-Elsoud, Asmaa Ali Emam
    Mohamady, Eman Mohamed
    Fathi Abdou, Noha El-Sayed
    BMC ORAL HEALTH, 2024, 24 (01):
  • [6] Fracture resistance of additive manufactured and milled implant-supported interim crowns
    Martin-Ortega, Nuria
    Sallorenzo, Alessandro
    Casajus, Javier
    Cervera, Alberto
    Revilla-Leon, Marta
    Gomez-Polo, Miguel
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (02): : 267 - 274
  • [7] Digital versus conventional veneering of zirconia and cobalt chromium crowns: Fracture load before and after thermomechanical aging
    Mayinger, Felicitas
    Meinen, John
    Coldea, Andrea
    Zimmermann, Marcus
    Stawarczyk, Bogna
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (02): : 251e1 - 251e8
  • [8] Fracture strength of endocrowns after thermomechanical aging
    Dikici, Burcu
    Can, Esra
    Basaran, Elif Turkes
    Barut, Guher
    Donmez, Nazmiye
    ODONTOLOGY, 2024, 112 (03) : 884 - 894
  • [9] Fracture resistance of posterior metal-free polymer crowns
    Rammelsberg, P
    Eickemeyer, G
    Erdelt, K
    Pospiech, P
    JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (03): : 303 - 308
  • [10] Fracture resistance of cement-retained and screw-cement-retained milled posterior crowns with screw-access hole preparations before and after firing: An in vitro study
    Cabrera, Jesus Enrique
    Belles, Donald M.
    Sauceda, Ruben A.
    Arriaga, Dianna M.
    Ontiveros, Joe C.
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (05): : 768 - 774