Fracture Resistance of Posterior Milled Nanoceramic Crowns after Thermomechanical Aging

被引:0
|
作者
Alnajjar, Fajer Abdulaziz [1 ]
Alloughani, Arwa Jamal [1 ]
Alhajj, Mohammed Nasser [2 ]
Baig, Mirza Rustum [3 ]
机构
[1] Kuwait Univ, Coll Dent, POB 24923, Kuwait, Kuwait
[2] Thamar Univ, Fac Dent, Dept Prosthodont, POB 13020, Dhamar, Yemen
[3] Kuwait Univ, Coll Dent, Dept Restorat Sci Prosthodont, POB 24923, Kuwait, Kuwait
关键词
lithium disilicate; nanoceramic; fracture load; CAD/CAM; dynamic loading;
D O I
10.3390/jfb15070171
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fracture resistance is an important parameter used to predict the performance of indirect dental restorations. The purpose of this in vitro study was to assess the fracture load of posterior milled nanoceramic crowns, in comparison with the lithium disilicate crowns, after fatigue loading, for two different restoration occlusal thicknesses. Forty test metal dies were fabricated by duplicating a master metal model consisting of an anatomic abutment preparation of the maxillary first premolar for a single crown. The dies were divided into two groups of 20 each for the fabrication of nanoceramic (Lava Ultimate) and lithium disilicate (IPS e.max CAD) single crowns. Each material group was further divided into two sub-groups of 10 dies each, based on crown occlusal thickness, of 0.5-mm and 0.75-mm (n = 10). Dental Type V stone dies poured from polyvinyl siloxane impressions of the test metal dies were laboratory scanned in order to design and mill 40 ceramic crowns. The crowns were cemented on to the test metal dies with a self-adhesive resin luting cement. All crowns were thermocycled (2500 cycles) and mechanically loaded (250,000 cycles) in a chewing simulator followed by static loading until failure, and the values noted. The data were statistically analyzed by 2-way ANOVA and Tukey HSD post-hoc multiple comparison tests (alpha = 0.05). The mean fracture loads ranged from 1022 to 1322 N for nanoceramic crowns and from 1145 to 1441 N for the lithium disilicate crowns. Two-way ANOVA revealed insignificant differences between the nanoceramic and lithium disilicate crowns (p > 0.05) in terms of fracture load. Significant differences were noted in the fracture resistance of crowns based on occlusal thickness (303 N; p = 0.013) regardless of the material used. Multiple comparisons by Tukey HSD post-hoc test showed insignificant differences between the four material-occlusal thickness groups (p > 0.05). The nanoceramic crowns were found to be comparable with lithium disilicate crowns in terms of fracture load. The mean fracture loads of all of the tested crowns were within the normal physiological masticatory load limits. Based on the fracture-resistance results, nanoceramic crowns seem to be suitable for clinical use for the tested occlusal thicknesses.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Evaluation of Dimensional Stability and Occlusal Wear of Additively and Subtractively Manufactured Resin-Based Crowns after Thermomechanical Aging
    Guven, Mehmet Esad
    Cakmak, Gulce
    Donmez, Mustafa Borga
    Yilmaz, Burak
    APPLIED SCIENCES-BASEL, 2023, 13 (21):
  • [42] Marginal adaptation and fracture resistance of 3D-printed and CAD/CAM-milled definitive resin matrix ceramic crowns
    Abdulkareem, Maryam A.
    Al-Shamma, Abdulla M. W.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2024, 27 (04)
  • [43] The effect of cyclic loading on the fracture resistance of 3D-printed and CAD/CAM milled zirconia crowns-an in vitro study
    Refaie, Ashraf
    Bourauel, Christoph
    Fouda, Ahmed Mahmoud
    Keilig, Ludger
    Singer, Lamia
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (10) : 6125 - 6133
  • [44] Fracture Resistance of Primary Zirconia Crowns: An In Vitro Study
    Abushanan, AlWaleed
    Sharanesha, Rajashekhara B.
    Aljuaid, Bader
    Alfaifi, Tariq
    Aldurayhim, Abdullah
    CHILDREN-BASEL, 2022, 9 (01):
  • [45] Aging and Fracture Resistance of Implant-Supported Molar Crowns with a CAD/CAM Resin Composite Veneer Structure
    Rauch, Angelika
    Heinzmann, Wendy
    Rosentritt, Martin
    Hahnel, Sebastian
    Schmidt, Michael Benno
    Fuchs, Florian
    Koenig, Andreas
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (18)
  • [46] Comparative evaluation of the fracture resistance of newly developed prefabricated fibreglass crowns and zirconium crowns
    Ciftci, Zulfikar Zahit
    Sahin, Ipek
    Karayilmaz, Huseyin
    INTERNATIONAL JOURNAL OF PAEDIATRIC DENTISTRY, 2022, 32 (05) : 756 - 763
  • [47] FRACTURE-RESISTANCE OF HIGH-STRENGTH STEEL STRIP AFTER THERMOMECHANICAL TREATMENT
    GROSVALD, VG
    ENTIN, RI
    GOLTSEV, VY
    DROZDOVS.BA
    NIKITIN, VA
    KOROLEV, AA
    PANASYUK, VF
    BASHCHEN.AP
    RUSSIAN METALLURGY, 1973, (01): : 108 - 110
  • [48] Fracture resistance of zirconia-based all-ceramic crowns after bur adjustment
    Rues, Stefan
    Schwindling, Franz S.
    Meyer, Andre
    Rammelsberg, Peter
    Schmitter, Marc
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2017, 125 (04) : 310 - 313
  • [49] Marginal fit and fracture resistance of polyetheretherketone, zirconia, and titanium implant-supported prosthesis frameworks for a partially edentulous arch after thermomechanical aging
    Atsu, Saadet
    Erol, Ulas
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (02): : 273 - 280
  • [50] Fracture Resistance of Repaired 5Y-PSZ Zirconia Crowns after Endodontic Access
    Greuling, Andreas
    Wiemken, Mira
    Kahra, Christoph
    Maier, Hans Juergen
    Eisenburger, Michael
    DENTISTRY JOURNAL, 2023, 11 (03)