Fracture resistance of posterior metal-free polymer crowns

被引:50
|
作者
Rammelsberg, P [1 ]
Eickemeyer, G [1 ]
Erdelt, K [1 ]
Pospiech, P [1 ]
机构
[1] Univ Munich, Poliklin Zahnarztliche Prothet, Dept Prosthet Dent, D-80336 Munich, Germany
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2000年 / 84卷 / 03期
关键词
D O I
10.1067/mpr.2000.108068
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Improved mechanical properties of contemporary composites has resulted in the extended use of composites for the restoration of posterior teeth. Although the indication of polymers was extended to metal-free individual crowns, the influence of tooth preparation design and cementation methods on the stability of these artificial crowns remains unknown. Purpose. This in vitro study evaluated the effect of axial tooth preparation design, occlusal dimension, and cementation technique on the fracture resistance of metal-free posterior Artglass crowns. Material and methods. Seventy-two extracted human third molars, assigned to experimental groups by size, received standardized tooth preparation. Axial tooth preparation included an invasive approach with l-mm deep shoulder and a less invasive 0.5-mm chamfer preparation, whereas occlusal reduction was either 0.5 mm or 1.3 mm. Artglass crowns that restored the original tooth contour were cemented with 3 cements: title phosphate cement (ZnP), glass ionomer cement (GIC), or a resinous cement in combination with a dentinal bonding agent. After 10,000 thermal cycles between 5 degrees C and 55 degrees C, artificial crowns were vertically loaded until compression to failure. Significant differences of fracture loads between experimental groups were assessed by paired Mann-Whitney U tests. Results. Minimal fracture resistance for all combinations excluded 500 N. However, 9 of 24 Artglass crowns cemented with ZnP loosened after thermocycling. Adhesive cementation resulted in a significantly greater fracture resistance compared with GIC and ZnP (P=.02). increased occlusal thickness (0.5 to 1.3 mm) resulted in greater stability, whereas a l-mm deep shoulder tooth preparation did not improve durability compared with a 0.5-mm chamfer finishing line. Conclusion. A minimally invasive 0.5-mm axial chamfer tooth preparation combined with sufficient occlusal reduction and adhesive cementation recorded thr greatest stability for posterior metal-free Artglass crowns.
引用
收藏
页码:303 / 308
页数:6
相关论文
共 50 条
  • [1] Fracture resistance of posterior metal free polymer crowns
    Eickemeyer, G
    Rammelsberg, P
    Erdelt, K
    [J]. JOURNAL OF DENTAL RESEARCH, 2000, 79 : 444 - 444
  • [2] Wear of posterior metal-free polymer crowns after 2 years
    Ohlmann, B.
    Trame, J. -P.
    Dreyhaupt, J.
    Gabbert, O.
    Koob, A.
    Rammelsberg, P.
    [J]. JOURNAL OF ORAL REHABILITATION, 2008, 35 (10) : 782 - 788
  • [4] Influence of abutment substrates on the colour of metal-free polymer crowns
    Nakamura, T
    Saito, O
    Mizuno, M
    Kinuta, S
    Ishigaki, S
    [J]. JOURNAL OF ORAL REHABILITATION, 2003, 30 (02) : 184 - 188
  • [5] Comparison of incidence of complications and aesthetic performance for posterior metal-free polymer crowns and metal-ceramic crowns: Results from a randomized clinical trial
    Ohlmann, Brigitte
    Bermejo, Justo Lorenzo
    Rammelsberg, Peter
    Schmitter, Marc
    Zenthoefer, Andreas
    Stober, Thomas
    [J]. JOURNAL OF DENTISTRY, 2014, 42 (06) : 671 - 676
  • [6] Fracture resistance of metal-free composite crowns - Effects of fiber reinforcement, thermal cycling, and cementation technique
    Lehmann, F
    Eickemeyer, G
    Rammelsberg, P
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (03): : 258 - 264
  • [7] Fracture resistance and the mode of failure produced in metal-free crowns cemented onto zirconia abutments in dental implants
    Agustin-Panadero, Ruben
    Serra-Pastor, Blanca
    Roig-Vanaclocha, Ana
    Fons-Font, Antonio
    Fernanda Sola-Ruiz, Maria
    [J]. PLOS ONE, 2019, 14 (08):
  • [8] Clinical wear of posterior metal-free polymer crowns one-year results from a randomized clinical trial
    Ohlmann, Brigitte
    Uekermann, Jan
    Dreyhaupt, Jens
    Schmitter, Marc
    Mussotter, Katrin
    Rammelsberg, Peter
    [J]. JOURNAL OF DENTISTRY, 2007, 35 (03) : 246 - 252
  • [9] Clinical performance of metal-free polymer crowns after 3 years in service
    Rammelsberg, P
    Spiegl, K
    Eickemeyer, G
    Schmitter, M
    [J]. JOURNAL OF DENTISTRY, 2005, 33 (06) : 517 - 523
  • [10] Occlusal stability and wear behavior of metal-free single polymer crowns.
    Hierlmeier, U.
    Gschossmann, K.
    Eickemeyer, G.
    Rammelsberg, P.
    [J]. JOURNAL OF DENTAL RESEARCH, 2003, 82 : B340 - B340