Redundant Induced Bracing Failures in Transmission Line Towers

被引:0
|
作者
Rao, N. Prasad [1 ]
Balagopal, R. [1 ]
Rokade, R. P. [1 ]
Palani, G. S. [1 ]
机构
[1] CSIR Struct Engn Res Ctr, CSIR Rd, Chennai 600113, Tamil Nadu, India
关键词
Transmission line tower; Redundant; Primary bracing; Failure; Connection detail; Tower testing; BEHAVIOR;
D O I
10.1007/s13296-024-00897-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Transmission line towers designed based on the provisions of different standards may fail during mandatory testing for many reasons. Two different types of premature failures observed during full-scale testing at Tower Testing and Research Station, Structural Engineering Research Centre, Chennai (CSIR-SERC), are studied in this paper. These towers failed prematurely due to improper design assumptions secondary to the primary bracing connection. The failures are modelled using general-purpose finite element software. The test and analytical results are compared with various codal provisions. Hip bracing connected to primary bracing with a single bolt acts as a hinge and fails to provide adequate restraint. The assumption that hip bracing provides restraint to the primary bracing against the in-plane deformation is invalid, and it can only prevent the primary member's displacement along the hip's axis due to its axial stiffness. This study recommends a double bolt connection for redundant members.
引用
收藏
页码:1154 / 1164
页数:11
相关论文
共 50 条
  • [21] An intelligent design system for overhead transmission line towers
    Santana, S
    Pineda, LA
    Vadera, S
    4TH WORLD CONGRESS OF EXPERT SYSTEMS, VOL 1 AND 2: APPLICATION OF ADVANCED INFORMATION TECHNOLOGIES, 1998, : 270 - 277
  • [22] Reliability-based optimization of transmission line towers
    Anna Univ, Madras, India
    Comput Struct, 3 (387-403):
  • [23] Insulation design of 400 KV transmission line towers
    Chanana, Anil
    Irrigation and Power, 1988, 45 (04): : 25 - 35
  • [24] IMPULSE CHARACTERISTICS OF EARTHINGS FOR TRANSMISSION-LINE TOWERS
    RYABKOVA, EY
    MISHKIN, VM
    ELECTRICAL TECHNOLOGY, 1976, (03): : 62 - 70
  • [25] Thor – a New Design of Overhead Transmission Line Towers
    Schmidt, Mark Kokborg
    Nielsen, Mogens G.
    Endahl, Brian
    Steenholt-Eliasson, Karl Emil
    ce/papers, 2019, 3 (3-4): : 403 - 408
  • [26] OPTIMUM ARRANGEMENT OF TOWERS IN AN ELECTRIC POWER TRANSMISSION LINE
    RANYARD, JC
    WREN, A
    COMPUTER JOURNAL, 1967, 10 (02): : 157 - &
  • [27] LIFTING OF TRANSMISSION TOWERS UNDER LIVE LINE CONDITIONS
    SKELTON, HE
    ORDE, CI
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (09): : 3018 - 3021
  • [28] OPTIMUM CONFIGURATION STUDY OF TRANSMISSION LINE TOWERS.
    Kapoor, M.P.
    Kumaraswamy, K.
    Irrigation and Power, 1980, 37 (03): : 359 - 369
  • [29] Transmission line failures during tornadoes and downbursts
    El Damatty, Ashraf
    Elawady, Amal
    Hamada, Mohamed
    INSIGHTS AND INNOVATIONS IN STRUCTURAL ENGINEERING, MECHANICS AND COMPUTATION, 2016, : 2022 - 2027
  • [30] Behavior of cross-bracing in latticed towers
    Kemp, AR
    Behncke, RH
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1998, 124 (04): : 360 - 367