Fill, Fold, Photo: Preconcentration and Multiplex Detection of Trace Level Heavy Metals in Water

被引:4
|
作者
Aryal, Prakash [1 ]
Boes, Jason [1 ]
Brack, Eric [2 ]
Alexander, Todd [2 ]
Henry, Charles S. [1 ,3 ,4 ,5 ]
机构
[1] Colorado State Univ, Dept Chem, Ft Collins, CO 80523 USA
[2] US Army Combat Capabil Dev Command DEVCOM Soldier, Natick, MA 01760 USA
[3] Colorado State Univ, Dept Chem & Biol Engn, Ft Collins, CO 80523 USA
[4] Colorado State Univ, Sch Biomed Engn, Ft Collins, CO 80523 USA
[5] Chulalongkorn Univ, Met & Mat Sci Res Inst, Bangkok 10330, Thailand
来源
ACS SENSORS | 2024年 / 9卷 / 10期
关键词
heavy metals; preconcentration; multiplex; paper-based detection; colorimetry; water contamination; PAPER-BASED DEVICE; COLORIMETRIC DETERMINATION; LEAD; COPPER; QUANTIFICATION; IONS; MICROFLUIDICS; CADMIUM; MERCURY; REAGENT;
D O I
10.1021/acssensors.4c01708
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Heavy metal contamination is an increasing global threat to human and environmental health, particularly in resource-limited areas. Traditional platforms for heavy metal detection are labor intensive and expensive and require lab facilities. While paper-based colorimetric sensors offer a simpler approach, their sensitivity limitations prevent them from meeting legislative requirements for many metals. Existing preconcentration systems, on the other hand, can achieve lower detection limits but typically focus on analyzing only one metal, making comprehensive monitoring difficult. We address these limitations by introducing a low-cost preconcentration system coupled with colorimetric analysis for the simultaneous detection of seven metal ions at low ppb levels without the need for external equipment outside a smartphone. The system achieved detection limits of 15 ppb (Ni(II)), 7 ppb (Cu(II)), 2 ppb (Fe(III)), 20 ppb (Cr(VI)), 13 ppb (Pb(II)), 26 ppb (Hg(II)), and 15 ppb (Mn(II)) with six out of seven limits of detection values falling well below EPA regulatory guidelines for drinking water. The user-friendly Fill, Fold, Photo approach eliminates complex pretreatment steps. Smartphone-based detection offers portable quantification within seconds. Employing masking strategies ensured higher selectivity for each assay on the card, while our packaging protocols enable system stability for over 4 weeks of study, facilitating mass production and deployment within a realistic time frame. To validate the sensor's performance in real-world scenarios, the sensor was tested with environmental water samples. The sensor demonstrated good recovery, ranging from 77% to 94% compared to the standard ICP-MS method. Furthermore, spike recovery analysis confirmed the sensor's accuracy, with a relative standard deviation (RSD) of less than 15%. This technology holds significant promise for future development as a convenient, portable solution for field-based monitoring of a broad spectrum of water contaminants, including pesticides, PFAS, fertilizers, and beyond.
引用
收藏
页码:5479 / 5488
页数:10
相关论文
共 50 条
  • [31] A Review of Microfluidic Detection Strategies for Heavy Metals in Water
    Lace, Annija
    Cleary, John
    CHEMOSENSORS, 2021, 9 (04)
  • [32] Heavy metals detection in river water with cantilever nanobiosensor
    Rigo, Aline Andressa
    De Cezaro, Alana Marie
    Muenchen, Daniela Kunkel
    Martinazzo, Janine
    Manzoli, Alexandra
    Steffens, Juliana
    Steffens, Clarice
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2020, 55 (03) : 239 - 249
  • [33] Preconcentration and Determination of Traces of Heavy Metals with Polymer Chelating Sorbents in the Analysis of Natural and Waste Water
    N. N. Basargin
    E. R. Oskotskaya
    G. I. Karpushina
    V. G. Senchakov
    Yu. G. Rozovskii
    Journal of Analytical Chemistry, 2003, 58 (7) : 617 - 618
  • [34] Preconcentration of heavy metals on multiwalled carbon nanotubes in water samples prior to analysis using FAAS
    Algamdi, Mohammad Saad
    Alghamdi, Abdullah Saeed
    Alsohaimi, Ibrahim Hotan
    Allohybi, Faiz Dakhil
    Alqadami, Ayoub Abdullah
    DESALINATION AND WATER TREATMENT, 2017, 69 : 261 - 267
  • [35] Determination of toxic heavy metals in sea water by FAAS after preconcentration with a novel chelating resin
    Manivannan, D.
    Biju, V. M.
    WATER SCIENCE AND TECHNOLOGY, 2011, 64 (04) : 803 - 808
  • [36] A dataset of 112 ligands for the preconcentration of mercury, uranium, lanthanum and other pollutants and heavy metals in water
    Kallithrakas-Kontos, N.
    Boultadaki, P.
    Foteinis, S.
    DATA IN BRIEF, 2020, 29
  • [37] Stripping voltammetric detection of trace heavy metals using gold ultramicroelectrode arrays
    Gutierez-Capitan, Manuel
    Baldi, Antoni
    Jimenez-Jorquera, Cecilia
    Fernandez-Sanchez, Cesar
    Gomez, Raquel
    Garcia, Virginia
    2014 IEEE 9TH IBERO-AMERICAN CONGRESS ON SENSORS (IBERSENSOR), 2014,
  • [38] Detection of Trace Heavy Metals Ions by Arrays of Titania Nanotubes Annealed in Nitrogen
    Zhao Zhi-man
    Xiao Peng
    Cao Guo-zhong
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2009, 25 (05) : 606 - 609
  • [39] Detection of Trace Heavy Metals Ions by Arrays of Titania Nanotubes Annealed in Nitrogen
    ZHAO Zhi-man1
    2. Department of Material Science and Engineering
    3. Department of Physics
    ChemicalResearchinChineseUniversities, 2009, 25 (05) : 606 - 609
  • [40] COMPLEXATION AND FOAM SEPARATION OF TRACE AMOUNTS OF HEAVY-METALS FROM WATER
    CARLESON, TE
    MOUSSAVI, M
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 95 - IAEC