Fill, Fold, Photo: Preconcentration and Multiplex Detection of Trace Level Heavy Metals in Water

被引:4
|
作者
Aryal, Prakash [1 ]
Boes, Jason [1 ]
Brack, Eric [2 ]
Alexander, Todd [2 ]
Henry, Charles S. [1 ,3 ,4 ,5 ]
机构
[1] Colorado State Univ, Dept Chem, Ft Collins, CO 80523 USA
[2] US Army Combat Capabil Dev Command DEVCOM Soldier, Natick, MA 01760 USA
[3] Colorado State Univ, Dept Chem & Biol Engn, Ft Collins, CO 80523 USA
[4] Colorado State Univ, Sch Biomed Engn, Ft Collins, CO 80523 USA
[5] Chulalongkorn Univ, Met & Mat Sci Res Inst, Bangkok 10330, Thailand
来源
ACS SENSORS | 2024年 / 9卷 / 10期
关键词
heavy metals; preconcentration; multiplex; paper-based detection; colorimetry; water contamination; PAPER-BASED DEVICE; COLORIMETRIC DETERMINATION; LEAD; COPPER; QUANTIFICATION; IONS; MICROFLUIDICS; CADMIUM; MERCURY; REAGENT;
D O I
10.1021/acssensors.4c01708
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Heavy metal contamination is an increasing global threat to human and environmental health, particularly in resource-limited areas. Traditional platforms for heavy metal detection are labor intensive and expensive and require lab facilities. While paper-based colorimetric sensors offer a simpler approach, their sensitivity limitations prevent them from meeting legislative requirements for many metals. Existing preconcentration systems, on the other hand, can achieve lower detection limits but typically focus on analyzing only one metal, making comprehensive monitoring difficult. We address these limitations by introducing a low-cost preconcentration system coupled with colorimetric analysis for the simultaneous detection of seven metal ions at low ppb levels without the need for external equipment outside a smartphone. The system achieved detection limits of 15 ppb (Ni(II)), 7 ppb (Cu(II)), 2 ppb (Fe(III)), 20 ppb (Cr(VI)), 13 ppb (Pb(II)), 26 ppb (Hg(II)), and 15 ppb (Mn(II)) with six out of seven limits of detection values falling well below EPA regulatory guidelines for drinking water. The user-friendly Fill, Fold, Photo approach eliminates complex pretreatment steps. Smartphone-based detection offers portable quantification within seconds. Employing masking strategies ensured higher selectivity for each assay on the card, while our packaging protocols enable system stability for over 4 weeks of study, facilitating mass production and deployment within a realistic time frame. To validate the sensor's performance in real-world scenarios, the sensor was tested with environmental water samples. The sensor demonstrated good recovery, ranging from 77% to 94% compared to the standard ICP-MS method. Furthermore, spike recovery analysis confirmed the sensor's accuracy, with a relative standard deviation (RSD) of less than 15%. This technology holds significant promise for future development as a convenient, portable solution for field-based monitoring of a broad spectrum of water contaminants, including pesticides, PFAS, fertilizers, and beyond.
引用
收藏
页码:5479 / 5488
页数:10
相关论文
共 50 条
  • [21] Preconcentration and determination of trace amounts of heavy metals in natural water samples using a C18 cartridge and atomic absorption spectrometry
    Yamini, Y
    Ebrahimzadeh, H
    Chaloosi, M
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2002, 41 (05): : 991 - 995
  • [22] Automated Heavy Metals Detection in Water.
    Dupont, Marc
    Water Supply, 1986, 4 (04): : 159 - 172
  • [23] Is serum level of trace elements and heavy metals associated with threatened abortion?
    Lee, Yi-Le
    Horng, Huann-Cheng
    Wang, Peng-Hui
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2019, 82 (09) : 740 - 740
  • [24] PRECONCENTRATION OF TRACE-METALS FROM SEA-WATER WITH THE CHELATING RESIN CHELAMINE
    BLAIN, S
    APPRIOU, P
    HANDEL, H
    ANALYTICA CHIMICA ACTA, 1993, 272 (01) : 91 - 97
  • [25] Trace Level Detection of Water Contamination by SERS
    Jayawardhana, S.
    Mazzolini, A. P.
    Stoddart, P. R.
    XXII INTERNATIONAL CONFERENCE ON RAMAN SPECTROSCOPY, 2010, 1267 : 1063 - 1064
  • [26] Heavy metals determination in water and food samples after preconcentration by a new nanoporous adsorbent
    Hajiaghababaei, Leila
    Tajmiri, Tomaj
    Badiei, Alireza
    Ganjali, Mohammad Reza
    Khaniani, Yeganeh
    Ziarani, Ghodsi Mohammadi
    FOOD CHEMISTRY, 2013, 141 (03) : 1916 - 1922
  • [27] Synthesis of green nano sorbents for simultaneous preconcentration and recovery of heavy metals from water
    Sulejmanovic, Jasmina
    Memic, Mustafa
    Sehovic, Elma
    Omanovic, Rasim
    Begic, Sabina
    Pazalja, Mirha
    Ajanovic, Atifa
    Azhar, Ofaira
    Sher, Farooq
    CHEMOSPHERE, 2022, 296
  • [28] Signal enhancement of electrochemical DNA biosensors for the detection of trace heavy metals
    Sun, Jiadi
    Gan, Ying
    Liang, Tao
    Zhou, Shuqi
    Wang, Xinyi
    Wan, Hao
    Wang, Ping
    CURRENT OPINION IN ELECTROCHEMISTRY, 2019, 17 : 23 - 29
  • [29] DETERMINATION OF TRACE AMOUNTS OF METALS IN SALINE WATER BY ENERGY DISPERSIVE XRF USING NADDTC PRECONCENTRATION
    HOLYNSKA, B
    BISINIEK, K
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1976, 31 (01): : 159 - 166
  • [30] Reply to: "Is serum level of trace elements and heavy metals associated with threatened abortion?"
    Turan, Kasim
    Arslan, Ayse
    Uckan, Kazim
    Demir, Halit
    Demir, Canan
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2019, 82 (09) : 741 - 741