Validation and application of the square wave voltammetry method for the electrochemical determination of eszopiclone in pharmaceutical formulations and human biological fluids using glassy carbon electrode

被引:1
|
作者
Alghamdi, Ali F. [1 ]
机构
[1] Taibah Univ, Coll Sci, Chem Dept, Medina 30002, Saudi Arabia
关键词
Square wave voltammetry; Cyclic voltammetry; Differential pulse voltammetry; Reduction; Eszopiclone; GC electrode; PURE;
D O I
10.1016/j.jksus.2024.103408
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A buffer solution of Britton-Robinson (B-R) pH 6.5 was utilized to validate and apply a square wave voltammetry (SWV) method for the electrochemical determination of Eszopiclone (ESP) in pharmaceuticals and biological samples. The cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods were employed in the initial study of the voltammetric behavior of the ESP compound. The rotating glassy carbon (GC) indicator electrode (2.0 mm2), Pt auxiliary electrode, and Ag/AgCl reference electrode were used for ESP determination. ESP was analyzed to produce a sharp reduction peak at a potential of -750 mV. The best shape and high sensitivity of SWV cathodic current for ESP, were observed using GC electrode, B-R, pH 6.5, accumulation time (tacc) of 60-second, accumulation potential (Eacc) of - 0.1 V, amplitude voltage of 150 mV, frequency of 15 Hz, scan rate of 150 mV s-1, and stirrer rate of 1000 round per minute (rpm). The electroanalytical performance of the SWV method was evaluated through study of repeatability, stability, calibration curve, recovery, and limits of detection and quantification (LOD,LOQ). Under the optimal conditions, the SWV response was linear in the range from 3 x 10-6 to 5 x 10-5 mol/L (n = 10). The SWV method achieved a LOD of 1.9 x 10-8 mol/L (7.5 ppb), and a LOQ of 6.41 x 10- 8 mol L-1 (24.93 ppb). The validated SWV method was appeared the good repeatability, sensitivity and stability for the determination of ESP. It was given a very stable SWV current for 90 min, with a 0.141 % relative standard deviation (RSD%). The SWV method was applied to the determination of ESP in pharmaceutical tablets and biological samples.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Simple and rapid determination of clonidine in pharmaceutical samples by voltammetry using a bare glassy carbon electrode
    Moreira, Debora A. R.
    Pimentel, Dilton M.
    Arrieiro, Mariane O. B.
    Barbosa, Sandro L.
    da Silva, Rodrigo A. B.
    dos Santos, Wallans T. P.
    ELECTROANALYSIS, 2023, 35 (05)
  • [42] Electrochemical Behaviour of Trimebutine at Activated Glassy Carbon Electrode and its Direct Determination in Urine and Pharmaceutics by Square Wave and Differential Pulse Voltammetry
    Elqudaby, H. M.
    Mohamed, Gehad G.
    El Din, Ghada M. G.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (02): : 856 - 869
  • [43] Differential pulse voltammetry determination of acetaminophen and codeine in pharmaceutical formulations using a Mn/UiO-66 modified glassy carbon electrode
    Manh, Tran Duc
    Nguyen, Vo Thang
    Duyen, Vu Thi
    Nga, Nguyen Thi Thy
    Man, Nguyen Quang
    Thoa, Pham Thi Huyen
    Trinh, Le Huu
    Khieu, Dinh Quang
    JOURNAL OF NANOPARTICLE RESEARCH, 2023, 25 (09)
  • [44] SIMULTANEOUS DETERMINATION OF METHYL SALICYLATE AND THYMOL IN VARIOUS PHARMACEUTICAL FORMULATIONS BY DIFFERENTIAL-PULSE VOLTAMMETRY USING A GLASSY-CARBON ELECTRODE
    LAU, OW
    LUK, SF
    WONG, WC
    ANALYST, 1988, 113 (06) : 865 - 868
  • [45] Differential pulse voltammetry determination of acetaminophen and codeine in pharmaceutical formulations using a Mn/UiO-66 modified glassy carbon electrode
    Tran Duc Manh
    Vo Thang Nguyen
    Vu Thi Duyen
    Nguyen Thi Thy Nga
    Nguyen Quang Man
    Pham Thi Huyen Thoa
    Le Huu Trinh
    Dinh Quang Khieu
    Journal of Nanoparticle Research, 2023, 25
  • [46] Electroanalytical determination of donepezil HCl in tablets and human serum by differential pulse and osteryoung square wave voltammetry at a glassy carbon electrode
    Golcu, A.
    Ozkan, S. A.
    PHARMAZIE, 2006, 61 (09): : 760 - 765
  • [47] Application of Multi-Walled Carbon Nanotubes Modified Glassy Carbon Electrode for Determination of Mefenamic Acid in Pharmaceutical Preparations and Biological Fluids
    Afrasiabi, Mohammad
    Kianipour, Shokat
    Zad, Zeinab Rezayati
    Babei, Ali
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2013, 35 (04): : 1113 - 1121
  • [48] A non-toxic poly(resorcinol) modified glassy carbon electrode for highly selective square wave voltammetry determination of aspirin in tablet formulations and human urine samples
    Kassa, Adane
    Bitew, Zelalem
    Abebe, Atakilt
    SENSING AND BIO-SENSING RESEARCH, 2023, 39
  • [49] Determination of nitrofurantoin drug in pharmaceutical formulation and biological fluids by square-wave cathodic adsorptive stripping voltammetry
    Hammam, E
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (03) : 651 - 659
  • [50] Determination of vitamin E in margarines and edible oils using square wave anodic stripping voltammetry with a glassy carbon paste electrode
    Sys, Milan
    Svecova, Blanka
    Svancara, Ivan
    Metelka, Radovan
    FOOD CHEMISTRY, 2017, 229 : 621 - 627