Differential pulse voltammetry determination of acetaminophen and codeine in pharmaceutical formulations using a Mn/UiO-66 modified glassy carbon electrode

被引:1
|
作者
Manh, Tran Duc [1 ]
Nguyen, Vo Thang [1 ]
Duyen, Vu Thi [1 ]
Nga, Nguyen Thi Thy [1 ]
Man, Nguyen Quang [2 ]
Thoa, Pham Thi Huyen [3 ]
Trinh, Le Huu [4 ]
Khieu, Dinh Quang [5 ]
机构
[1] Univ Da Nang, Univ Educ & Sci, Da Nang City 550000, Vietnam
[2] Univ Med & Pharm, Hue Univ, Hue City 530000, Vietnam
[3] Tay Nguyen Univ, Fac Nat Sci & Technol, Buon Ma Thuot City 630000, Vietnam
[4] Nong Lam Univ, Fac Sci, Ho Chi Minh City 700000, Vietnam
[5] Hue Univ, Univ Sci, Hue City 530000, Vietnam
关键词
Acetaminophen; Codeine; Paracetamol; Mn/UiO-66; UiO-66; Nanostructures; Electrochemical sensor; Pharmaceutics; METAL-ORGANIC FRAMEWORK; ELECTROCHEMICAL SENSOR; DOPED UIO-66; PARACETAMOL; NANOPARTICLES; NANOCOMPOSITE; OXIDATION; CATALYSTS; MANGANESE; TRAMADOL;
D O I
10.1007/s11051-023-05839-7
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the present paper, Mn/UiO-66 material was synthesized by hydrothermal process. The obtained material was characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray (EDX) with mapping and nitrogen adsorption/desorption techniques. The doped manganese was shown to highly disperse and might be grafted into the lattice of UiO-66. A simple, fast, and inexpensive differential pulse voltammetric (DPV) method were developed using Mn/UiO-66 as an electrode modifier for the simultaneous determination of acetaminophen (ACE) and codeine (CDE) in pharmaceutical formulations. The experimental parameters, which might affect the peak currents of ACE and CDE, such as the pH of the solution, accumulation time, and scan rate, were optimized. Under optimal conditions, this technique provided low limits of detection for the quantification of ACE and CDE, of 0.45 and 0.31 & mu;M, respectively. The proposed DPV method was successfully applied to simultaneously determine ACE and CDE in samples of three pharmaceutical formulation with acceptable recoveries. Clearly, the proposed method might be an alternative option for the simultaneous determination of ACE and CDE.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Differential pulse voltammetry determination of acetaminophen and codeine in pharmaceutical formulations using a Mn/UiO-66 modified glassy carbon electrode
    Tran Duc Manh
    Vo Thang Nguyen
    Vu Thi Duyen
    Nguyen Thi Thy Nga
    Nguyen Quang Man
    Pham Thi Huyen Thoa
    Le Huu Trinh
    Dinh Quang Khieu
    Journal of Nanoparticle Research, 2023, 25
  • [2] Simultaneous voltammetric determination of ascorbic acid and acetaminophen in pharmaceutical formulations with UiO-66-modified glassy carbon electrode
    Nhi, Le Thi Thanh
    Tu, Nguyen Thi Thanh
    Hoa, Le Thi
    Toan, Tran Thanh Tam
    Van Thanh Son, Le
    Van Hung, Nguyen
    Tuyen, Tran Ngoc
    Khieu, Dinh Quang
    JOURNAL OF NANOPARTICLE RESEARCH, 2021, 23 (10)
  • [3] Simultaneous voltammetric determination of ascorbic acid and acetaminophen in pharmaceutical formulations with UiO-66-modified glassy carbon electrode
    Le Thi Thanh Nhi
    Nguyen Thi Thanh Tu
    Le Thi Hoa
    Tran Thanh Tam Toan
    Le Van Thanh Son
    Nguyen Van Hung
    Tran Ngoc Tuyen
    Dinh Quang Khieu
    Journal of Nanoparticle Research, 2021, 23
  • [4] Determination of Amlodipine in pharmaceutical formulations by differential-pulse voltammetry with a glassy carbon electrode
    Altiokka, G
    Dogrukol-Ak, D
    Tunçel, M
    Aboul-Enein, HY
    ARCHIV DER PHARMAZIE, 2002, 335 (2-3) : 104 - 108
  • [5] Determination of methylparaben by differential pulse voltammetry using a glassy carbon electrode modified with polypyrrole
    Madakbas, Seyfullah
    Kamiloglu, Senem
    Yetimoglu, Ece Kok
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (06) : 725 - 730
  • [6] Determination of methylparaben by differential pulse voltammetry using a glassy carbon electrode modified with polypyrrole
    Seyfullah Madakbaş
    Senem Kamiloǧlu
    Ece Kök Yetimoǧlu
    Journal of Analytical Chemistry, 2015, 70 : 725 - 730
  • [7] Differential pulse voltammetry for determination of benorilate in pharmaceutical formulations at carbon paste electrode
    Wang, CY
    Hu, XY
    Chen, Q
    Rong, G
    ANALYTICAL LETTERS, 2005, 38 (05) : 893 - 905
  • [8] DETERMINATION OF SALICYLIC-ACID IN PHARMACEUTICAL FORMULATIONS AND FOODS BY DIFFERENTIAL-PULSE VOLTAMMETRY USING A GLASSY-CARBON ELECTRODE
    FUNG, YS
    LUK, SF
    ANALYST, 1989, 114 (08) : 943 - 945
  • [9] Analysis of domperidone in pharmaceutical formulations and wastewater by differential pulse voltammetry at a glassy-carbon electrode
    M. S. El-Shahawi
    S. O. Bahaffi
    T. El-Mogy
    Analytical and Bioanalytical Chemistry, 2007, 387 : 719 - 725
  • [10] Analysis of domperidone in pharmaceutical formulations and wastewater by differential pulse voltammetry at a glassy-carbon electrode
    El-Shahawi, M. S.
    Bahaffi, S. O.
    El-Mogy, T.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (02) : 719 - 725