Differential pulse voltammetry determination of acetaminophen and codeine in pharmaceutical formulations using a Mn/UiO-66 modified glassy carbon electrode

被引:1
|
作者
Manh, Tran Duc [1 ]
Nguyen, Vo Thang [1 ]
Duyen, Vu Thi [1 ]
Nga, Nguyen Thi Thy [1 ]
Man, Nguyen Quang [2 ]
Thoa, Pham Thi Huyen [3 ]
Trinh, Le Huu [4 ]
Khieu, Dinh Quang [5 ]
机构
[1] Univ Da Nang, Univ Educ & Sci, Da Nang City 550000, Vietnam
[2] Univ Med & Pharm, Hue Univ, Hue City 530000, Vietnam
[3] Tay Nguyen Univ, Fac Nat Sci & Technol, Buon Ma Thuot City 630000, Vietnam
[4] Nong Lam Univ, Fac Sci, Ho Chi Minh City 700000, Vietnam
[5] Hue Univ, Univ Sci, Hue City 530000, Vietnam
关键词
Acetaminophen; Codeine; Paracetamol; Mn/UiO-66; UiO-66; Nanostructures; Electrochemical sensor; Pharmaceutics; METAL-ORGANIC FRAMEWORK; ELECTROCHEMICAL SENSOR; DOPED UIO-66; PARACETAMOL; NANOPARTICLES; NANOCOMPOSITE; OXIDATION; CATALYSTS; MANGANESE; TRAMADOL;
D O I
10.1007/s11051-023-05839-7
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the present paper, Mn/UiO-66 material was synthesized by hydrothermal process. The obtained material was characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray (EDX) with mapping and nitrogen adsorption/desorption techniques. The doped manganese was shown to highly disperse and might be grafted into the lattice of UiO-66. A simple, fast, and inexpensive differential pulse voltammetric (DPV) method were developed using Mn/UiO-66 as an electrode modifier for the simultaneous determination of acetaminophen (ACE) and codeine (CDE) in pharmaceutical formulations. The experimental parameters, which might affect the peak currents of ACE and CDE, such as the pH of the solution, accumulation time, and scan rate, were optimized. Under optimal conditions, this technique provided low limits of detection for the quantification of ACE and CDE, of 0.45 and 0.31 & mu;M, respectively. The proposed DPV method was successfully applied to simultaneously determine ACE and CDE in samples of three pharmaceutical formulation with acceptable recoveries. Clearly, the proposed method might be an alternative option for the simultaneous determination of ACE and CDE.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Differential pulse voltammetric determination of ciprofibrate in pharmaceutical formulations using a glassy carbon electrode modified with functionalized carbon nanotubes within a poly(allylamine hydrochloride) film
    Takeda, Humberto H.
    Janegitz, Bruno C.
    Medeiros, Roberta A.
    Mattoso, Luiz H. C.
    Fatibello-Filho, Orlando
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 755 - 760
  • [22] Determination of tetracycline residue in pork by differential pulse voltammetry using activated glassy carbon electrode
    Huong, Nguyen Thu
    Hien, Nguyen Thi Minh
    Thuy, Tran Thi Diem
    Ai, Nguyen Thi Ngoc
    Anh, Le Diep Quoc
    VIETNAM JOURNAL OF CHEMISTRY, 2023, 61 (01) : 65 - 73
  • [23] Electrochemical Determination of Chromium(VI) with Au/UiO-66 Modified Glassy Carbon and Screen-Printed Electrodes by Linear Sweep Voltammetry (LSV)
    Ding, Zhang-Jun
    Liu, Yao
    Weerasooriya, Rohan
    Chen, Xing
    ANALYTICAL LETTERS, 2024, 57 (05) : 753 - 771
  • [24] A Carbon Nanotube Modified Electrode for Determination of Caffeine by Differential Pulse Voltammetry
    Habibi, Biuck
    Abazari, Mehri
    Pournaghi-Azar, Mohammad Hossien
    CHINESE JOURNAL OF CATALYSIS, 2012, 33 (11) : 1783 - 1790
  • [25] Determination of melatonin by differential pulse voltammetry at modified carbon paste electrode
    Bekheit, GE
    ASIAN JOURNAL OF CHEMISTRY, 2000, 12 (02) : 541 - 547
  • [26] Trace mercury determination by differential pulse anodic stripping voltammetry using polythiophene-quinoline/glassy carbon modified electrode
    Yoo, KS
    Woo, SB
    Jyoung, JY
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2003, 24 (01) : 27 - 31
  • [27] Simultaneous Determination of Ascorbic Acid, Dopamine, and Uric Acid by Differential Pulse Voltammetry using Tiron Modified Glassy Carbon Electrode
    Ensafi, Ali A.
    Taei, M.
    Khayamian, Taghi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (01): : 116 - 130
  • [28] The Determination of Riboflavin (Vitamin B2) Using Manganese Dioxide Modified Glassy Carbon Electrode by Differential Pulse Voltammetry
    Huang, De-Qian
    Wu, Hai
    Song, Chongfu
    Zhu, Qiangqiang
    Zhang, Hong
    Sheng, Liang-Quan
    Xu, Hua-Jie
    Liu, Zhao-Di
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (09): : 8303 - 8312
  • [29] Differential Pulse Voltammetric Method for Determination of Acemetacin in Pharmaceutical Formulation using Glassy Carbon Electrode
    Moaaz, Eman M.
    Fayed, Ahmed S.
    Rezk, Mamdouh R.
    Abdel-Moety, Ezzat M.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2021, 13 (03): : 358 - 370
  • [30] Determination of trace procaine hydrochloride by differential pulse adsorptive stripping voltammetry with a nafion modified glassy carbon electrode
    Li, NB
    Duan, JP
    Chen, GN
    ANALYTICAL SCIENCES, 2003, 19 (12) : 1587 - 1592