A Wearable Accelerometer-Based System for Knee Angle Monitoring During Physiotherapy

被引:1
|
作者
Rufyid-u-Nissa, Rufyid-u [1 ,2 ,3 ]
Karmakar, Nemai C. [2 ,3 ]
Baghini, Maryam Shojaei [3 ]
机构
[1] IITB Monash Res Acad, Mumbai 400076, India
[2] Monash Univ, Dept Elect & Comp Syst Engn, Clayton, Vic 3800, Australia
[3] Indian Inst Technol, Dept Elect Engn, Mumbai 400076, India
关键词
External acceleration; gait assessment; inertial sensors; knee; magnetic disturbance; wearable sensors; MOTION; SENSOR; INTERVENTIONS; TECHNOLOGY; KINEMATICS; RANGE; GAIT;
D O I
10.1109/JSEN.2024.3396193
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Wearable inertial sensors can revolutionize the field of physiotherapy by enabling continuous remote assessment, early detection of mobility issues, and monitoring of recovery from injury or surgery. This can be achieved by integrating these sensors with onboard processors and a communication technology. In this work, we propose a wearable system that uses accelerometer data to obtain a clinical knee angle. The system comprises sensors on the thigh and shank along with embedded firmware. A simple accelerometer-inclination method was used to compute the thigh and shank angles, and the knee angle was calculated from these leg segment angles. The experimental results demonstrate that the proposed approach is sufficient for measuring the knee angle, obviating the need for additional sensors. This reduction in computational complexity was achieved without compromising the accuracy of knee angle computation. Measurements were performed in clinically relevant positions (supine, sitting, standing, and during level walking) to validate the system, and the results were compared with a video-based reference system. The measurements were closely aligned with the reference system, as indicated by the average root mean square error (RMSE) of 1.71 degrees for the exercises and 2.51 degrees for the leveled walk. This is an acceptable accuracy because the minimal clinically important difference (MCID) for the knee angle is 6 degrees. However, it was demonstrated that sensor placement can affect the accuracy. This portable, cost-effective, noninvasive, and embedded system, capable of continuous assessment in free-living environments, would be advantageous for acquiring quantitative patient data.
引用
收藏
页码:21417 / 21425
页数:9
相关论文
共 50 条
  • [41] Total knee replacement with an accelerometer-based, hand-held navigation system improves knee alignment: reliable in all patients
    Perico, Diego Alarcon
    Perez, Sergio F. Guarin
    Lee, Sheng-Hsun
    Warne, Christopher N.
    Hadley, Matthew
    Taunton, Michael J.
    Sierra, Rafael J.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (09) : 4125 - 4132
  • [42] Wireless dual accelerometer wearable system for torso-head angle measurement during walking
    Gurkan, Guray
    Onerge, Kubra
    Akalan, N. Ekin
    2018 26TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2018,
  • [43] Accelerometer-Based Step Regularity Is Lower in Older Adults with Bilateral Knee Osteoarthritis
    Barden, John M.
    Clermont, Christian A.
    Kobsar, Dylan
    Beauchet, Olivier
    FRONTIERS IN HUMAN NEUROSCIENCE, 2016, 10
  • [44] Development and Verification of an Accelerometer-Based Respiratory Detection Algorithm with Wearable Instrumented Smart Clothes
    Huang, Chih-Chieh
    Lin, Wen-Yen
    Lee, Ming-Yih
    2017 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2017, : 578 - 581
  • [45] Accelerometer-based body-position sensing for ambulatory electrocardiographic monitoring
    Ng, Jason
    Sahakian, Alan V.
    Swiryn, Steven
    Biomedical Instrumentation and Technology, 2003, 37 (05): : 338 - 346
  • [46] Accelerometer-Based Speed-Adaptive Gait Authentication Method for Wearable IoT Devices
    Sun, Fangmin
    Mao, Chenfei
    Fan, Xiaomao
    Li, Ye
    IEEE INTERNET OF THINGS JOURNAL, 2019, 6 (01) : 820 - 830
  • [47] Validation of a Wearable Accelerometer-Based Activity Monitor for Use in Future Osteoporosis Prevention Programs
    Sanchez-Trigo, Horacio
    Jesus Sanchez-Oliver, Antonio
    Abt, Grant
    Sanudo, Borja
    SUSTAINABILITY, 2020, 12 (06)
  • [48] Exploring occupational standing activities using accelerometer-based activity monitoring
    Anderson, Jennifer
    Granat, Malcolm H.
    Williams, Anita E.
    Nester, Christopher
    ERGONOMICS, 2019, 62 (08) : 1055 - 1065
  • [49] Selective Device Activation for Power Reduction in Accelerometer-Based Wearable Guidance Systems for The Blind
    Lee, YeongJu
    Song, Minseok
    2012 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS (ICCE), 2012, : 106 - 107
  • [50] Measuring gait with an accelerometer-based wearable: influence of device location, testing protocol and age
    Del Din, Silvia
    Hickey, Aodhan
    Hurwitz, Naomi
    Mathers, John C.
    Rochester, Lynn
    Godfrey, Alan
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (10) : 1785 - 1797