A Wearable Accelerometer-Based System for Knee Angle Monitoring During Physiotherapy

被引:1
|
作者
Rufyid-u-Nissa, Rufyid-u [1 ,2 ,3 ]
Karmakar, Nemai C. [2 ,3 ]
Baghini, Maryam Shojaei [3 ]
机构
[1] IITB Monash Res Acad, Mumbai 400076, India
[2] Monash Univ, Dept Elect & Comp Syst Engn, Clayton, Vic 3800, Australia
[3] Indian Inst Technol, Dept Elect Engn, Mumbai 400076, India
关键词
External acceleration; gait assessment; inertial sensors; knee; magnetic disturbance; wearable sensors; MOTION; SENSOR; INTERVENTIONS; TECHNOLOGY; KINEMATICS; RANGE; GAIT;
D O I
10.1109/JSEN.2024.3396193
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Wearable inertial sensors can revolutionize the field of physiotherapy by enabling continuous remote assessment, early detection of mobility issues, and monitoring of recovery from injury or surgery. This can be achieved by integrating these sensors with onboard processors and a communication technology. In this work, we propose a wearable system that uses accelerometer data to obtain a clinical knee angle. The system comprises sensors on the thigh and shank along with embedded firmware. A simple accelerometer-inclination method was used to compute the thigh and shank angles, and the knee angle was calculated from these leg segment angles. The experimental results demonstrate that the proposed approach is sufficient for measuring the knee angle, obviating the need for additional sensors. This reduction in computational complexity was achieved without compromising the accuracy of knee angle computation. Measurements were performed in clinically relevant positions (supine, sitting, standing, and during level walking) to validate the system, and the results were compared with a video-based reference system. The measurements were closely aligned with the reference system, as indicated by the average root mean square error (RMSE) of 1.71 degrees for the exercises and 2.51 degrees for the leveled walk. This is an acceptable accuracy because the minimal clinically important difference (MCID) for the knee angle is 6 degrees. However, it was demonstrated that sensor placement can affect the accuracy. This portable, cost-effective, noninvasive, and embedded system, capable of continuous assessment in free-living environments, would be advantageous for acquiring quantitative patient data.
引用
收藏
页码:21417 / 21425
页数:9
相关论文
共 50 条
  • [31] A Review of Accelerometer-based Activity Monitoring in Cancer Survivorship Research
    Peddle-Mcintyre, Carolyn J.
    Cavalheri, Vinicius
    Boyle, Terry
    Mcveigh, Joanne A.
    Jeffery, Emily
    Lynch, Brigid M.
    Vallance, Jeff K.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (09): : 1790 - 1801
  • [32] ACCELEROMETER-BASED FALL DETECTION SENSOR SYSTEM FOR THE ELDERLY
    Li, Yanjun
    Chen, Gan
    Shen, Yueyun
    Zhu, Yihua
    Cheng, Zhen
    2012 IEEE 2ND INTERNATIONAL CONFERENCE ON CLOUD COMPUTING AND INTELLIGENT SYSTEMS (CCIS) VOLS 1-3, 2012, : 1216 - 1220
  • [33] Radiographic Results of an Accelerometer-based, Handheld Surgical Navigation System for the Tibial Resection in Total Knee Arthroplasty
    Nam, Denis
    Cross, Michael
    Deshmane, Prashant
    Jerabek, Seth
    Kang, Michael
    Mayman, David J.
    ORTHOPEDICS, 2011, 34 (10) : E615 - E621
  • [34] An Accelerometer-based Wearable Multi-node Motion Detection System of Freezing of Gait in Parkinson's Disease
    Liu, Chen
    Han, Lingmin
    Chang, Siyuan
    Wang, Jiang
    2022 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2022), 2022,
  • [35] Improved implant alignment accuracy with an accelerometer-based portable navigation system in medial unicompartmental knee arthroplasty
    Yoshihito Suda
    Koji Takayama
    Kazunari Ishida
    Shinya Hayashi
    Shingo Hashimoto
    Takahiro Niikura
    Takehiko Matsushita
    Ryosuke Kuroda
    Tomoyuki Matsumoto
    Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 2917 - 2923
  • [36] Improved implant alignment accuracy with an accelerometer-based portable navigation system in medial unicompartmental knee arthroplasty
    Suda, Yoshihito
    Takayama, Koji
    Ishida, Kazunari
    Hayashi, Shinya
    Hashimoto, Shingo
    Niikura, Takahiro
    Matsushita, Takehiko
    Kuroda, Ryosuke
    Matsumoto, Tomoyuki
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (09) : 2917 - 2923
  • [37] An Accelerometer-Based Real-Time Monitoring and Leak Detection System for Pressurized Water Pipelines
    El Zahab, Samer
    Mosleh, Fadi
    Zayed, Tarek
    PIPELINES 2016 - OUT OF SIGHT, OUT OF MIND, NOT OUT OF RISK, 2016, : 257 - 268
  • [38] B-CNN: a deep learning method for accelerometer-based fatigue cracks monitoring system
    Yanjie Zhu
    Hidehiko Sekiya
    Takayuki Okatani
    Masayuki Tai
    Shogo Morichika
    Journal of Civil Structural Health Monitoring, 2023, 13 : 947 - 959
  • [39] B-CNN: a deep learning method for accelerometer-based fatigue cracks monitoring system
    Zhu, Yanjie
    Sekiya, Hidehiko
    Okatani, Takayuki
    Tai, Masayuki
    Morichika, Shogo
    JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2023, 13 (4-5) : 947 - 959
  • [40] The design of a real-time accelerometer-based baby sleeping position monitoring and correction system
    Sudharsanan, S.
    Karthikeyan, B.