A Wearable Accelerometer-Based System for Knee Angle Monitoring During Physiotherapy

被引:1
|
作者
Rufyid-u-Nissa, Rufyid-u [1 ,2 ,3 ]
Karmakar, Nemai C. [2 ,3 ]
Baghini, Maryam Shojaei [3 ]
机构
[1] IITB Monash Res Acad, Mumbai 400076, India
[2] Monash Univ, Dept Elect & Comp Syst Engn, Clayton, Vic 3800, Australia
[3] Indian Inst Technol, Dept Elect Engn, Mumbai 400076, India
关键词
External acceleration; gait assessment; inertial sensors; knee; magnetic disturbance; wearable sensors; MOTION; SENSOR; INTERVENTIONS; TECHNOLOGY; KINEMATICS; RANGE; GAIT;
D O I
10.1109/JSEN.2024.3396193
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Wearable inertial sensors can revolutionize the field of physiotherapy by enabling continuous remote assessment, early detection of mobility issues, and monitoring of recovery from injury or surgery. This can be achieved by integrating these sensors with onboard processors and a communication technology. In this work, we propose a wearable system that uses accelerometer data to obtain a clinical knee angle. The system comprises sensors on the thigh and shank along with embedded firmware. A simple accelerometer-inclination method was used to compute the thigh and shank angles, and the knee angle was calculated from these leg segment angles. The experimental results demonstrate that the proposed approach is sufficient for measuring the knee angle, obviating the need for additional sensors. This reduction in computational complexity was achieved without compromising the accuracy of knee angle computation. Measurements were performed in clinically relevant positions (supine, sitting, standing, and during level walking) to validate the system, and the results were compared with a video-based reference system. The measurements were closely aligned with the reference system, as indicated by the average root mean square error (RMSE) of 1.71 degrees for the exercises and 2.51 degrees for the leveled walk. This is an acceptable accuracy because the minimal clinically important difference (MCID) for the knee angle is 6 degrees. However, it was demonstrated that sensor placement can affect the accuracy. This portable, cost-effective, noninvasive, and embedded system, capable of continuous assessment in free-living environments, would be advantageous for acquiring quantitative patient data.
引用
收藏
页码:21417 / 21425
页数:9
相关论文
共 50 条
  • [1] Evaluating an Accelerometer-Based System for Spine Shape Monitoring
    Stollenwerk, Katharina
    Muellers, Johannes
    Mueller, Jonas
    Hinkenjann, Andre
    Krueger, Bjoern
    COMPUTATIONAL SCIENCE AND ITS APPLICATIONS - ICCSA 2018, PT IV, 2018, 10963 : 740 - 756
  • [2] Accelerometer-Based Angle Measurement System With Application in Hospital Bed
    Sueaseenak, Direk
    Namjirachot, Nattapon
    Sukkit, Kiattisak
    2015 8TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2015,
  • [3] Supervised Expert System for Wearable MEMS Accelerometer-Based Fall Detector
    Rescio, Gabriele
    Leone, Alessandro
    Siciliano, Pietro
    JOURNAL OF SENSORS, 2013, 2013
  • [4] Subcutaneous Accelerometer-Based Monitoring of Respiration
    Alvarez, Rafael Cordero
    Joubert, Pierre-Yves
    Feuerstein, Delphine
    2019 13TH INTERNATIONAL SYMPOSIUM ON MEDICAL INFORMATION AND COMMUNICATION TECHNOLOGY (ISMICT), 2019, : 75 - 80
  • [5] Usefulness of an Accelerometer-Based Portable Navigation System for Total Knee Arthroplasty
    Minoda, Yukihide
    Hayakawa, Kazue
    Hagio, Keisuke
    Konishi, Natsuo
    Tamaki, Tatsuya
    Iwakiri, Kentaro
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2020, 102 (22): : 1993 - 2000
  • [6] Usefulness of an accelerometer-based portable navigation system in total knee arthroplasty
    Ikawa, T.
    Takemura, S.
    Kim, M.
    Takaoka, K.
    Minoda, Y.
    Kadoya, Y.
    BONE & JOINT JOURNAL, 2017, 99B (08): : 1047 - 1052
  • [7] Classification of knee arthropathy with accelerometer-based vibroarthrography
    Moreira, Dinis
    Silva, Joana
    Correia, Miguel V.
    Massada, Marta
    PHEALTH 2016, 2016, 224 : 33 - 39
  • [8] A description of an accelerometer-based mobility monitoring technique
    Lyons, GM
    Culhane, KM
    Hilton, D
    Grace, PA
    Lyons, D
    MEDICAL ENGINEERING & PHYSICS, 2005, 27 (06) : 497 - 504
  • [9] Validation of a Novel Smartphone Accelerometer-Based Knee Goniometer
    Ockendon, Matthew
    Gilbert, Robin E.
    JOURNAL OF KNEE SURGERY, 2012, 25 (04) : 341 - 345
  • [10] An accelerometer-based leak detection system
    El-Zahab, Samer
    Abdelkader, Eslam Mohammed
    Zayed, Tarek
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2018, 108 : 276 - 291