Feasibility of rib fracture detection in low-dose computed tomography images with a large, multicenter datasets-based model

被引:1
|
作者
Jin, Liang [1 ,2 ]
Youjun, E. [3 ]
Ye, Zheng [4 ]
Gao, Pan [1 ]
Wei, Guoliang [3 ]
Zhang, Jia qi [3 ]
Li, Ming [1 ,2 ,5 ]
机构
[1] Affiliated Fudan Univ, Huadong Hosp, Radiol Dept, 221 West Yanan Rd, Shanghai, Peoples R China
[2] Affiliated Fudan Univ, Huashan Hosp, Radiol Dept, Shanghai, Peoples R China
[3] Yizhun Med Technol Beijing Co Ltd, Beijing, Peoples R China
[4] Shanghai Changfeng Community Hlth Serv Ctr, Shanghai, Peoples R China
[5] Inst Funct & Mol Med Imaging, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Low; -dose; Rib fracture; Deep learning; Multicenter; CT; CT; TRAUMA;
D O I
10.1016/j.heliyon.2024.e31010
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To evaluate the feasibility of rib fracture detection in low-dose computed tomography (CT) images with a RetinaNet-based approach and to evaluate the potential of lowdose CT for rib fracture detection compared with regular-dose CT images. Materials and methods: The RetinaNet-based deep learning model was trained using 7300 scans with 50,410 rib fractures that were used as internal training datasets from four multicenter. The external test datasets consisted of both regular-dose and low-dose chest-abdomen CT images of rib fractures; the MICCAI 2020 RibFrac Challenge Dataset was used as the public dataset. Radiologists' interpretations were used as reference standards. The performance of the model in rib fracture detection was compared with the radiologists' interpretation. Results: In total, 728 traumatic rib fractures of 100 patients [60 men (60 %); mean age, 53.45 +/- 11.19 (standard deviation (SD)); range, 18-77 years] were assessed in the external datasets. In these patients, the regular-dose group had a mean CT dose index volume (CTDIvol) of 7.18 mGy (SD: 2.22) and a mean dose length product (DLP) of 305.38 mGy cm (SD: 95.31); the low-dose group had a mean CTDIvol of 2.79 mGy (SD: 1.11) and a mean DLP of 131.52 mGy cm (SD: 55.58). The sensitivity of the RetinaNet-based model and that of the radiologists was 0.859 and 0.721 in the low-dose CT images and 0.886 and 0.794 in the regular-dose CT images, respectively. Conclusions: These findings indicate that the RetinaNet-based model can detect rib fractures in low-dose CT images with a robust performance, indicating its feasibility in assisting radiologists with rib fracture diagnosis.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] A novel multimodal prediction model based on DNA methylation biomarkers and low-dose computed tomography images for identifying early-stage lung cancer
    Jing Zhang
    Haohua Yao
    Chunliu Lai
    Xue Sun
    Xiujuan Yang
    Shurong Li
    Yubiao Guo
    Junhang Luo
    Zhihua Wen
    Kejing Tang
    Chinese Journal of Cancer Research, 2023, 35 (05) : 511 - 526
  • [42] A novel multimodal prediction model based on DNA methylation biomarkers and low-dose computed tomography images for identifying early-stage lung cancer
    Zhang, Jing
    Yao, Haohua
    Lai, Chunliu
    Sun, Xue
    Yang, Xiujuan
    Li, Shurong
    Guo, Yubiao
    Luo, Junhang
    Wen, Zhihua
    Tang, Kejing
    CHINESE JOURNAL OF CANCER RESEARCH, 2023, 35 (05) : 511 - +
  • [43] Beyond Low-Dose Computed Tomography: Emerging Diagnostic Tools for Early Lung Cancer Detection
    Yang, Ching-Yao
    Lee, Meng-Rui
    Yang, Pan-Chyr
    JOURNAL OF THORACIC ONCOLOGY, 2024, 19 (09) : 1261 - 1264
  • [44] Low-dose computed tomography in workers previously exposed to asbestos: Detection of parenchymal lung disease
    Patsios, D.
    Bayanati, H.
    Johnston, M.
    Paul, N.
    Roberts, H.
    LUNG CANCER, 2006, 54 : S38 - S38
  • [45] Low-Dose Computed Tomography for the Detection of Cocaine Body Packs: Clinical Evaluation and Legal Issues
    Pache, G.
    Einhaus, D.
    Bulla, S.
    Baumann, T.
    Langer, M.
    Blanke, P.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (02): : 122 - 129
  • [46] Promotion of low-dose computed tomography for early-stage lung cancer detection.
    Vela, Monica Saravana
    Berei, Joseph
    Dovalovsky, Katrina
    Sreenivasappa, Shylendra
    Ross, Joseph
    Moruzzi, Luigi
    Martell, Sandra
    Schulz, William
    Puri, Neelu
    CANCER RESEARCH, 2021, 81 (13)
  • [47] Promotion of low-dose computed tomography for early-stage lung cancer detection.
    Gautam, Shruti
    DeVera, Roberto E.
    Patel, Meet
    CANCER RESEARCH, 2022, 82 (12)
  • [48] Early detection of lung cancer with low-dose computed tomography: an update on recently presented data
    Devaraj, Anand
    Field, John K.
    LUNG CANCER MANAGEMENT, 2012, 1 (03) : 189 - 194
  • [49] Weakly supervised low-dose computed tomography denoising based on generative adversarial networks
    Liao, Peixi
    Zhang, Xucan
    Wu, Yaoyao
    Chen, Hu
    Du, Wenchao
    Liu, Hong
    Yang, Hongyu
    Zhang, Yi
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (08) : 5571 - 5590
  • [50] Non-Local Total Variation based Low-Dose Computed Tomography Denoising
    Hashemi, SayedMasoud
    Beheshti, Soosan
    Cobbold, Richard S. C.
    Paul, Narinder S.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 1083 - 1086