Feasibility of rib fracture detection in low-dose computed tomography images with a large, multicenter datasets-based model

被引:1
|
作者
Jin, Liang [1 ,2 ]
Youjun, E. [3 ]
Ye, Zheng [4 ]
Gao, Pan [1 ]
Wei, Guoliang [3 ]
Zhang, Jia qi [3 ]
Li, Ming [1 ,2 ,5 ]
机构
[1] Affiliated Fudan Univ, Huadong Hosp, Radiol Dept, 221 West Yanan Rd, Shanghai, Peoples R China
[2] Affiliated Fudan Univ, Huashan Hosp, Radiol Dept, Shanghai, Peoples R China
[3] Yizhun Med Technol Beijing Co Ltd, Beijing, Peoples R China
[4] Shanghai Changfeng Community Hlth Serv Ctr, Shanghai, Peoples R China
[5] Inst Funct & Mol Med Imaging, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Low; -dose; Rib fracture; Deep learning; Multicenter; CT; CT; TRAUMA;
D O I
10.1016/j.heliyon.2024.e31010
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To evaluate the feasibility of rib fracture detection in low-dose computed tomography (CT) images with a RetinaNet-based approach and to evaluate the potential of lowdose CT for rib fracture detection compared with regular-dose CT images. Materials and methods: The RetinaNet-based deep learning model was trained using 7300 scans with 50,410 rib fractures that were used as internal training datasets from four multicenter. The external test datasets consisted of both regular-dose and low-dose chest-abdomen CT images of rib fractures; the MICCAI 2020 RibFrac Challenge Dataset was used as the public dataset. Radiologists' interpretations were used as reference standards. The performance of the model in rib fracture detection was compared with the radiologists' interpretation. Results: In total, 728 traumatic rib fractures of 100 patients [60 men (60 %); mean age, 53.45 +/- 11.19 (standard deviation (SD)); range, 18-77 years] were assessed in the external datasets. In these patients, the regular-dose group had a mean CT dose index volume (CTDIvol) of 7.18 mGy (SD: 2.22) and a mean dose length product (DLP) of 305.38 mGy cm (SD: 95.31); the low-dose group had a mean CTDIvol of 2.79 mGy (SD: 1.11) and a mean DLP of 131.52 mGy cm (SD: 55.58). The sensitivity of the RetinaNet-based model and that of the radiologists was 0.859 and 0.721 in the low-dose CT images and 0.886 and 0.794 in the regular-dose CT images, respectively. Conclusions: These findings indicate that the RetinaNet-based model can detect rib fractures in low-dose CT images with a robust performance, indicating its feasibility in assisting radiologists with rib fracture diagnosis.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Radiomic-Based Lung Nodule Classification in Low-Dose Computed Tomography
    Wojciech, Prazuch
    Jelitto-Gorska, Malgorzata
    Durawa, Agata
    Dziadziuszko, Katarzyna
    Polanska, Joanna
    BIOINFORMATICS AND BIOMEDICAL ENGINEERING, PT I, 2022, : 357 - 363
  • [32] Detection of low-dose computed tomography pulmonary nodules based on 3D CNN-CapsNet
    Song, Li
    Zhang, Ming
    Wu, Liang
    ELECTRONICS LETTERS, 2023, 59 (18)
  • [33] Feasibility study on many-view under-sampling technique for low-dose computed tomography
    Cho, Seungryong
    Lee, Taewon
    Min, Jonghwan
    Chung, Hyekyun
    OPTICAL ENGINEERING, 2012, 51 (08)
  • [34] Low-dose computed tomography of urolithiasis in obese patients: a feasibility study to evaluate image reconstruction algorithms
    Chang, De-Hua
    Slebocki, Karin
    Khristenko, Ekaterina
    Herden, Jan
    Salem, Johannes
    Hokamp, Nils Grosse
    Mammadov, Kamal
    Hellmich, Martin
    Kabbasch, Christoph
    DIABETES METABOLIC SYNDROME AND OBESITY-TARGETS AND THERAPY, 2019, 12 : 439 - 445
  • [35] Low-dose radiation with 80-kVp computed tomography to diagnose pulmonary embolism: a feasibility study
    Nyman, Ulf
    Bjorkdahl, Peter
    Olsson, Marie-Louise
    Gunnarsson, Mikael
    Goldman, Bitte
    ACTA RADIOLOGICA, 2012, 53 (09) : 1004 - 1013
  • [36] Three-year findings of an early lung cancer detection feasibility study with low-dose spiral computed tomography in heavy smokers
    Novello, S
    Selvaggi, G
    Perotto, F
    Lausi, P
    Dogliotti, L
    Borasio, R
    Ferraris, F
    Saini, A
    Fava, C
    Scagliotti, G
    LUNG CANCER, 2005, 49 : S185 - S185
  • [37] Three-year findings of an early lung cancer detection feasibility study with low-dose spiral computed tomography in heavy smokers
    Novello, S
    Fava, C
    Borasio, P
    Dogliotti, L
    Cortese, G
    Crida, B
    Selvaggi, G
    Lausi, P
    Brizzi, MP
    Sperone, P
    Cardinale, L
    Ferraris, F
    Perotto, F
    Priola, A
    Scagliotti, GV
    ANNALS OF ONCOLOGY, 2005, 16 (10) : 1662 - 1666
  • [38] Physics-/Model-Based and Data-Driven Methods for Low-Dose Computed Tomography: A survey
    Xia, Wenjun
    Shan, Hongming
    Wang, Ge
    Zhang, Yi
    IEEE SIGNAL PROCESSING MAGAZINE, 2023, 40 (02) : 89 - 100
  • [39] A region-adaptive non-local denoising algorithm for low-dose computed tomography images
    Zhang, Pengcheng
    Liu, Yi
    Gui, Zhiguo
    Chen, Yang
    Jia, Lina
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2023, 20 (02) : 2831 - 2846
  • [40] Deep Learning Denoising of Low-Dose Computed Tomography Chest Images: A Quantitative and Qualitative Image Analysis
    Azour, Lea
    Hu, Yunan
    Ko, Jane P.
    Chen, Baiyu
    Knoll, Florian
    Alpert, Jeffrey B.
    Brusca-Augello, Geraldine
    Mason, Derek M.
    Wickstrom, Maj L.
    Kwon, Young Joon
    Babb, James
    Liang, Zhengrong
    Moore, William H.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (02) : 212 - 219