Feasibility of rib fracture detection in low-dose computed tomography images with a large, multicenter datasets-based model

被引:1
|
作者
Jin, Liang [1 ,2 ]
Youjun, E. [3 ]
Ye, Zheng [4 ]
Gao, Pan [1 ]
Wei, Guoliang [3 ]
Zhang, Jia qi [3 ]
Li, Ming [1 ,2 ,5 ]
机构
[1] Affiliated Fudan Univ, Huadong Hosp, Radiol Dept, 221 West Yanan Rd, Shanghai, Peoples R China
[2] Affiliated Fudan Univ, Huashan Hosp, Radiol Dept, Shanghai, Peoples R China
[3] Yizhun Med Technol Beijing Co Ltd, Beijing, Peoples R China
[4] Shanghai Changfeng Community Hlth Serv Ctr, Shanghai, Peoples R China
[5] Inst Funct & Mol Med Imaging, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Low; -dose; Rib fracture; Deep learning; Multicenter; CT; CT; TRAUMA;
D O I
10.1016/j.heliyon.2024.e31010
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To evaluate the feasibility of rib fracture detection in low-dose computed tomography (CT) images with a RetinaNet-based approach and to evaluate the potential of lowdose CT for rib fracture detection compared with regular-dose CT images. Materials and methods: The RetinaNet-based deep learning model was trained using 7300 scans with 50,410 rib fractures that were used as internal training datasets from four multicenter. The external test datasets consisted of both regular-dose and low-dose chest-abdomen CT images of rib fractures; the MICCAI 2020 RibFrac Challenge Dataset was used as the public dataset. Radiologists' interpretations were used as reference standards. The performance of the model in rib fracture detection was compared with the radiologists' interpretation. Results: In total, 728 traumatic rib fractures of 100 patients [60 men (60 %); mean age, 53.45 +/- 11.19 (standard deviation (SD)); range, 18-77 years] were assessed in the external datasets. In these patients, the regular-dose group had a mean CT dose index volume (CTDIvol) of 7.18 mGy (SD: 2.22) and a mean dose length product (DLP) of 305.38 mGy cm (SD: 95.31); the low-dose group had a mean CTDIvol of 2.79 mGy (SD: 1.11) and a mean DLP of 131.52 mGy cm (SD: 55.58). The sensitivity of the RetinaNet-based model and that of the radiologists was 0.859 and 0.721 in the low-dose CT images and 0.886 and 0.794 in the regular-dose CT images, respectively. Conclusions: These findings indicate that the RetinaNet-based model can detect rib fractures in low-dose CT images with a robust performance, indicating its feasibility in assisting radiologists with rib fracture diagnosis.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Deep-learning algorithm for rib fracture detection in low-dose chest CT images
    Yu, Hui
    Ding, Yongzheng
    Sun, Jinglai
    Yu, Xuyao
    Zhu, Fengling
    Li, Huanming
    Liang, Xiaoyun
    Jia, Dagong
    2022 9TH INTERNATIONAL CONFERENCE ON BIOMEDICAL AND BIOINFORMATICS ENGINEERING, ICBBE 2022, 2022, : 55 - 60
  • [2] Feasibility of ultra low-dose coronary computed tomography angiography
    McGraw, Sloane
    Carlson, Claire
    Grant, Katharine
    Nijjar, Prabhjot S.
    INDIAN HEART JOURNAL, 2018, 70 (03) : 443 - 445
  • [3] Low-Dose Computed Tomography Coronary Angiography With Prospective Electrocardiogram Triggering Feasibility in a Large Population
    Buechel, Ronny R.
    Husmann, Lars
    Herzog, Bernhard A.
    Pazhenkottil, Aju P.
    Nkoulou, Rene
    Ghadri, Jelena R.
    Treyer, Valerie
    von Schulthess, Patrick
    Kaufmann, Philipp A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (03) : 332 - 336
  • [4] Simulated Low-Dose Computed Tomography in Oncological Patients: A Feasibility Study
    Yamamura, Jin
    Tornquist, Katharina
    Buchert, Ralph
    Wildberger, Joachim
    Nagel, H. D.
    Dichtl, Daniela
    Adam, Gerhard
    Wedegaertner, Ulrike
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (02) : 302 - 308
  • [5] Rib fracture detection in computed tomography images using deep convolutional neural networks
    Kaiume, Masafumi
    Suzuki, Shigeru
    Yasaka, Koichiro
    Sugawara, Haruto
    Shen, Yun
    Katada, Yoshiaki
    Ishikawa, Takuya
    Fukui, Rika
    Abe, Osamu
    MEDICINE, 2021, 100 (20) : E26024
  • [6] Automated detection of lung nodules in low-dose computed tomography
    Cascio, D.
    Cheran, S. C.
    Chincarini, A.
    De Nunzio, G.
    Delogu, P.
    Fantacci, M. E.
    Gargano, G.
    Gori, I.
    Masala, G. L.
    Martinez, A. Preite
    Retico, A.
    Santoro, M.
    Spinelli, C.
    Tarantino, T.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S357 - S359
  • [7] Detection of bronchocoronary collateral by low-dose multidetector computed tomography
    Pontone, Gianluca
    Grancini, Luca
    Andreini, Daniele
    Pepi, Mauro
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 40 (01) : 272 - 272
  • [8] Characteristics of Rib Fractures in Child AbuseThe Role of Low-Dose Chest Computed Tomography
    Sanchez, Thomas R.
    Grasparil, Angelo D.
    Chaudhari, Ruchir
    Coulter, Kevin P.
    Wootton-Gorges, Sandra L.
    PEDIATRIC EMERGENCY CARE, 2018, 34 (02) : 81 - 83
  • [9] A Comprehensive Review of GAN-Based Denoising Models for Low-Dose Computed Tomography Images
    Sandhu, Manbir
    Kushwaha, Sumit
    Arora, Tanvi
    INTERNATIONAL JOURNAL OF IMAGE AND GRAPHICS, 2023,
  • [10] Standard Versus Low-Dose Computed Tomography for Assessment of Acetabular Fracture Reduction
    Gibbs, Stephen
    Carney, John
    Erdman, Mary K.
    Telis, Alexander
    Lee, Adam K.
    Fleming, Mark E.
    Lee, Jackson
    White, Eric
    Marecek, Geoffrey S.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (09) : 462 - 468