Evaluation of the Vitek® Reveal™ system for rapid antimicrobial susceptibility testing of Gram-negative pathogens, including ESBL, CRE and CRAB, from positive blood cultures

被引:1
|
作者
Antonelli, Alberto [1 ,2 ,3 ]
Cuffari, Sara [1 ,2 ]
Casciato, Benedetta [1 ,2 ]
Giani, Tommaso [1 ,2 ,3 ]
Rossolini, Gian Maria [1 ,2 ,3 ]
机构
[1] Univ Florence, Dept Expt & Clin Med, Florence, Italy
[2] Careggi Univ Hosp, Microbiol & Virol Unit, Florence, Italy
[3] Univ Florence, IRCCS Don Gnocchi Fdn, NARR Joint Lab Antimicrobial Resistance Res & Cont, Florence, Italy
关键词
Rapid AST; CRE; CRAB; Bloodstream infections; KLEBSIELLA-PNEUMONIAE; IDENTIFICATION; TIME;
D O I
10.1016/j.diagmicrobio.2024.116503
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Blood culture (BC) remains the reference diagnostic tool for bloodstream infections but is hampered by long turnaround time (TAT). This study evaluated the Vitek (R) RevealTM (VR) system for rapid antimicrobial susceptibility testing (AST) with 72 cases of monomicrobial BCs (55 Enterobacterales, 12 Pseudomonas aeruginosa and 5 Acinetobacter baumannii), including isolates producing carbapenemases and/or extended-spectrum beta-lactamases. VR returned AST results with a mean TAT of 5.4 h. Compared to a conventional workflow based on broth microdilution, VR exhibited essential agreement (EA) and category agreement (CA) >90 % in most cases, except with meropenem for Enterobacterales (CA, 85.5 %), piperacillin/tazobactam for P. aeruginosa (EA, 83.3 %), and trimethoprim/sulfamethoxazole for A. baumannii (CA and EA, 80 %). Bias exhibited an underestimation trend with ceftazidime/avibactam (-78.9 %) and ceftazidime (-50 %) for Enterobacterales and P. aeruginosa, respectively. Overall, VR appears an interesting tool to decrease TAT of the BC workflow, although further evaluation with some antibiotic-pathogen combinations would be warranted.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Verification of the Vitek Reveal System for Direct Antimicrobial Susceptibility Testing in Gram-Negative Positive Blood Cultures
    Menchinelli, Giulia
    Squitieri, Damiano
    Magri, Carlotta
    De Maio, Flavio
    D'Inzeo, Tiziana
    Cacaci, Margherita
    De Angelis, Giulia
    Sanguinetti, Maurizio
    Posteraro, Brunella
    ANTIBIOTICS-BASEL, 2024, 13 (11):
  • [2] Performance evaluation of the Specific Reveal system for rapid antibiotic susceptibility testing from positive blood cultures containing Gram-negative pathogens
    Ostermann, Greta
    Koerber-Irrgang, Barbara
    Krueger, Alexander
    Singh, Pragya
    Vo, Kenny
    Gielen, Joerg
    Aurbach, Ute
    Wisplinghoff, Hilmar
    Jazmati, Nathalie
    JOURNAL OF CLINICAL MICROBIOLOGY, 2024, 62 (12)
  • [3] Evaluation of the VITEK 2 system for rapid direct identification and susceptibility testing of gram-negative bacilli from positive blood cultures
    Ling, TKW
    Liu, ZK
    Cheng, AFB
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (10) : 4705 - 4707
  • [4] Rapid antimicrobial susceptibility testing by VITEK®2 directly from blood cultures in patients with Gram-negative rod bacteremia
    Hogan, C. A.
    Watz, N.
    Budvytiene, I.
    Banaei, N.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2019, 94 (02) : 116 - 121
  • [5] Rapid Identification and Antimicrobial Susceptibility Testing Directly from Blood Cultures of Gram-negative and Gram-positive Isolates
    Kong, Haishen
    Zhang, Shujin
    Chen, Xiao
    Zhang, Weili
    Yang, Qing
    Fu, Yajie
    Wang, Yiyin
    Li, Xuefen
    CLINICAL LABORATORY, 2013, 59 (11-12) : 1305 - 1310
  • [6] Saponin promotes rapid identification and antimicrobial susceptibility profiling of Gram-positive and Gram-negative bacteria in blood cultures with the Vitek 2 system
    Lupetti, A.
    Barnini, S.
    Morici, P.
    Ghelardi, E.
    Nibbering, P. H.
    Campa, M.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2013, 32 (04) : 493 - 502
  • [7] Saponin promotes rapid identification and antimicrobial susceptibility profiling of Gram-positive and Gram-negative bacteria in blood cultures with the Vitek 2 system
    A. Lupetti
    S. Barnini
    P. Morici
    E. Ghelardi
    P. H. Nibbering
    M. Campa
    European Journal of Clinical Microbiology & Infectious Diseases, 2013, 32 : 493 - 502
  • [8] Rapid direct identification and susceptibility testing of gram-negative rods from positive blood cultures by VITEK 2 in common practice
    Matten, J.
    Scharmann, C.
    Schwarz, R.
    INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2008, 298 : 6 - 7
  • [9] Evaluation of the Accelerate Pheno System for Fast Identification and Antimicrobial Susceptibility Testing from Positive Blood Cultures in Bloodstream Infections Caused by Gram-Negative Pathogens
    Marschal, Matthias
    Bachmaier, Johanna
    Autenrieth, Ingo
    Oberhettinger, Philipp
    Willmann, Matthias
    Peter, Silke
    JOURNAL OF CLINICAL MICROBIOLOGY, 2017, 55 (07) : 2116 - 2126
  • [10] Evaluation of the Merlin MICRONAUT system for rapid direct susceptibility testing of Gram-positive cocci and Gram-negative bacilli from positive blood cultures
    Wellinghausen, N.
    Pietzcker, T.
    Poppert, S.
    Belak, S.
    Fieser, N.
    Bartel, M.
    Essig, A.
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2007, 29 : S62 - S63