Evaluation of the Vitek® Reveal™ system for rapid antimicrobial susceptibility testing of Gram-negative pathogens, including ESBL, CRE and CRAB, from positive blood cultures

被引:1
|
作者
Antonelli, Alberto [1 ,2 ,3 ]
Cuffari, Sara [1 ,2 ]
Casciato, Benedetta [1 ,2 ]
Giani, Tommaso [1 ,2 ,3 ]
Rossolini, Gian Maria [1 ,2 ,3 ]
机构
[1] Univ Florence, Dept Expt & Clin Med, Florence, Italy
[2] Careggi Univ Hosp, Microbiol & Virol Unit, Florence, Italy
[3] Univ Florence, IRCCS Don Gnocchi Fdn, NARR Joint Lab Antimicrobial Resistance Res & Cont, Florence, Italy
关键词
Rapid AST; CRE; CRAB; Bloodstream infections; KLEBSIELLA-PNEUMONIAE; IDENTIFICATION; TIME;
D O I
10.1016/j.diagmicrobio.2024.116503
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Blood culture (BC) remains the reference diagnostic tool for bloodstream infections but is hampered by long turnaround time (TAT). This study evaluated the Vitek (R) RevealTM (VR) system for rapid antimicrobial susceptibility testing (AST) with 72 cases of monomicrobial BCs (55 Enterobacterales, 12 Pseudomonas aeruginosa and 5 Acinetobacter baumannii), including isolates producing carbapenemases and/or extended-spectrum beta-lactamases. VR returned AST results with a mean TAT of 5.4 h. Compared to a conventional workflow based on broth microdilution, VR exhibited essential agreement (EA) and category agreement (CA) >90 % in most cases, except with meropenem for Enterobacterales (CA, 85.5 %), piperacillin/tazobactam for P. aeruginosa (EA, 83.3 %), and trimethoprim/sulfamethoxazole for A. baumannii (CA and EA, 80 %). Bias exhibited an underestimation trend with ceftazidime/avibactam (-78.9 %) and ceftazidime (-50 %) for Enterobacterales and P. aeruginosa, respectively. Overall, VR appears an interesting tool to decrease TAT of the BC workflow, although further evaluation with some antibiotic-pathogen combinations would be warranted.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Accuracy of the VITEK® 2 system for a rapid and direct identification and susceptibility testing of Gram-negative rods and Gram-positive cocci in blood samples
    Nimer, N. A.
    Al-Saa'da, R. J.
    Abuelaish, O.
    EASTERN MEDITERRANEAN HEALTH JOURNAL, 2016, 22 (03) : 193 - 200
  • [22] Evaluation of VITEK 2 rapid identification and susceptibility testing system against Gram-negative clinical isolates
    Ling, TKW
    Tam, PC
    Liu, ZK
    Cheng, AFB
    JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (08) : 2964 - 2966
  • [23] Direct inoculation of positive blood cultures using the Phoenix system for antimicrobial susceptibility testing of both Gram-positive and Gram-negative bacteria
    Florio, Walter
    Barnini, Simona
    Morici, Paola
    Lupetti, Antonella
    JOURNAL OF MEDICAL MICROBIOLOGY, 2015, 64 : 582 - 585
  • [24] Rapid identification and antimicrobial susceptibility profiling of Gram-positive cocci in blood cultures with the Vitek 2 system
    Lupetti, A.
    Barnini, S.
    Castagna, B.
    Capria, A. -L.
    Nibbering, P. H.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2010, 29 (01) : 89 - 95
  • [25] Rapid identification and antimicrobial susceptibility profiling of Gram-positive cocci in blood cultures with the Vitek 2 system
    A. Lupetti
    S. Barnini
    B. Castagna
    A.-L. Capria
    P. H. Nibbering
    European Journal of Clinical Microbiology & Infectious Diseases, 2010, 29 : 89 - 95
  • [26] Performance of a System for Rapid Phenotypic Antimicrobial Susceptibility Testing of Gram-Negative Bacteria Directly from Positive Blood Culture Bottles
    Goransson, J.
    Sundqvist, M.
    Ghaderi, E.
    Lisby, J. G.
    Molin, Y.
    Eriksson, E.
    Carlsson, S.
    Cederlof, A.
    Ellis, L.
    Melin, J.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2023, 61 (03) : e0152522
  • [27] Evaluation of antimicrobial susceptibility testing directly from positive blood cultures using the Vitek 2 system: comparison of two rapid protocols
    Porte, Lorena
    Gattini, Francesca
    Varela, Carmen
    Weitzel, Thomas
    REVISTA CHILENA DE INFECTOLOGIA, 2017, 34 (02): : 190 - +
  • [28] Evaluation of the VITEK® 2 system for testing of Gram-negative bacilli directly from BacT/Alert Fan blood cultures
    Ullberg, M.
    Bergstrom, J.
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2007, 29 : S487 - S487
  • [29] Rapid phenotypic antimicrobial susceptibility testing of Gram-negative rods directly from positive blood cultures using the novel Q-linea ASTar system
    Esse, Jan
    Traeger, Johannes
    Valenza, Giuseppe
    Bogdan, Christian
    Held, Juergen
    JOURNAL OF CLINICAL MICROBIOLOGY, 2023, 61 (11)
  • [30] EVALUATION OF THE COBAS-BACT SYSTEM FOR DIRECT AND RAPID IDENTIFICATION AND ANTIMICROBIAL SUSCEPTIBILITY TESTING OF GRAM-NEGATIVE RODS FROM POSITIVE BLOOD CULTURE BROTHS
    KAMM, W
    WENGER, A
    BILLE, J
    JOURNAL OF CLINICAL MICROBIOLOGY, 1989, 27 (01) : 102 - 105