Evaluation of robotic-assisted navigation system for CT-guided thoracic and abdominal lesion puncture: A prospective clinical study

被引:1
|
作者
Jing, Yifan [1 ]
Zhang, Jian [1 ]
Jin, Yong [1 ]
Bai, Xuming [1 ]
机构
[1] Soochow Univ, Affiliated Hosp 2, Dept Intervent Radiol, Suzhou, Jiangsu, Peoples R China
关键词
Accuracy; computer tomography; percutaneous needle insertion; robotic-assisted navigation system; safety; TRANSTHORACIC NEEDLE-BIOPSY; MICROWAVE ABLATION; LIVER-TUMORS; COMPLICATIONS;
D O I
10.4103/jcrt.jcrt_373_24
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: The study aims to compare the accuracy and safety of robotic-assisted navigation puncture to freehand puncture during computed tomography (CT)-guided percutaneous needle insertion in the chest and abdomen. Methods: A total of 60 patients required percutaneous puncture procedures, with 40 involving the chest and 20 involving the abdomen. Eligible patients were randomly assigned to two groups. The test group punctured using a robotic-assisted navigation system, whereas the control group punctured manually. The primary outcome assessment standards are single puncture success rates, with the number of needle modifications and CT scan timings during the procedure serving as supplementary outcome evaluation standards. The Wilcoxon rank sum test is used for the comparison. Results: The puncture procedure's success rates after just one puncture: The test group punctures accurately without adjusting the puncture needle, while the control group uses an average number of 1.73 +/- 1.20 pins. The once-puncture success rate of robot navigation puncture is considerably higher than that of bare-handed puncture (P < 0.001). The times of CT scan are necessitated when the puncture is in place: the average times in the test group is 3.03 +/- 0.18 times, while the control group is 4.70 +/- 1.24 times. Conclusion: In conclusion, the robotic-assisted navigation system improves puncture accuracy while reducing the need for needle corrections during percutaneous puncture procedures. It also shortens CT scans and reduces radiation exposure from X-rays.
引用
收藏
页码:1350 / 1356
页数:7
相关论文
共 50 条
  • [1] Phantom evaluation of a navigation system for out-of-plane CT-guided puncture
    Moncharmont, L.
    Moreau-Gaudry, A.
    Medici, M.
    Bricault, I.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2015, 96 (06) : 531 - 536
  • [2] Robotic-assisted CT-guided percutaneous thermal ablation of abdominal tumors: An analysis of 41 patients
    Bonnet, Baptiste
    de Baere, Thierry
    Beunon, Paul
    Feddal, Adlane
    Tselikas, Lambros
    Deschamps, Frederic
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (06) : 227 - 232
  • [3] Clinical evaluation of a robotic system for precise CT-guided percutaneous procedures
    Levy, Shiran
    Goldberg, S. Nahum
    Roth, Ido
    Shochat, Moran
    Sosna, Jacob
    Leichter, Isaac
    Flacke, Sebastian
    ABDOMINAL RADIOLOGY, 2021, 46 (10) : 5007 - 5016
  • [4] Clinical evaluation of a robotic system for precise CT-guided percutaneous procedures
    Shiran Levy
    S. Nahum Goldberg
    Ido Roth
    Moran Shochat
    Jacob Sosna
    Isaac Leichter
    Sebastian Flacke
    Abdominal Radiology, 2021, 46 : 5007 - 5016
  • [5] Feasibility of image-guided navigation during robotic-assisted surgery: A prospective study
    Aguilera Saiz, L.
    Heerink, W. J.
    Groen, H. C.
    Hiep, M. A. J.
    Van Der Poel, H. G.
    Wit, E. M. K.
    Nieuwenhuijzen, J. A.
    Roeleveld, T. A.
    Van Leeuwen, P. J.
    Ruers, T. J. M.
    EUROPEAN UROLOGY, 2024, 85 : S560 - S560
  • [6] Robotic-assisted versus manual Uro-Dyna CT-guided puncture in an ex-vivo kidney model
    Grune, B.
    Burger, R.
    Bauer, D.
    Schaefer, A.
    Rothfuss, A.
    Stallkamp, J.
    Kriegmair, M. C.
    Rassweiler-Seyfried, M-C
    EUROPEAN UROLOGY, 2022, 81 : S1495 - S1495
  • [7] Ultrasonographic guided Robotic-assisted percutaneous renal puncture: A feasibility study
    Piro, A.
    Eissa, A.
    Resca, S.
    Vella, J.
    Ientile, R.
    de Faveri, A.
    Di Bari, S.
    Ferraguti, F.
    Bazzani, S.
    Secchi, C.
    Ferretti, S.
    Puliatti, S.
    Micali, S.
    Bianchi, G.
    EUROPEAN UROLOGY, 2024, 85 : S2046 - S2047
  • [8] Augmented Reality-Assisted CT-Guided Puncture: A Phantom Study
    Vincent Van den Bosch
    Hizirwan Shukri Salim
    Njin-Zu Chen
    Otto Stroosma
    Philipp Bruners
    Christiane K. Kuhl
    Federico Pedersoli
    Peter Isfort
    CardioVascular and Interventional Radiology, 2022, 45 : 1173 - 1177
  • [9] Augmented Reality-Assisted CT-Guided Puncture: A Phantom Study
    Van den Bosch, Vincent
    Salim, Hizirwan Shukri
    Chen, Njin-Zu
    Stroosma, Otto
    Bruners, Philipp
    Kuhl, Christiane K.
    Pedersoli, Federico
    Isfort, Peter
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 45 (08) : 1173 - 1177
  • [10] Robotic-assisted bronchoscopy versus CT-guided transthoracic biopsy for diagnosis of pulmonary nodules
    Lee-Mateus, Alejandra Yu
    Reisenauer, Janani
    Garcia-Saucedo, Juan C.
    Abia-Trujillo, David
    Buckarma, EeeLN H.
    Edell, Eric S.
    Grage, Rolf A.
    Bowman, Andrew W.
    Labarca, Gonzalo
    Johnson, Margaret M.
    Patel, Neal M.
    Fernandez-Bussy, Sebastian
    RESPIROLOGY, 2023, 28 (01) : 66 - 73