Evaluation of robotic-assisted navigation system for CT-guided thoracic and abdominal lesion puncture: A prospective clinical study

被引:1
|
作者
Jing, Yifan [1 ]
Zhang, Jian [1 ]
Jin, Yong [1 ]
Bai, Xuming [1 ]
机构
[1] Soochow Univ, Affiliated Hosp 2, Dept Intervent Radiol, Suzhou, Jiangsu, Peoples R China
关键词
Accuracy; computer tomography; percutaneous needle insertion; robotic-assisted navigation system; safety; TRANSTHORACIC NEEDLE-BIOPSY; MICROWAVE ABLATION; LIVER-TUMORS; COMPLICATIONS;
D O I
10.4103/jcrt.jcrt_373_24
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: The study aims to compare the accuracy and safety of robotic-assisted navigation puncture to freehand puncture during computed tomography (CT)-guided percutaneous needle insertion in the chest and abdomen. Methods: A total of 60 patients required percutaneous puncture procedures, with 40 involving the chest and 20 involving the abdomen. Eligible patients were randomly assigned to two groups. The test group punctured using a robotic-assisted navigation system, whereas the control group punctured manually. The primary outcome assessment standards are single puncture success rates, with the number of needle modifications and CT scan timings during the procedure serving as supplementary outcome evaluation standards. The Wilcoxon rank sum test is used for the comparison. Results: The puncture procedure's success rates after just one puncture: The test group punctures accurately without adjusting the puncture needle, while the control group uses an average number of 1.73 +/- 1.20 pins. The once-puncture success rate of robot navigation puncture is considerably higher than that of bare-handed puncture (P < 0.001). The times of CT scan are necessitated when the puncture is in place: the average times in the test group is 3.03 +/- 0.18 times, while the control group is 4.70 +/- 1.24 times. Conclusion: In conclusion, the robotic-assisted navigation system improves puncture accuracy while reducing the need for needle corrections during percutaneous puncture procedures. It also shortens CT scans and reduces radiation exposure from X-rays.
引用
收藏
页码:1350 / 1356
页数:7
相关论文
共 50 条
  • [31] Clinical Observation of CT-Guided Intervertebral Foramen Puncture and Radiofrequency Thermocoagulation for the Treatment of Refractory PHN in the Superior Thoracic Segment
    Du, Xindan
    Zhao, Wensheng
    Xu, Lulu
    Zhang, Tieshan
    Li, Langping
    Huang, Bing
    PAIN PHYSICIAN, 2022, 25 (05) : E767 - E775
  • [32] Robotic-assisted navigation system for preoperative percutaneous lung nodule localization: A pilot study
    Lin, Y.
    JOURNAL OF THORACIC ONCOLOGY, 2023, 18 (04) : S156 - S156
  • [33] Robotic-Assisted Inguinal Hernia Repair with The Dexter System™: A Prospective Multicentre Clinical Investigation
    Gantner, L.
    Mignot, H.
    Pochhammer, J.
    Grieder, F.
    Breitenstein, S.
    BRITISH JOURNAL OF SURGERY, 2024, 111
  • [34] CT-GUIDED PERCUTANEOUS ASPIRATION AND DRAINAGE OF ABDOMINAL ABSCESSES - PROSPECTIVE-STUDY OF 63 CASES
    DONDELINGER, RF
    DEBAETS, P
    KURDZIEL, JC
    ANNALES DE RADIOLOGIE, 1987, 30 (06) : 373 - 385
  • [35] A novel Laser Navigation System reduces radiation exposure and improves accuracy and workflow of CT-guided spinal interventions: A prospective, randomized, controlled, clinical trial in comparison to conventional freehand puncture
    Moser, Carsten
    Becker, Jan
    Deli, Martin
    Busch, Martin
    Boehme, Marc
    Groenemeyer, Dietrich H. W.
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (04) : 627 - 632
  • [36] Clinical application of optical and electromagnetic navigation system in CT-guided radiofrequency ablation of lung metastases
    Chen, Zenan
    Meng, Liangliang
    Xiao, Yueyong
    Zhang, Jing
    Zhang, Xiaobo
    Wei, Yingtian
    He, Xiaofeng
    Zhang, Xin
    Zhang, Xiao
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2024, 41 (01)
  • [37] Evaluation of a Robotic Assistance-System For Percutaneous Computed Tomography-Guided (CT-Guided) Facet Joint Injection: A Phantom Study
    Beyer, Lukas Philipp
    Michalik, Katharina
    Niessen, Christoph
    da Silva, Natascha Platz Batista
    Wiesinger, Isabell
    Stroszczynski, Christian
    Wiggermann, Philipp
    MEDICAL SCIENCE MONITOR, 2016, 22 : 3334 - 3339
  • [38] Gyroscope-Assisted CT-Guided Puncture Improves Accuracy and Hit Rate Compared with Free-Hand Puncture: A Phantom Study
    Saeed, Saher
    Niehoff, Julius Henning
    Boriesosdick, Jan
    Michael, Arwed
    Schoenbeck, Denise
    Woeltjen, Matthias Michael
    Haag, Nina P.
    Moenninghoff, Christoph
    Borggrefe, Jan
    Kroeger, Jan Robert
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2024, 47 (12) : 1786 - 1794
  • [39] Evaluation of the clinical benefit of an electromagnetic navigation system for CT-guided interventional radiology procedures in the thoraco-abdominal region compared with conventional CT guidance (CTNAV II): study protocol for a randomised controlled trial
    Rouchy, R. C.
    Moreau-Gaudry, A.
    Chipon, E.
    Aubry, S.
    Pazart, L.
    Lapuyade, B.
    Durand, M.
    Hajjam, M.
    Pottier, S.
    Renard, B.
    Logier, R.
    Orry, X.
    Cherifi, A.
    Quehen, E.
    Kervio, G.
    Favelle, O.
    Patat, F.
    De Kerviler, E.
    Hughes, C.
    Medici, M.
    Ghelfi, J.
    Mounier, A.
    Bricault, I.
    TRIALS, 2017, 18
  • [40] Clinical evaluation of autonomous robotic-assisted full-arch implant surgery: A 1-year prospective clinical study
    Xie, Rui
    Liu, Yuchen
    Wei, Hongbo
    Zhang, Tingmin
    Bai, Shizhu
    Zhao, Yimin
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (04) : 443 - 453