Test-Retest Reliability of an Isometric and Isometric/Vibratory Muscular Strength Protocol with Functional Electro-Mechanical Dynamometry

被引:2
|
作者
Andrades-Ramirez, Oscar [1 ]
Ulloa-Diaz, David [2 ]
Alfaro Castillo, Bryan [3 ]
Arroyo-Jofre, Patricio [4 ]
Castillo-Paredes, Antonio [5 ]
Chirosa-Rios, Luis [6 ]
机构
[1] Univ las Americas, Escuela Ciencias Act Fis, Fac Salud & Ciencias Sociales, Concepcion 4030000, Chile
[2] Univ Catolica Santisima Concepcion, Dept Sports Sci & Phys Conditioning, Concepcion 4030000, Chile
[3] Univ Atacama, Fac Educ, Copiapo 1531772, Chile
[4] Univ San Sebastian, Fac Educ, Santiago 8420524, Chile
[5] Univ las Americas, Escuela Pedag Educ Fis, Fac Educ, Grp AFySE,Invest Actividad Fis & Salud Escolar, Santiago 8370040, Chile
[6] Univ Granada, Fac Sport Sci, Dept Phys Educ & Sport, Granada 18011, Spain
关键词
muscular strength; reliability; dynamometer; isokinetic; MUSCLE STRENGTH; VARIABLES;
D O I
10.3390/sports12070175
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The purpose of the study was to analyze the test-retest reliability of an isometric and isometric/vibratory muscular strength protocol in the bilateral seated bench press (BSBP), bilateral seated rowing (BSR), unilateral seated right knee extension (USKER), and left knee extension (USKEL) tests controlled using functional electromechanical dynamometry (FEMD) in healthy young adults. A repeated measures design was used to determine the reliability of a muscular strength protocol in isometric and isometric vibration modes with FEMD. No significant differences were found in test-retest analysis (p > 0.05; ES < 0.20); and high reliability (CV = 4.65-5.02%; ICC = 0.99-0.98) was found for BSBP measures, and acceptable reliability (CV = 3.71-9.61%; ICC = 0.98-0.95) was found for BSR, USKER, and USKEL. Furthermore, the coefficients between the two measures were strong (r = 0.963-0.839) and highly significant (p = 0.001) for maximal strength in the isometric and maximal isometric/vibratory assessment of muscle strength in all muscle strength tests. This study demonstrates that isometric and maximal isometric/vibratory strength in the BSBP, BSR, USKER, and USKEL tests can be measured with high reliability and reproducibility using the FEMD.
引用
收藏
页数:12
相关论文
共 48 条
  • [31] AGE-RELATED TEST-RETEST RELIABILITY OF ISOMETRIC TRUNK TORQUE MEASUREMENTS IN PATIENTS WITH CHRONIC LOW BACK PAIN
    Kienbacher, Thomas
    Kollmitzer, Josef
    Anders, Philipp
    Habenicht, Richard
    Starek, Christian
    Wolf, Markus
    Paul, Birgit
    Mair, Patrick
    Ebenbichler, Gerold
    JOURNAL OF REHABILITATION MEDICINE, 2016, 48 (10) : 893 - 902
  • [32] A portable isometric knee extensor strength testing device: test-retest reliability and minimal detectable change scores of the Q-Force ӀӀ in healthy adults
    Johanneke Hartog
    Sandra Dijkstra
    Joke Fleer
    Pim van der Harst
    Massimo A. Mariani
    Lucas H. V. van der Woude
    BMC Musculoskeletal Disorders, 22
  • [33] Functional strength measurement in cerebral palsy: feasibility, test-retest reliability, and construct validity
    Aertssen, Wendy
    Smulders, Ellen
    Smits-Engelsman, Bouwien
    Rameckers, Eugene
    DEVELOPMENTAL NEUROREHABILITATION, 2019, 22 (07) : 453 - 461
  • [34] Investigating the Test-Retest Reliability and Validity of Hand-Held Dynamometry for Measuring Knee Strength in Older Women with Knee Osteoarthritis
    Chopp-Hurley, Jaclyn N.
    Wiebenga, Emily G.
    Gatti, Anthony A.
    Maly, Monica R.
    PHYSIOTHERAPY CANADA, 2019, 71 (03) : 231 - 238
  • [35] A portable isometric knee extensor strength testing device: test-retest reliability and minimal detectable change scores of the Q-Force II in healthy adults
    Hartog, Johanneke
    Dijkstra, Sandra
    Fleer, Joke
    van der Harst, Pim
    Mariani, Massimo A.
    van der Woude, Lucas H., V
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [36] Test-Retest Reliability of Isometric Leg Muscle Strength Measurements Made Using a Hand-Held Dynamometer Restrained by a Belt: Comparisons during and between Sessions
    Katoh, Munenori
    Yamasaki, Hiroshi
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2009, 21 (03) : 239 - 243
  • [37] Peak torque, rate of torque development and average torque of isometric ankle and elbow contractions show excellent test-retest reliability
    Simpson, Daniel
    Ehrensberger, Monika
    Nulty, Christopher
    Regan, Joanne
    Broderick, Patrick
    Blake, Catherine
    Monaghan, Kenneth
    HONG KONG PHYSIOTHERAPY JOURNAL, 2019, 39 (01) : 67 - 76
  • [38] Test-Retest Reliability and Concurrent Validity of FysioMeter C-Station Assessing Lower-Limb Muscle Strength via Isometric Mid-Thigh Pulls
    Sakstrup, Mathias G.
    Schmidt, Andreas
    O'Neill, Seth
    Green, Brady
    Jorgensen, Martin G.
    Stevenson, Andrew J. T.
    APPLIED SCIENCES-BASEL, 2025, 15 (03):
  • [39] A Specific Test of Starting Blocks: Intrasession and Intersession Reliability of Isometric Strength Using a Functional Electromechanical Dynamometer
    Mula-Perez, Francisco
    Manzano-Sanchez, David
    Chirosa-Rios, Luis J.
    Chirosa-Rios, Ignacio J.
    Rodriguez-Perea, Angela
    APPLIED SCIENCES-BASEL, 2024, 14 (17):
  • [40] Test-retest reliability of the functional reach test and the hand grip strength test in older adults using nursing home services
    Ferreira, Soraia
    Raimundo, Armando
    Marmeleira, Jose
    IRISH JOURNAL OF MEDICAL SCIENCE, 2021, 190 (04) : 1625 - 1632