Test-Retest Reliability of an Isometric and Isometric/Vibratory Muscular Strength Protocol with Functional Electro-Mechanical Dynamometry

被引:2
|
作者
Andrades-Ramirez, Oscar [1 ]
Ulloa-Diaz, David [2 ]
Alfaro Castillo, Bryan [3 ]
Arroyo-Jofre, Patricio [4 ]
Castillo-Paredes, Antonio [5 ]
Chirosa-Rios, Luis [6 ]
机构
[1] Univ las Americas, Escuela Ciencias Act Fis, Fac Salud & Ciencias Sociales, Concepcion 4030000, Chile
[2] Univ Catolica Santisima Concepcion, Dept Sports Sci & Phys Conditioning, Concepcion 4030000, Chile
[3] Univ Atacama, Fac Educ, Copiapo 1531772, Chile
[4] Univ San Sebastian, Fac Educ, Santiago 8420524, Chile
[5] Univ las Americas, Escuela Pedag Educ Fis, Fac Educ, Grp AFySE,Invest Actividad Fis & Salud Escolar, Santiago 8370040, Chile
[6] Univ Granada, Fac Sport Sci, Dept Phys Educ & Sport, Granada 18011, Spain
关键词
muscular strength; reliability; dynamometer; isokinetic; MUSCLE STRENGTH; VARIABLES;
D O I
10.3390/sports12070175
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The purpose of the study was to analyze the test-retest reliability of an isometric and isometric/vibratory muscular strength protocol in the bilateral seated bench press (BSBP), bilateral seated rowing (BSR), unilateral seated right knee extension (USKER), and left knee extension (USKEL) tests controlled using functional electromechanical dynamometry (FEMD) in healthy young adults. A repeated measures design was used to determine the reliability of a muscular strength protocol in isometric and isometric vibration modes with FEMD. No significant differences were found in test-retest analysis (p > 0.05; ES < 0.20); and high reliability (CV = 4.65-5.02%; ICC = 0.99-0.98) was found for BSBP measures, and acceptable reliability (CV = 3.71-9.61%; ICC = 0.98-0.95) was found for BSR, USKER, and USKEL. Furthermore, the coefficients between the two measures were strong (r = 0.963-0.839) and highly significant (p = 0.001) for maximal strength in the isometric and maximal isometric/vibratory assessment of muscle strength in all muscle strength tests. This study demonstrates that isometric and maximal isometric/vibratory strength in the BSBP, BSR, USKER, and USKEL tests can be measured with high reliability and reproducibility using the FEMD.
引用
收藏
页数:12
相关论文
共 48 条
  • [21] Test-Retest Reliability of Biodex System 4 Pro for Isometric Ankle-Eversion and -Inversion Measurement
    Tankevicius, Gediminas
    Lankaite, Donata
    Krisciunas, Aleksandras
    JOURNAL OF SPORT REHABILITATION, 2013, 22 (03) : 212 - 215
  • [22] Test-retest strength reliability: Hand-held dynamometry in community-dwelling elderly fallers
    Wang, CY
    Olson, SL
    Protas, EJ
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (06): : 811 - 815
  • [23] Effect of Knee and Trunk Angle on Kinetic Variables During the Isometric Midthigh Pull: Test-Retest Reliability
    Comfort, Paul
    Jones, Paul A.
    McMahon, John J.
    Newton, Robert
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2015, 10 (01) : 58 - 63
  • [24] Test-Retest Reliability of Concentric and Eccentric Muscle Strength in Knee Flexion-Extension Controlled by Functional Electromechanical Dynamometry in female Soccer
    Andrades-Ramirez, Oscar
    Ulloa-Diaz, David
    Rodriguez-Perea, Angela
    Araya-Sierralta, Sergio
    Guede-Rojas, Francisco
    Munoz-Bustos, Gustavo
    Chirosa-Rios, Luis-Javier
    APPLIED SCIENCES-BASEL, 2024, 14 (19):
  • [25] Test-retest reliability of TMS motor evoked responses and silent periods during explosive voluntary isometric contractions
    Castelli, F.
    Mian, O. S.
    Bruton, A.
    Valappil, A. C.
    Tillin, N. A.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2025,
  • [26] ISOMETRIC QUADRICEPS STRENGTH TEST DEVICE TO IMPROVE THE RELIABILITY OF HANDHELD DYNAMOMETRY IN PATIENT WITH ANTERIOR CRUCIATE LIGAMENT INJURY
    McNamara, Stephanie
    Hevia, Elizabeth Gallardo
    St Louis, Reggie
    Cho, William
    Lee, Sangjun
    Moyne, Martina
    Quinlivan, Brendan
    Payne, Christopher J.
    Walsh, Conor
    Schiller, Greg
    Awad, Louis N.
    2018 DESIGN OF MEDICAL DEVICES CONFERENCE, 2018,
  • [27] Test-Retest Reliability of Isometric and Isokinetic Knee Extension and Flexion in Patients With Fibromyalgia: Evaluation of the Smallest Real Difference
    Adsuar, Jose C.
    Olivares, Pedro R.
    del Pozo-Cruz, Borja
    Parraca, Jose A.
    Gusi, Narcis
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2011, 92 (10): : 1646 - 1651
  • [28] Test-retest reliability of muscle fiber conduction velocity and fractal dimension of surface EMG during isometric contractions
    Beretta-Piccoli, Matteo
    D'Antona, Giuseppe
    Zampella, Cristian
    Barbero, Marco
    Clijsen, Ron
    Cescon, Corrado
    PHYSIOLOGICAL MEASUREMENT, 2017, 38 (04) : 616 - 630
  • [29] Reliability of Isometric Knee Extension Muscle Strength Measurement Using a Hand-held Dynamometer with a Belt: A Study of Test-retest Reliability in Healthy Elderly Subjects
    Katoh, Munenori
    Isozaki, Koji
    Sakanoue, Noboru
    Miyahara, Takuya
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2010, 22 (04) : 359 - 363
  • [30] Test-retest Reliability of Isometric Knee Extension Muscle Strength Measurement using a Hand-held Dynamometer and a Belt: Study of Hemiplegic Patients
    Katoh, Munenori
    Asuma, Hitomi
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2011, 23 (01) : 25 - 28