Delayed-Onset Orbital Abscess After Orbital Blowout Fracture Repair Using Porous Polyethylene Implant

被引:0
|
作者
Han, Kwang Eon [1 ,2 ]
Ahn, Jung Hyo [1 ,2 ]
机构
[1] Pusan Natl Univ, Yangsan Hosp, Sch Med, Dept Ophthalmol, 20 Geu mo ro,Mulgum, Yangsan 50612, Gyeongnam, South Korea
[2] Pusan Natl Univ, Yangsan Hosp, Sch Med, Res Inst Convergence Biomed Sci & Technol, Yangsan, South Korea
关键词
Orbital abscess; orbital implant; orbital wall fracture repair; porous polyethylene implant; COMPLICATIONS; CELLULITIS; FLOOR;
D O I
10.1097/SCS.0000000000010435
中图分类号
R61 [外科手术学];
学科分类号
摘要
This study aims at documenting a rare case of delayed-onset orbital abscess following the use of a nonabsorbable porous polyethylene implant in orbital fracture repair, highlighting the potential long-term risks associated with non-biodegradable orbital implants. A 44-year-old man presented with diplopia on down gaze, proptosis, and eyelid edema for 2 weeks. He had undergone repair of an inferior orbital wall fracture with a porous polyethylene implant 5 years ago. Computed tomography (CT) evaluation revealed a significant intraorbital abscess related to implant infection. Surgical interventions included abscess drainage and implant replacement, which led to patient recovery. Nonabsorbable implants, which are beneficial for orbital reconstruction, may pose a risk of occurrence of delayed infections several years following surgery. This report highlights the importance of long-term monitoring to mitigate the risks of potential late complications, which necessitate early diagnosis, appropriate intervention, and management strategies.
引用
收藏
页码:e588 / e590
页数:3
相关论文
共 50 条
  • [41] Analysis of the effect of repair materials for orbital blowout fracture on complications
    Qi-Hua Xu
    Jin-Hai Yu
    Yao-Hua Wang
    An-An Wang
    Hong-Fei Liao
    International Journal of Ophthalmology, 2019, (11) : 1746 - 1750
  • [42] Acute traumatic orbital encephalocele related to orbital roof fracture:: reconstruction by using porous polyethylene
    Gaziolu, Nurperi
    Ulu, Mustafa Onur
    Ozlen, Fatma
    Uzan, Mustafa
    Ciplak, Nejat
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2008, 14 (03): : 247 - 252
  • [43] Prognostic CT findings of diplopia after surgical repair of pure orbital blowout fracture
    Jung, Hyena
    Byun, Jae Young
    Kim, Hyung-Jin
    Min, Ji Hye
    Park, Gyeong Min
    Kim, Ha Youn
    Kim, Yi Kyung
    Cha, Jihoon
    Kim, Sung Tae
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (09) : 1479 - 1484
  • [44] The quasi-integrated porous polyethylene orbital implant
    Anderson, RL
    Yen, MT
    Lucci, LM
    Caruso, RT
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2002, 18 (01): : 50 - 55
  • [45] Burnishing of exposed porous polyethylene orbital implant: is it useful?
    Lai, Kenneth K. H.
    Lam, Matthew C. W.
    Kelvin, K. L.
    Yuen, Hunter K. L.
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2024, 59 (03): : e239 - e244
  • [46] Results of Porous Polyethylene Sphere as an Anopthalmic Orbital Implant
    Banaz, Akin
    Aydin, Onur
    Arslan, M. Okan
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2005, 35 (04): : 346 - 351
  • [47] Extrusion of porous polyethylene orbital implant in recurrent retinoblastoma
    Karcioglu, ZA
    Mullaney, PB
    Millar, LC
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 14 (01): : 37 - 44
  • [48] Porous polyethylene orbital implant in the pediatric population.
    Iordanidou, V
    De Potter, P
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 138 (03) : 425 - 429
  • [49] Pneumo-orbital cyst after orbital fracture repair
    Neves, RB
    Yeatts, RP
    Martin, TJ
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 125 (06) : 879 - 880
  • [50] Orbital floor repair using medpor porous polyethylene implants.
    Lupi, E
    Messi, M
    Ascani, G
    Balercia, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U504 - U504