Delayed-Onset Orbital Abscess After Orbital Blowout Fracture Repair Using Porous Polyethylene Implant

被引:0
|
作者
Han, Kwang Eon [1 ,2 ]
Ahn, Jung Hyo [1 ,2 ]
机构
[1] Pusan Natl Univ, Yangsan Hosp, Sch Med, Dept Ophthalmol, 20 Geu mo ro,Mulgum, Yangsan 50612, Gyeongnam, South Korea
[2] Pusan Natl Univ, Yangsan Hosp, Sch Med, Res Inst Convergence Biomed Sci & Technol, Yangsan, South Korea
关键词
Orbital abscess; orbital implant; orbital wall fracture repair; porous polyethylene implant; COMPLICATIONS; CELLULITIS; FLOOR;
D O I
10.1097/SCS.0000000000010435
中图分类号
R61 [外科手术学];
学科分类号
摘要
This study aims at documenting a rare case of delayed-onset orbital abscess following the use of a nonabsorbable porous polyethylene implant in orbital fracture repair, highlighting the potential long-term risks associated with non-biodegradable orbital implants. A 44-year-old man presented with diplopia on down gaze, proptosis, and eyelid edema for 2 weeks. He had undergone repair of an inferior orbital wall fracture with a porous polyethylene implant 5 years ago. Computed tomography (CT) evaluation revealed a significant intraorbital abscess related to implant infection. Surgical interventions included abscess drainage and implant replacement, which led to patient recovery. Nonabsorbable implants, which are beneficial for orbital reconstruction, may pose a risk of occurrence of delayed infections several years following surgery. This report highlights the importance of long-term monitoring to mitigate the risks of potential late complications, which necessitate early diagnosis, appropriate intervention, and management strategies.
引用
收藏
页码:e588 / e590
页数:3
相关论文
共 50 条
  • [21] Orbital cellulitis: A rare complication after orbital blowout fracture
    Ben Simon, GJ
    Bush, S
    Selva, D
    McNab, AA
    OPHTHALMOLOGY, 2005, 112 (11) : 2030 - 2034
  • [22] Drilling of a porous polyethylene orbital implant
    Uyemura, MJ
    Farris, SR
    Popham, JK
    Damiano, T
    Sandberg, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 2854 - 2854
  • [23] An infected porous polyethylene orbital implant
    Jordan, David R.
    Brownstein, Seymour
    Rawlings, Nigel
    Robinson, Jennifer
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2007, 23 (05): : 413 - 415
  • [24] Re: warfarin-associated delayed orbital haemorrhage after orbital fracture repair with smooth nylon foil implant
    McNab, Alan A.
    ORBIT-THE INTERNATIONAL JOURNAL ON ORBITAL DISORDERS-OCULOPLASTIC AND LACRIMAL SURGERY, 2019, 38 (06): : 524 - 524
  • [25] Massive Orbital Abscess After Orbital Wall Fracture
    Chen, Darren A.
    Lin, Lisa Y.
    Yoon, Michael K.
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2024, 40 (06): : e246 - e246
  • [26] Repair of blowout orbital floor fracture by periosteal suturing
    Noda, Mika
    Noda, Kousuke
    Ideta, Shinji
    Nakamura, Yasuhisa
    Ishida, Susumu
    Inoue, Makoto
    Tsubota, Kazuo
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (04): : 364 - 369
  • [27] Reply Re: warfarin-associated delayed orbital haemorrhage after orbital fracture repair with smooth nylon foil implant
    Jaru-Ampornpan, Pimkwan
    Joseph, Shannon S.
    Grisolia, Ana Beatriz
    Briceno, Cesar
    ORBIT-THE INTERNATIONAL JOURNAL ON ORBITAL DISORDERS-OCULOPLASTIC AND LACRIMAL SURGERY, 2019, 38 (06): : 525 - 525
  • [28] Orbital Emphysema After Repair of Orbital Fracture
    Wang, Hang
    An, Jingang
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (07) : E687 - E688
  • [29] Comminuted orbital blowout fracture after vigorous nose blowing that required repair
    Rahmel, Benjamin B.
    Scott, Cameron R.
    Lynham, Anthony J.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2010, 48 (04): : E21 - E22
  • [30] Delayed Repair of Lateral Orbital Wall and Orbital Floor Fracture
    Lee, James
    Tahiri, Youssef
    Roy, Andree-Anne
    Lessard, Lucie
    JOURNAL OF CRANIOFACIAL SURGERY, 2013, 24 (01) : 34 - 37