The Effect of Relative Humidity in Conductive Atomic Force Microscopy

被引:0
|
作者
Yuan, Yue [1 ]
Lanza, Mario [1 ,2 ]
机构
[1] King Abdullah Univ Sci & Technol KAUST, Phys Sci & Engn Div, Mat Sci & Engn Program, Thuwal 23955, Saudi Arabia
[2] Natl Univ Singapore, Dept Mat Sci & Engn, Singapore 117575, Singapore
关键词
2D materials; conductive atomic force microscopy; metrology; nanoelectronics; relative humidity; OXIDES; SIO2-FILMS; VACUUM; THIN;
D O I
10.1002/adma.202405932
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Conductive atomic force microscopy (CAFM) analyzes electronic phenomena in materials and devices with nanoscale lateral resolution, and it is widely used by companies, research institutions, and universities. Most data published in the field of CAFM is collected in air at a relative humidity (RH) of 30-60%. However, the effect of RH in CAFM remains unclear because previous studies often made contradictory claims, plus the number of samples and locations tested is scarce. Moreover, previous studies on this topic did not apply current limitations, which can degrade the CAFM tips and generate false data. This article systematically analyzes the effect of RH in CAFM by applying ramped voltage stresses at over 17,000 locations on ten different samples (insulating, semiconducting, and conducting) under seven different RH. An ultra-reliable setup with a 110-pA current limitation during electrical stresses is employed, and excellent CAFM tip integrity after thousands of tests is demonstrated. It is found that higher RH results in increased currents due to the presence of a conductive water meniscus at the tip/sample junction, which increases the effective area for electron flow. This trend is observed in insulators and ultra-thin semiconductors; however, in thicker semiconductors the electron mean free path is high enough to mask this effect. Metallic samples show no dependence on RH. This study clarifies the effect of relative humidity in CAFM, enhances understanding of the technique, and teaches researchers how to improve the reliability of their studies in this field. In this article, the impact of relative humidity (RH) on conductive atomic force microscopy (CAFM) measurements is investigated. For insulating and ultra-thin (less than 5 nm) semiconducting samples, a RH at 4% results in lower and more inhomogeneous currents compared to RH = 54%. In contrast, for thicker semiconducting (above 5 nm) and metallic samples, RH has no significant effect. These observations are confirmed by over 17,000 tests at different locations of ten samples. image
引用
收藏
页数:15
相关论文
共 50 条
  • [41] EFFECTS OF HUMIDITY AND TIP RADIUS ON THE ADHESIVE FORCE MEASURED WITH ATOMIC-FORCE MICROSCOPY
    SUGAWARA, Y
    OHTA, M
    KONISHI, T
    MORITA, S
    SUZUKI, M
    ENOMOTO, Y
    WEAR, 1993, 168 (1-2) : 13 - 16
  • [42] Humidity effects on the determination of elastic properties by atomic force acoustic microscopy
    Hurley, DC
    Turner, JA
    JOURNAL OF APPLIED PHYSICS, 2004, 95 (05) : 2403 - 2407
  • [43] Relative microelastic mapping of living cells by atomic force microscopy
    A-Hassan, E
    Heinz, WF
    Antonik, MD
    D'Costa, NP
    Nageswaran, S
    Schoenenberger, CA
    Hoh, JH
    BIOPHYSICAL JOURNAL, 1998, 74 (03) : 1564 - 1578
  • [44] Relative micromechanical mapping of living cells by atomic force microscopy
    AHassan, E
    Heinz, WF
    Antonik, MD
    DCosta, NP
    Nagaswaran, S
    Schoenenberger, CA
    Hoh, JH
    MOLECULAR BIOLOGY OF THE CELL, 1997, 8 : 351 - 351
  • [45] Relative Microelastic Mapping of Living Cells by Atomic Force Microscopy
    A-Hassan, E.
    Heinz, W. F.
    Antonik, M. D.
    D'Costa, N. P.
    1998, (74)
  • [46] Reduction and oxidation of oxide ion conductors with conductive atomic force microscopy
    Lee, Wonyoung
    Lee, Minhwan
    Kim, Young-Beom
    Prinz, Fritz B.
    NANOTECHNOLOGY, 2009, 20 (44)
  • [47] Electrical properties of ZnO nanorods studied by conductive atomic force microscopy
    Beinik, I.
    Kratzer, M.
    Wachauer, A.
    Wang, L.
    Lechner, R. T.
    Teichert, C.
    Motz, C.
    Anwand, W.
    Brauer, G.
    Chen, X. Y.
    Hsu, X. Y.
    Djurisic, A. B.
    JOURNAL OF APPLIED PHYSICS, 2011, 110 (05)
  • [48] Direct investigation of current transport in cells by conductive atomic force microscopy
    Zhao, W.
    Cheong, L. -Z.
    Xu, S.
    Cui, W.
    Song, S.
    Rourk, C. J.
    Shen, C.
    JOURNAL OF MICROSCOPY, 2020, 277 (01) : 49 - 57
  • [49] Atomic Force Microscopy Studies of Conductive Nanostructures in Solid Polymer Electrolytes
    Hiesgen, Renate
    Morawietz, Tobias
    Helmly, Stefan
    Galm, Ines
    Friedrich, K. Andreas
    POLYMER ELECTROLYTE FUEL CELLS 13 (PEFC 13), 2013, 58 (01): : 595 - 605
  • [50] Imaging and nanoprobing of graphene layers for interconnects by conductive atomic force microscopy
    Zhang, Li
    Katagiri, Masayuki
    Ishikura, Taishi
    Wada, Makoto
    Miyazaki, Hisao
    Nishide, Daisuke
    Matsumoto, Takashi
    Sakuma, Naoshi
    Kajita, Akihiro
    Sakai, Tadashi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2015, 54 (05)