The Effect of Relative Humidity in Conductive Atomic Force Microscopy

被引:0
|
作者
Yuan, Yue [1 ]
Lanza, Mario [1 ,2 ]
机构
[1] King Abdullah Univ Sci & Technol KAUST, Phys Sci & Engn Div, Mat Sci & Engn Program, Thuwal 23955, Saudi Arabia
[2] Natl Univ Singapore, Dept Mat Sci & Engn, Singapore 117575, Singapore
关键词
2D materials; conductive atomic force microscopy; metrology; nanoelectronics; relative humidity; OXIDES; SIO2-FILMS; VACUUM; THIN;
D O I
10.1002/adma.202405932
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Conductive atomic force microscopy (CAFM) analyzes electronic phenomena in materials and devices with nanoscale lateral resolution, and it is widely used by companies, research institutions, and universities. Most data published in the field of CAFM is collected in air at a relative humidity (RH) of 30-60%. However, the effect of RH in CAFM remains unclear because previous studies often made contradictory claims, plus the number of samples and locations tested is scarce. Moreover, previous studies on this topic did not apply current limitations, which can degrade the CAFM tips and generate false data. This article systematically analyzes the effect of RH in CAFM by applying ramped voltage stresses at over 17,000 locations on ten different samples (insulating, semiconducting, and conducting) under seven different RH. An ultra-reliable setup with a 110-pA current limitation during electrical stresses is employed, and excellent CAFM tip integrity after thousands of tests is demonstrated. It is found that higher RH results in increased currents due to the presence of a conductive water meniscus at the tip/sample junction, which increases the effective area for electron flow. This trend is observed in insulators and ultra-thin semiconductors; however, in thicker semiconductors the electron mean free path is high enough to mask this effect. Metallic samples show no dependence on RH. This study clarifies the effect of relative humidity in CAFM, enhances understanding of the technique, and teaches researchers how to improve the reliability of their studies in this field. In this article, the impact of relative humidity (RH) on conductive atomic force microscopy (CAFM) measurements is investigated. For insulating and ultra-thin (less than 5 nm) semiconducting samples, a RH at 4% results in lower and more inhomogeneous currents compared to RH = 54%. In contrast, for thicker semiconducting (above 5 nm) and metallic samples, RH has no significant effect. These observations are confirmed by over 17,000 tests at different locations of ten samples. image
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Conductive atomic force microscopy study of MBE GaN films
    Moore, J. C.
    Cooper, K. A.
    Xie, J.
    Morkoc, H.
    Baski, A. A.
    GALLIUM NITRIDE MATERIALS AND DEVICES, 2006, 6121
  • [32] Investigation of epitaxial GaN films by conductive atomic force microscopy
    Dogan, S
    Spradlin, J
    Xie, J
    Pomarico, AA
    Cingolani, R
    Huang, D
    Dickinson, J
    Baski, AA
    Morkoc, H
    Molnar, R
    NEW APPLICATIONS FOR WIDE-BANDGAP SEMICONDUCTORS, 2003, 764 : 395 - 400
  • [33] Current mapping of GaN films by conductive atomic force microscopy
    Pomarico, AA
    Huang, D
    Dickinson, J
    Baski, AA
    Cingolani, R
    Morkoç, H
    Molnar, R
    APPLIED PHYSICS LETTERS, 2003, 82 (12) : 1890 - 1892
  • [34] Electrical conductivities of nanosheets studied by conductive atomic force microscopy
    Yilmaz, Neval
    Ida, Shintaro
    Matsumoto, Yasumichi
    MATERIALS CHEMISTRY AND PHYSICS, 2009, 116 (01) : 62 - 66
  • [35] Hydrogenated Nanocrystalline Silicon Investigated by Conductive Atomic Force Microscopy
    Cavallini, A.
    Cavalcoli, D.
    Rossi, M.
    Tomasi, A.
    Pichaud, B.
    Texier, M.
    Le Donne, A.
    Pizzini, S.
    Chrastina, D.
    Isella, G.
    MICROSCOPY OF SEMICONDUCTING MATERIALS 2007, 2008, 120 : 301 - +
  • [36] Switching of nanosized filaments in NiO by conductive atomic force microscopy
    Nardi, F.
    Deleruyelle, D.
    Spiga, S.
    Muller, C.
    Bouteille, B.
    Ielmini, D.
    JOURNAL OF APPLIED PHYSICS, 2012, 112 (06)
  • [37] Conductive atomic force microscopy study of silica nanotrench structure
    Sun, Z. G.
    Kuramochi, H.
    Akinaga, H.
    Yu, H. H.
    Gu, E. D.
    APPLIED PHYSICS LETTERS, 2007, 90 (04)
  • [38] Different Evolution Behaviors of Adhesion Force with Relative Humidity at Silica/Silica and Silica/Graphene Interfaces Studied using Atomic Force Microscopy
    Lai, Tianmao
    Zhu, Ting
    Chen, Yuguo
    Guo, Mingli
    LANGMUIR, 2021, 37 (44) : 13075 - 13084
  • [39] Characterization of surface ionic activity of proton conductive membranes by conductive atomic force microscopy
    Nguyen, TV
    Nguyen, MV
    Lin, GY
    Rao, NX
    Xie, X
    Zhu, DM
    ELECTROCHEMICAL AND SOLID STATE LETTERS, 2006, 9 (02) : A88 - A91
  • [40] Reactivity of gypsum faces according to the relative humidity by scanning force microscopy
    Finot, E
    Lesniewska, E
    Mutin, JC
    Goudonnet, JP
    SURFACE SCIENCE, 1997, 384 (1-3) : 201 - 217