Monitoring bivariate zero-inflated Poisson processes: an alternative to copula-based bivariate attribute control chart

被引:0
|
作者
Pal, Surajit [1 ]
Gauri, Susanta Kumar [2 ]
机构
[1] Indian Stat Inst, SQC & OR Unit, Chennai, India
[2] Indian Stat Inst, SQC & OR Unit, 203 BT Rd, Kolkata 700108, India
关键词
Bivariate attribute control chart (BACC); Bivariate zero-inflated Poisson (BZIP) process; Monitoring; MODEL; FAMILY;
D O I
10.1080/03610918.2024.2389931
中图分类号
O21 [概率论与数理统计]; C8 [统计学];
学科分类号
020208 ; 070103 ; 0714 ;
摘要
Occurrences of two (or more) types of defects are not uncommon in high quality (or zero-inflated) processes. Bivariate (or multivariate) attribute control charts are required to be developed for monitoring such processes. Fatahi et al. (2012) introduced the idea of applying copula function to derive joint distribution of two correlated zero-inflated Poisson distributions, which can be used to develop bivariate attribute control chart (BACC) for monitoring bivariate zero-inflated Poisson (BZIP) processes. However, the copula-based model often fails to represent bivariate zero-inflated data, which we come across in real-life situations. Li et al. (1999) model for BZIP distribution is quite flexible. Thus, it can overcome the limitations of Fatahi et al. (2012) model. In this paper, BACC is developed based on Li et al. (1999) model. The performances of the proposed BACC, in terms of in-control and out-of-control average run lengths, are evaluated extensively using simulations. The results show that the proposed BACC are well capable of detecting shifts in the parameters of a BZIP process. Further, two case studies on BZIP process data obtained by past researchers reveal that the BACC developed based on Li et al. (1999) model is more effective than the BACC developed based on copula-based model.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Monitoring of zero-inflated Poisson processes with EWMA and DEWMA control charts
    Alevizakos, Vasileios
    Koukouvinos, Christos
    QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2020, 36 (01) : 88 - 111
  • [22] A one-chart scheme for joint monitoring of the two parameters of zero-inflated Poisson processes
    Pal, Surajit
    Gauri, Susanta Kumar
    COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 2024,
  • [23] Semiparametric bivariate zero-inflated Poisson models with application to studies of abundance for multiple species
    Arab, Ali
    Holan, Scott H.
    Wikle, Christopher K.
    Wildhaber, Mark L.
    ENVIRONMETRICS, 2012, 23 (02) : 183 - 196
  • [24] A Class of Copula-Based Bivariate Poisson Time Series Models with Applications
    Alqawba, Mohammed
    Fernando, Dimuthu
    Diawara, Norou
    COMPUTATION, 2021, 9 (10)
  • [25] Control chart for detecting the scale parameter of the zero-inflated Poisson model
    Zhao, Aijun
    Liu, Liu
    Lai, Xin
    Chong, Ka Chun
    QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2024, 40 (06) : 3387 - 3406
  • [26] Attribute Control Charts Using Generalized Zero-inflated Poisson Distribution
    Chen, Nan
    Zhou, Shiyu
    Chang, Tzyy-Shuh
    Huang, Howard
    QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2008, 24 (07) : 793 - 806
  • [27] A Comparison of Bivariate Zero-Inflated Poisson Inverse Gaussian Regression Models with and without Exposure Variables
    Ermawati, Ermawati
    Purhadi, Purhadi
    Rahayu, Santi Puteri
    SYMMETRY-BASEL, 2022, 14 (02):
  • [28] Analysis of Blood Transfusion Data Using Bivariate Zero-Inflated Poisson Model: A Bayesian Approach
    Mohammadi, Tayeb
    Kheiri, Soleiman
    Sedehi, Morteza
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2016, 2016
  • [29] Copula-based Markov zero-inflated count time series models with application
    Alqawba, Mohammed
    Diawara, Norou
    JOURNAL OF APPLIED STATISTICS, 2021, 48 (05) : 786 - 803
  • [30] Cumulative sum control charts for monitoring zero-inflated COM-Poisson processes
    Tasias, Konstantinos A.
    Alevizakos, Vasileios
    QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2024, 40 (05) : 2891 - 2903