Simultaneous determination of dopamine and folic acid using chitosan-carrageenan hydrogel/graphene oxide modified glassy carbon electrode

被引:0
|
作者
Postolovic, Katarina S. [1 ]
Stanic, Zorka D. [1 ]
机构
[1] Univ Kragujevac, Fac Sci, Dept Chem, Kragujevac, Serbia
关键词
Dopamine; Folic acid; Chitosan hydrogel; Carrageenan hydrogel; Graphene oxide; Voltammetric sensor; POLYELECTROLYTE COMPLEXES; PASTE ELECTRODE; ASCORBIC-ACID; URIC-ACID; SPECTROFLUOROMETRIC DETERMINATION; ELECTROCHEMICAL DETERMINATION; VOLTAMMETRIC DETERMINATION; SIMULTANEOUS RESOLUTION; SELECTIVE DETERMINATION; KAPPA-CARRAGEENAN;
D O I
10.1016/j.microc.2024.111660
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dopamine and folic acid are compounds that coexist in biological fluids, essential for metabolic processes and central nervous system function. The fast, sensitive, and accurate detection of these compounds in biological and pharmaceutical samples holds significant importance for human health assessment and the pharmaceutical industry. An innovative and efficacious electrochemical sensor for the simultaneous quantification of dopamine and folic acid was developed. This sensor was based on the glassy carbon electrode modified with chitosan kappa- carrageenan hydrogel, enriched with the addition of a catalytically active component - graphene oxide. This modification procedure significantly improved the adsorption of the analytes onto the electrode surface thanks to the established favorable intermolecular interactions, thereby enhancing the electrical conductivity of the electrode. The sensor demonstrated an extensive linear response range of the cathodic current in relation to the concentration of dopamine and folic acid, both when quantified individually and simultaneously. Key advantages of this sensor include the obtained low detection limits for both analytes (5.65 x 10(-9) mol/L for dopamine, and 1.88 x 10(-7)mol/L- 7 mol/L for folic acid), electrode selectivity, stability, and good reproducibility of results. The results achieved in this study signify the considerable potential of the developed sensor for the determination of dopamine and folic acid in diverse sample types. Additionally, this work presents an effective method for sensitive detection of selected analytes, and also highlights the utilization of nontoxic compounds in the preparation of a biocompatible sensor, given its considerable potential for future practical applications in various fields.
引用
下载
收藏
页数:14
相关论文
共 50 条
  • [1] Simultaneous determination of dopamine, uric acid and ascorbic acid using a glassy carbon electrode modified with reduced graphene oxide
    Wang, Huiwen
    Ren, Fangfang
    Wang, Caiqin
    Yang, Beibei
    Bin, Duan
    Zhang, Ke
    Du, Yukou
    RSC ADVANCES, 2014, 4 (51) : 26895 - 26901
  • [2] Modified Glassy Carbon Electrode with Polypyrrole Nanocomposite for the Simultaneous Determination of Ascorbic acid, Dopamine, Uric acid, and Folic Acid
    Ghanbari, Khadijeh
    Bonyadi, Sepideh
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2020, 11 (01) : 68 - 83
  • [3] Chitosan incorporating cetyltrimethylammonium bromide modified glassy carbon electrode for simultaneous determination of ascorbic acid and dopamine
    Zou, Xuelian
    Luo, Liqiang
    Ding, Yaping
    Wu, Qingsheng
    ELECTROANALYSIS, 2007, 19 (17) : 1840 - 1844
  • [4] Simultaneous Electrochemical Detection of Dopamine and Ascorbic Acid Using an Iron Oxide/Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Peik-See, Teo
    Pandikumar, Alagarsamy
    Nay-Ming, Huang
    Hong-Ngee, Lim
    Sulaiman, Yusran
    SENSORS, 2014, 14 (08): : 15227 - 15243
  • [5] Simultaneous electrochemical detection of dopamine and ascorbic acid using an iron oxide/reduced graphene oxide modified glassy carbon electrode
    Peik-See, Teo
    Pandikumar, Alagarsamy
    Nay-Ming, Huang
    Hong-Ngee, Lim
    Sulaiman, Yusran
    Sensors (Switzerland), 2014, 14 (08): : 15227 - 15243
  • [7] Electrochemical deposition of gold nanoparticles on reduced graphene oxide modified glassy carbon electrode for simultaneous determination of levodopa, uric acid and folic acid
    Benvidi, Ali
    Dehghani-Firouzabadi, Afsaneh
    Mazloum-Ardakani, Mohammad
    Mirjalili, Bi-Bi Fatemeh
    Zare, Reza
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 736 : 22 - 29
  • [8] Simultaneous determination of dopamine, ascorbic acid by polyethylene oxide (PEO) covalently modified glassy carbon electrode
    Gong, Wei
    Dou, Zhi-Yu
    Liu, Ping
    Cai, Xue-Ying
    He, Xing-quan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 666 : 62 - 66
  • [9] Differential Pulse Voltammetric Determination of Folic Acid in the Presence of Ascorbic Acid using A Glassy Carbon Electrode Modified with Reduced Graphene Oxide
    Abd-Elsabour, Mohamed
    Toghan, Arafat
    Abo-bakr, Ahmed M.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (08): : 789 - 805
  • [10] 3D Graphene hydrogel - gold nanoparticles nanocomposite modified glassy carbon electrode for the simultaneous determination of ascorbic acid, dopamine and uric acid
    Zhu, Qing
    Bao, Jing
    Huo, Danqun
    Yang, Mei
    Hou, Changjun
    Guo, Jianfeng
    Chen, Mei
    Fa, Huanbao
    Luo, Xiaogang
    Ma, Yi
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 238 : 1316 - 1323