Dose assessment in petrous bone CT: Effect of tube current modulation and scan length

被引:0
|
作者
Saga, Zouhir [1 ]
Rahmouni, Abdelaali [1 ]
Talbi, Mohammed [2 ]
Anam, Choirul [3 ]
Rezzouk, Abdellah [1 ]
机构
[1] Sidi Mohamed Ben Abdellah Univ, Fac Sci Dhar El Mahraz, Dept Phys, Lab Solid State Phys, Fes, Morocco
[2] Ibn Tofail Univ, Higher Inst Nursing Profess & Hlth Tech, Fac Sci, Rabat Dept Phys,Lab Mat & Subatom Phys, Kenitra, Morocco
[3] Diponegoro Univ, Fac Math & Sci, Dept Phys, Semarang, Indonesia
关键词
Petrous bone CT; TCM; Scan length; DLP; Effective dose;
D O I
10.1016/j.radphyschem.2024.112125
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The aim of this study is to compare the dosimetric performance of two CT acquisition protocols for the petrous bone: a standard fixed mAs protocol and a protocol using tube current modulation (TCM). By analyzing the scan length, dose-length product (DLP) and effective dose (ED) obtained with each protocol, we investigate whether TCM offers an advantage in terms of dose reduction while maintaining comparable image quality. To this end, 249 patients (women: 52%; men: 48%) were included in this study. The first center used TCM (120 kVp, 150 mA reference) for image acquisition, while the other centers opted for fixed mAs values. Acceptability of image quality was assessed using a standardized phantom (model 610 AAPM) by measuring noise uniformity and accuracy, contrast-to-noise ratio (CNR) and spatial resolution. The CTDIvol was not significantly different between center A and the other centers (p > 0.05), while DLP and ED were significantly different (p < 0.001), being reduced by a factor of 2 and 2.23 for scan length. We concluded that a scan with a 14.28% decrease in tube voltage from 140 kVp (136-170-210) mAs fixed to 120 kVp with TCM to 150 mA reference in helical scan mode can be recommended as an optimized protocol during CT examination of petrous bone while reducing DLP and ED to 50% without loss of diagnostic accuracy.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Effect of CT Scan Parameters on Adult and Pediatric CT Dose When Using Automatic Tube Current Modulation
    Winslow, J.
    Kappadath, S.
    MEDICAL PHYSICS, 2010, 37 (06) : 3102 - +
  • [2] Monte Carlo Simulation and Dose Calculation of Chest CT Scan with Tube Current Modulation
    Gao, Y.
    Ding, A.
    Zhang, D.
    Liu, B.
    Caracappa, P.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [3] Dosimetric Effect of the Position of Arms in Torso CT Scan with Tube Current Modulation
    Liu, H.
    Gao, Y.
    Zhuo, W.
    Wu, J.
    Xu, X.
    MEDICAL PHYSICS, 2015, 42 (06) : 3542 - 3542
  • [4] Assessment of tube current modulation in pelvic CT
    Iball, GR
    Brettle, DS
    Moore, AC
    BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (937): : 62 - 70
  • [5] Eye Lens Dose Reduction From CT Scan Using Organ Based Tube Current Modulation
    Liu, H.
    Liu, T.
    Xu, X.
    Wu, J.
    Zhuo, W.
    MEDICAL PHYSICS, 2015, 42 (06) : 3250 - 3250
  • [6] Effect of scan projection radiography coverage on tube current modulation in pediatric and adult chest CT
    Perisinakis, Kostas
    Ntoufas, Nikos
    Velivassaki, Mary
    Tzedakis, Antonis
    Myronakis, Marios
    Hatzidakis, Adam
    Damilakis, John
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2020, 30 (04): : 259 - 270
  • [7] Reducing Scanogram Dose Without Affecting the Planned Tube Current Modulation of a Diagnostic Abdomen/pelvis CT Scan
    Zhang, D.
    Angel, E.
    MEDICAL PHYSICS, 2012, 39 (06) : 3634 - 3635
  • [8] Calculation of dose reduction by tube current modulation in pediatric CT
    Schmidt, B
    Greess, H
    Wolf, H
    Kalender, WA
    RADIOLOGY, 2001, 221 : 365 - 366
  • [9] Absorption dose reduction by tube current modulation in CT system
    Nagaoka, T
    Miyazaki, O
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 719 - 731
  • [10] Patient Specific Tube Current Modulation for CT Dose Reduction
    Jin, Yannan
    Yin, Zhye
    Yao, Yangyang
    Wang, Hui
    Wu, Mingye
    Kalra, Mannudeep
    De Man, Bruno
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412