On the measurement of tower-footing impedance/resistance

被引:0
|
作者
Visacro, Silverio [1 ]
Vale, Maria Helena M. [1 ]
Pereira, Barbara [1 ]
Silveira, Fernando H. [1 ]
机构
[1] UFMG Fed Univ Minas Gerais, LRC Lightning Res Ctr, Belo Horizonte, Brazil
关键词
Lightning response of tower -footing electrodes; Tower -footing impulse impedance; Tower -footing resistance; Measurement of the tower -footing impedance; and resistance; LIGHTNING SURGE RESPONSE; GROUNDING ELECTRODES;
D O I
10.1016/j.epsr.2024.110618
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work addressed concepts of concise parameters that can be quantified by means of measurement for qualifying the lightning response of tower-footing electrodes, namely the first return stroke impulse impedance ZP, the low frequency resistance RLF and the 25 kHz harmonic impedance Z25kHz. The significant difference among the values of these parameters for any given arrangement of electrodes buried in the same soil was highlighted, along with their use for estimating the expected lightning response of the transmission line (TL) tower. The difficulties for implementing the methodologies for measurement of RLF and Z25kHz were analyzed, and respective solutions were recommended. The overcoming of the challenge of determining reliable values of ZP from measured values of the two other parameters was addressed as well.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Seasonal Variations of Tower Footing Impedance in Various Transmission Line Grounding Systems
    Wang, Chenyang
    Liang, Xiaodong
    Adajar, Emerson
    Loewen, Paul
    2020 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2020,
  • [22] Study on transmission-line arresters for tower with high footing resistance
    Hayashi, Tomohiro
    Mizuno, Yukio
    Naito, Katsuhiko
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 2456 - 2460
  • [23] Combined Tacs-Models for Footing Tower Resistance Considering Ground Ionization
    Morales, John A.
    Orduna, Eduardo. A.
    Cabral, Roberto J.
    Bretas, Arturo S.
    2014 NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2014,
  • [24] Effect of Earthing Enhancing Compound (EEC) on Improving Tower Footing Resistance of a 500 kV Tower in a Rocky Area
    Nasir, Nur Alia Farina Mohd
    Ab Kadir, Mohd Zainal Abidin
    Osman, Miszaina
    Abd Rahman, Muhamad Safwan
    Amirulddin, Ungku Anisa Ungku
    Nasir, Mohd Solehin Mohd
    Zaini, Nur Hazirah
    Ali, Nik Hakimi Nik
    APPLIED SCIENCES-BASEL, 2021, 11 (12):
  • [25] Influence of Lightning Current Parameters and Earthing System Designs on Tower Footing Impedance of 500 kV Lines
    Nasir, Nur Alia Farina Mohamad
    Ab Kadir, Mohd Zainal Abidin
    Osman, Miszaina
    Abd Rahman, Muhamad Safwan
    Amirulddin, Ungku Anisa Ungku
    Nasir, Mohd Solehin Mohd
    Zaini, Nur Hazirah
    Ali, Nik Hakimi Nik
    ENERGIES, 2021, 14 (16)
  • [26] Research on Impulse Impedance Measurement for Grounding Device of Transmission Tower
    Si Wen-Rong
    Fu Chen-Zhao
    Lu Bing-Bing
    Guo Xiang
    Xu Zhi-Bing
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [27] Measurement and Analysis of Impulse Grounding Impedance for UHV Transmission Tower
    Si, W. R.
    Fu, C. Z.
    Wu, T. Y.
    Wang, S. J.
    Yuan, P.
    2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [28] Novel Method for Tower Grounding Resistance Measurement
    Zhang, Zhanlong
    Wu, Hao
    Cao, Qingzhou
    Luo, Chen
    Xiao, Dongping
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2017, 45 (13) : 1404 - 1412
  • [29] Variation of Tower Footing Resistance on the Lightning Surge Propagation through Overhead Power Distribution Lines
    Mariut, Elena Larisa
    Helerea, Elena
    ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2016, 16 (01) : 99 - 106
  • [30] Accurate modelling of rod driven tower footing
    Almeida, ME
    deBarros, MTC
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (03) : 1606 - 1609