Sequence comparison of spoiled gradient echo and balanced steady-state free precession for pulmonary free-breathing proton MRI in patients and healthy volunteers: Correspondence, repeatability, and validation with dynamic contrast-enhanced MRI

被引:0
|
作者
Hahn, Jonah J. [1 ]
Voskrebenzev, Andreas [1 ,2 ]
Behrendt, Lea [1 ,2 ]
Klimes, Filip [1 ,2 ]
Poehler, Gesa H. [1 ,2 ]
Wacker, Frank [1 ,2 ]
Vogel-Claussen, Jens [1 ,2 ]
机构
[1] Hannover Med Sch, Dept Diagnost & Intervent Radiol, Hannover, Germany
[2] Biomed Res Endstage & Obstruct Lung Dis, Hannover, Germany
关键词
bSSFP; Fourier decomposition; free-breathing V/Q; lung MRI; PREFUL; SPGRE; BOLUS-TRACKING DATA; FOURIER DECOMPOSITION; VENTILATION; PERFUSION; LUNG; DECONVOLUTION; COPD;
D O I
10.1002/nbm.5209
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Phase-resolved functional lung (PREFUL) MRI is a proton-based, contrast agent-free technique derived from the Fourier decomposition approach to measure regional ventilation and perfusion dynamics during free-breathing. Besides the necessity of extensive PREFUL postprocessing, the utilized MRI sequence must fulfill specific requirements. This study investigates the impact of sequence selection on PREFUL-MRI-derived functional parameters by comparing the standard spoiled gradient echo (SPGRE) sequence with a lung-optimized balanced steady-state free precession (bSSFP) sequence, thereby facilitating PREFULs clinical application in pulmonary disease assessment. This study comprised a prospective dataset of healthy volunteers and a retrospective dataset of patients with suspected chronic thromboembolic pulmonary hypertension. Both cohorts underwent PREFUL-MRI with both sequences to assess the correspondence of PREFUL ventilation and perfusion parameters (A). Additionally, healthy subjects were scanned a second time to evaluate repeatability (B), whereas patients received dynamic contrast-enhanced (DCE)-MRI, considered the perfusion gold standard for comparison with PREFUL-MRI (C). Signal-to-noise ratio (SNR), calculated from the unprocessed images, was compared alongside median differences of PREFUL-MRI-derived parameters using a paired Wilcoxon signed rank test. Further evaluations included calculation of the Pearson correlation, intraclass-correlation coefficient for repeatability assessment, and spatial overlap (SO) for regional comparison of PREFUL-MRI and DCE-MRI. bSSFP showed a clear SNR advantage over SPGRE (median: 23 vs. 9, p < 0.001). (A) Despite significant differences, parameter values were strongly correlated (r >= 0.75). After thresholding, binary maps showed high healthy overlap across both cohorts (SOHealthy > 86%) and high defect overlap in the patient cohort (SODefect >= 48%). (B) bSSFP demonstrated slightly higher repeatability across most parameters. (C) Both sequences demonstrated comparable correspondence to DCE-MRI, with SPGRE excelling in absolute quantification and bSSFP in spatial agreement. Although bSSFP showed superior SNR results, both sequences displayed spatial defect concordance and highly correlated PREFUL parameters with deviations regarding repeatability and alignment with DCE-MRI.
引用
收藏
页数:22
相关论文
共 45 条
  • [41] Non-Contrast-Enhanced MR Portography With Balanced Steady-State Free-Precession Sequence and Time-Spatial Labeling Inversion Pulses: Comparison of Imaging With Flow-In and Flow-Out Methods
    Furuta, Akihiro
    Isoda, Hiroyoshi
    Yamashita, Rikiya
    Ohno, Tsuyoshi
    Kawahara, Seiya
    Shimizu, Hironori
    Fujimoto, Koji
    Kido, Aki
    Kusahara, Hiroshi
    Togashi, Kaori
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (03) : 583 - 587
  • [42] Clinical Value of Noncontrast-Enhanced Radial Quiescent-Interval Slice-Selective (QISS) Magnetic Resonance Angiography for the Diagnosis of Acute Pulmonary Embolism Compared to Contrast-Enhanced Computed Tomography and Cartesian Balanced Steady-State Free Precession
    Salehi Ravesh, Mona
    Tesch, Karolin
    Lebenatus, Annett
    Koktzoglou, Ioannis
    Edelman, Robert R.
    Eden, Matthias
    Langguth, Patrick
    Graessner, Joachim
    Jansen, Olav
    Both, Marcus
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 52 (05) : 1510 - 1524
  • [43] Left Gastric Vein Visualization with Hepatopetal Flow Information in Healthy Subjects Using Non-Contrast-Enhanced Magnetic Resonance Angiography with Balanced Steady-State Free-Precession Sequence and Time-Spatial Labeling Inversion Pulse
    Furuta, Akihiro
    Isoda, Hiroyoshi
    Ohno, Tsuyoshi
    Ono, Ayako
    Yamashita, Rikiya
    Arizono, Shigeki
    Kido, Aki
    Sakashita, Naotaka
    Togashi, Kaori
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (01) : 32 - 39
  • [44] Optimization of non-contrast-enhanced MR angiography of the renal artery with three-dimensional balanced steady-state free-precession and time-spatial labeling inversion pulse (time-SLIP) at 3T MRI, in relation to age and blood velocity
    Kurata, Yasuhisa
    Kido, Aki
    Fujimoto, Koji
    Kiguchi, Kayo
    Takakura, Kyoko
    Moribata, Yusaku
    Shitano, Fuki
    Himoto, Yuki
    Fushimi, Yasutaka
    Okada, Tomohisa
    Togashi, Kaori
    ABDOMINAL RADIOLOGY, 2016, 41 (01) : 119 - 126
  • [45] Optimization of non-contrast-enhanced MR angiography of the renal artery with three-dimensional balanced steady-state free-precession and time-spatial labeling inversion pulse (time-SLIP) at 3T MRI, in relation to age and blood velocity
    Yasuhisa Kurata
    Aki Kido
    Koji Fujimoto
    Kayo Kiguchi
    Kyoko Takakura
    Yusaku Moribata
    Fuki Shitano
    Yuki Himoto
    Yasutaka Fushimi
    Tomohisa Okada
    Kaori Togashi
    Abdominal Radiology, 2016, 41 : 119 - 126