Sequence comparison of spoiled gradient echo and balanced steady-state free precession for pulmonary free-breathing proton MRI in patients and healthy volunteers: Correspondence, repeatability, and validation with dynamic contrast-enhanced MRI

被引:0
|
作者
Hahn, Jonah J. [1 ]
Voskrebenzev, Andreas [1 ,2 ]
Behrendt, Lea [1 ,2 ]
Klimes, Filip [1 ,2 ]
Poehler, Gesa H. [1 ,2 ]
Wacker, Frank [1 ,2 ]
Vogel-Claussen, Jens [1 ,2 ]
机构
[1] Hannover Med Sch, Dept Diagnost & Intervent Radiol, Hannover, Germany
[2] Biomed Res Endstage & Obstruct Lung Dis, Hannover, Germany
关键词
bSSFP; Fourier decomposition; free-breathing V/Q; lung MRI; PREFUL; SPGRE; BOLUS-TRACKING DATA; FOURIER DECOMPOSITION; VENTILATION; PERFUSION; LUNG; DECONVOLUTION; COPD;
D O I
10.1002/nbm.5209
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Phase-resolved functional lung (PREFUL) MRI is a proton-based, contrast agent-free technique derived from the Fourier decomposition approach to measure regional ventilation and perfusion dynamics during free-breathing. Besides the necessity of extensive PREFUL postprocessing, the utilized MRI sequence must fulfill specific requirements. This study investigates the impact of sequence selection on PREFUL-MRI-derived functional parameters by comparing the standard spoiled gradient echo (SPGRE) sequence with a lung-optimized balanced steady-state free precession (bSSFP) sequence, thereby facilitating PREFULs clinical application in pulmonary disease assessment. This study comprised a prospective dataset of healthy volunteers and a retrospective dataset of patients with suspected chronic thromboembolic pulmonary hypertension. Both cohorts underwent PREFUL-MRI with both sequences to assess the correspondence of PREFUL ventilation and perfusion parameters (A). Additionally, healthy subjects were scanned a second time to evaluate repeatability (B), whereas patients received dynamic contrast-enhanced (DCE)-MRI, considered the perfusion gold standard for comparison with PREFUL-MRI (C). Signal-to-noise ratio (SNR), calculated from the unprocessed images, was compared alongside median differences of PREFUL-MRI-derived parameters using a paired Wilcoxon signed rank test. Further evaluations included calculation of the Pearson correlation, intraclass-correlation coefficient for repeatability assessment, and spatial overlap (SO) for regional comparison of PREFUL-MRI and DCE-MRI. bSSFP showed a clear SNR advantage over SPGRE (median: 23 vs. 9, p < 0.001). (A) Despite significant differences, parameter values were strongly correlated (r >= 0.75). After thresholding, binary maps showed high healthy overlap across both cohorts (SOHealthy > 86%) and high defect overlap in the patient cohort (SODefect >= 48%). (B) bSSFP demonstrated slightly higher repeatability across most parameters. (C) Both sequences demonstrated comparable correspondence to DCE-MRI, with SPGRE excelling in absolute quantification and bSSFP in spatial agreement. Although bSSFP showed superior SNR results, both sequences displayed spatial defect concordance and highly correlated PREFUL parameters with deviations regarding repeatability and alignment with DCE-MRI.
引用
收藏
页数:22
相关论文
共 45 条
  • [31] 3D-assessment of RVOT dimensions prior percutaneous pulmonary valve implantation: comparison of contrast-enhanced magnetic resonance angiography versus 3D steady-state free precession sequence
    Ebel, Sebastian
    Gottschling, Sebastian
    Buzan, Maria T. A.
    Grothoff, Matthias
    Daehnert, Ingo
    Wagner, Robert
    Graefe, Daniel
    Lurz, Philipp
    Gutberlet, Matthias
    Luecke, Christian
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (08): : 1453 - 1463
  • [32] 3D-assessment of RVOT dimensions prior percutaneous pulmonary valve implantation: comparison of contrast-enhanced magnetic resonance angiography versus 3D steady-state free precession sequence
    Sebastian Ebel
    Sebastian Gottschling
    Maria T. A. Buzan
    Matthias Grothoff
    Ingo Dähnert
    Robert Wagner
    Daniel Gräfe
    Philipp Lurz
    Matthias Gutberlet
    Christian Lücke
    The International Journal of Cardiovascular Imaging, 2019, 35 : 1453 - 1463
  • [33] Retrospective assessment of at-risk myocardium in reperfused acute myocardial infarction patients using contrast-enhanced balanced steady-state free-precession cardiovascular magnetic resonance at 3T with SPECT validation
    Sun, Zheng
    Zhang, Qiuhang
    Zhao, Huan
    Yan, Chengxi
    Yang, Hsin-Jung
    Li, Debiao
    Li, Kuncheng
    Liu, Zhi
    Yang, Qi
    Dharmakumar, Rohan
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [34] Free-breathing contrast-enhanced multiphase MRI of the liver in patients with a high risk of breath-holding failure: comparison of compressed sensing-accelerated radial and Cartesian acquisition techniques
    Choi, Eun Sun
    Kim, Jin Sil
    Nickel, Marcel Dominik
    Sung, Jae Kon
    Lee, Jeong Kyong
    ACTA RADIOLOGICA, 2022, 63 (11) : 1453 - 1462
  • [35] T2-Prepared Steady-State Free-Precession Blood Oxygenation Level-Dependent MRI in Patients with Coronary Artery Disease and Normal Volunteers: Validation against PET
    Karamitsos, Theodoros D.
    Reclo-Mayoral, Alejandro
    Arnold, Jayanth R.
    Leccisotti, Lucia
    Bhamra-Ariza, Paul
    Howells, Ruairidh K.
    Searle, Nick
    Robson, Matthew D.
    Rimoldi, Omella E.
    Camici, Paolo G.
    Neubauer, Stefan
    Selvanayagam, Joseph B.
    CIRCULATION, 2008, 118 (18) : S691 - S692
  • [36] Free-breathing radial 3D fat-suppressed T1-weighted gradient echo (r-VIBE) sequence for assessment of pulmonary lesions: a prospective comparison of CT and MRI
    Yu, Nan
    Duan, Haifeng
    Yang, Chuangbo
    Yu, Yong
    Dang, Shan
    CANCER IMAGING, 2021, 21 (01)
  • [37] Free-breathing radial 3D fat-suppressed T1-weighted gradient echo (r-VIBE) sequence for assessment of pulmonary lesions: a prospective comparison of CT and MRI
    Nan Yu
    Haifeng Duan
    Chuangbo Yang
    Yong Yu
    Shan Dang
    Cancer Imaging, 21
  • [38] Free-breathing 3D steady-state free precession coronary MR angiography with radial k-space sampling:: Comparison with cartesian k-space sampling and cartesian gradient-echo coronary MR angiography -: Pilot study
    Spuentrup, E
    Katoh, M
    Buecker, A
    Manning, WJ
    Schaeffter, T
    Nguyen, TH
    Kühl, HP
    Stuber, M
    Botnar, RM
    Günther, RW
    RADIOLOGY, 2004, 231 (02) : 581 - 586
  • [39] Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient Echo Sequence A Viable Alternative for Contrast-Enhanced Liver Imaging in Patients Unable to Suspend Respiration
    Chandarana, Hersh
    Block, Tobias K.
    Rosenkrantz, Andrew B.
    Lim, Ruth P.
    Kim, Danny
    Mossa, David J.
    Babb, James S.
    Kiefer, Berthold
    Lee, Vivian S.
    INVESTIGATIVE RADIOLOGY, 2011, 46 (10) : 648 - 653
  • [40] Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient-Echo Sequence for Contrast-Enhanced Pediatric Spinal Imaging: Comparison With T1-Weighted Turbo Spin-Echo Sequence
    Cho, Hyun-Hae
    Choi, Young Hun
    Cheon, Jung-Eun
    Lee, So Mi
    Kim, Woo Sun
    Kim, In-One
    Paek, MunYoung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 177 - 182