Validity of Endometrial Cavity Length on 3D Pelvic Ultrasound before Endometrial Ablation

被引:0
|
作者
Shine, Kayla [1 ]
Cowherd, Rachael [2 ]
Rowin, Alexandra [2 ]
Soora, Raksha [2 ]
Meglin, Michelle [2 ]
机构
[1] Med Univ South Carolina, Coll Med, Charleston, SC USA
[2] Med Univ South Carolina, Dept Obstet & Gynecol, Charleston, SC USA
关键词
endometrial ablation; endometrial cavity length; midcoronal plane; UTERINE; MULTICENTER; UTERUS; WOMEN; 2D;
D O I
10.14423/SMJ.0000000000001736
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: This study aimed to compare endometrial cavity length measurements obtained by preoperative three-dimensional (3D) reconstruction of coronal images on pelvic ultrasound with intraoperative endometrial cavity measurements obtained in advance of Minerva endometrial ablation. Methods: This was a retrospective cohort study of 41 individuals who underwent a Minerva endometrial ablation between August 1, 2018 and March 15, 2022 at a single academic medical center. Patients were excluded if they had an in-clinic ablation or no ultrasound with 3D uterine volume within 180 days before surgery. Physician sonologists measured the endometrial cavity length using 3D coronal reconstruction of the cavity. Two measurements were obtained by separate physicians who were blinded to intraoperative values. Intraoperative endometrial cavity lengths were obtained from operative reports. A Bland-Altman plot was used to evaluate the agreement of intraoperative and ultrasound measurements. Results: The mean intraoperative endometrial cavity length (50.7 +/- 7.8 mm) was greater than the mean endometrial cavity length by 3D coronal reconstruction of pelvic ultrasound (36.1 +/- 6.2 mm, P < 0.0001). The average difference between intraoperative and ultrasound measurements of cavity length was 14.6 +/- 9.0 mm. The agreement between measurements was poor (Lin's concordance correlation coefficient 0.06). Using a Bland-Altman plot, the limits of agreement (-3.1 to 32 mm) exceeded the a priori acceptable limits of agreement (-10 to 10 mm). Conclusions: Our findings suggest that preoperative coronal endometrial cavity length measurements by ultrasound are not a valid substitute for intraoperative measurements before Minerva ablation.
引用
收藏
页码:599 / 602
页数:4
相关论文
共 50 条
  • [21] 3D ultrasound assessment of endometrial junctional zone anatomy as a predictor of the outcome of ICSI cycles
    Maged, Ahmed M.
    Ramzy, Abdel-Maguid
    Ghar, Mona Aboul
    El Shenoufy, Hossam
    Allah, Sherine H. Gad
    Wahba, Amr H.
    ElKateb, AbdAllah Y.
    Hwedi, Noha
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2017, 212 : 160 - 165
  • [22] Diagnostic value of endometrial volume and flow parameters under 3D ultrasound acquisition in combination with serum CA125 in endometrial lesions
    Liao, Yu-Mei
    Li, Ya
    Yu, Hong-Xia
    Li, Yuan-Kun
    Du, Jie-Hua
    Chen, Hui
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2021, 60 (03): : 492 - 497
  • [23] 3D ULTRASOUND IMAGING OF PELVIC PROLAPSE
    Bard, Robert L.
    LASERS IN SURGERY AND MEDICINE, 2018, 50 (04) : 377 - 377
  • [24] COMPARISON OF 3D/4D ULTRASOUND TO 3D SALINE INFUSED SONOHYSTEROGRAPHYFOR EVALUATION OF ENDOMETRIAL POLYPS IN PRE AND POSTMENOPAUSAL WOMEN
    Rodriguez B, M. A.
    Gualtieri, M.
    Mouhayar, Y.
    Mejia, A.
    Brookfield, K. F.
    Cruz-Pachano, F.
    FERTILITY AND STERILITY, 2012, 98 (03) : S39 - S39
  • [25] ACCURACY OF 2D AND 3D ULTRASOUND IMAGING IN THE ANATOMICAL EVALUATION OF TUMOR INVASION IN ENDOMETRIAL CANCER
    Fuso, L.
    Facelli, V.
    Ottino, L.
    Mariani, L.
    De Rosa, G.
    Menato, G.
    Ferrero, A.
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2017, 27 : 197 - 197
  • [26] ACCURACY OF 2D AND 3D ULTRASOUND IMAGING IN THE ANATOMICAL EVALUATION OF TUMOR INVASION IN ENDOMETRIAL CANCER
    Fuso, L.
    Facelli, V.
    Ottino, L.
    Mariani, L.
    De Rosa, G.
    Menato, G.
    Ferrero, A.
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2017, 27 : 1086 - 1086
  • [27] Preoperative Evaluation of 3D-MRI on the Depth of Myometrial Invasion of Endometrial Carcinoma: 3D Study of Endometrial Carcinoma
    Fu, Jiaxin
    Cui, Yuhui
    Xu, Liqun
    Shen, Ping
    Liu, Xilong
    Chen, Chunlin
    Liu, Ping
    CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2022, 49 (10):
  • [28] Ultrasound - guided aspiration of blood into endometrial cavity in patients with istmocele before the embryo transfer: a pilot study
    Tafi, Emanuela
    Racca, Annalisa
    Erasmo, Ilaria
    Ferrero, Simone
    GYNECOLOGICAL ENDOCRINOLOGY, 2016, 32 : 152 - 152
  • [29] ENDOMETRIAL CAVITY LENGTH, NOT JUST ENDOMETRIAL CAVITY THICKNESS, AS A PREDICTOR FOR LIVE BIRTH RATE IN PATIENTS USING DONOR OOCYTES.
    Lewis, C. B.
    Jungheim, E.
    Arbelaez, A.
    Williams, M.
    Cooper, A. R.
    FERTILITY AND STERILITY, 2017, 108 (03) : E358 - E359
  • [30] Primary retroperitoneal endometrial cystadenocarcinoma presenting as pelvic abscess on ultrasound
    Youssef, C.
    Mathelin, C.
    Guerin, C.
    Roy, C.
    Walter, P.
    Rodriguez, B.
    Brettes, J. P.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (06) : 714 - 715