3D ultrasound assessment of endometrial junctional zone anatomy as a predictor of the outcome of ICSI cycles

被引:9
|
作者
Maged, Ahmed M. [1 ]
Ramzy, Abdel-Maguid [1 ]
Ghar, Mona Aboul [1 ]
El Shenoufy, Hossam [1 ]
Allah, Sherine H. Gad [1 ]
Wahba, Amr H. [1 ]
ElKateb, AbdAllah Y. [1 ]
Hwedi, Noha [1 ]
机构
[1] Cairo Univ, Kasr AlAiny Hosp, Obstet & Gynecol Dept, Giza, Giza Governorat, Egypt
关键词
Junctional zone; Uterus; ICSI; 3D ultrasound; UTERUS; ADENOMYOSIS; MYOMETRIAL;
D O I
10.1016/j.ejogrb.2017.03.035
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To study the relation between junctional zone thickness (JZ) and success of implantation in IVF/ICSI cycles. Study design: A prospective study included 100 infertility patients undergoing ICSI. The long protocol was used in all patients. JZ was measured using 3D ultrasound, in the coronal section, at three places, on two occasions. First measurement was done before HMG was started (i.e. when down regulation was achieved). Second measurement was done on the day of ovum pick up (OPU). Follow up after treatment was done to determine the rate of implantation. Results: There was a highly significant difference between pregnant and non pregnant treated women regarding the measurement of JZ at the day of OPU at all sites named fundal (0.27 +/- 0.1 vs. 0.38 +/- 0.14), anterior (0.28 +/- 0.07 vs. 0.36 +/- 0.09), posterior (0.32 +/- 0.1 vs. 0.37 +/- 0.09) and average (0.29 +/- 0.08 vs. 0.37 +/- 0.09) respectively. The cut off value, sensitivity and specificity of measurement of JZ at fundus were (<= 0.31,90% and 66.7%), at anterior wall were (<= 0.35,90% and 60%), at posterior wall (<= 0.25, 50% and 93.3%) and average were (<= 0.32,70% and 70%) respectively. Conclusion: The thinner the junctional zone at day of OPU, the higher the implantation rate and the difference between JZ measured at the day of down regulation and the day of OPU is a predictor of the outcome of ICSI cycles. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 50 条
  • [1] 3D Ultrasound assessment of endometrial receptivity during ivf/icsi cycles
    Ziogas, A.
    Gkoulovagka, D.
    Grapsidi, V.
    Xydias, E.
    Papageorgouli, D.
    Kalantzi, S.
    Daponte, A.
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2022, 270 : E92 - E93
  • [2] Role of 3D Ultrasound and Power Doppler in the prediction of IVF/ICSI outcome
    Rao, A.
    Giridharan, P.
    Rao, D.
    Rao, S.
    HUMAN REPRODUCTION, 2015, 30 : 266 - 266
  • [3] Predictive value of 3D ultrasound assessment of endometrial receptivity for PGD/PGS for transfer pregnancy outcome
    Sun, Kaixuan
    Xiu, Yinling
    Wang, Yinghua
    Yu, Tingting
    Lu, Xiaoli
    Wang, Xiliang
    Yu, Yuexin
    BMC PREGNANCY AND CHILDBIRTH, 2023, 23 (01)
  • [4] Predictive value of 3D ultrasound assessment of endometrial receptivity for PGD/PGS for transfer pregnancy outcome
    Kaixuan Sun
    Yinling Xiu
    Yinghua Wang
    Tingting Yu
    Xiaoli Lu
    Xiliang Wang
    Yuexin Yu
    BMC Pregnancy and Childbirth, 23
  • [5] Deep Learning Based Junctional Zone Quantification using 3D Transvaginal Ultrasound in Assisted Reproduction
    Singhal, Nitin
    Kudavelly, Srinivas
    Ramaraju, G. A.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 2133 - 2136
  • [6] Using 2D/3D ultrasound observation of endometrial thickness, endometrial volume, and blood flow changes to predict the outcome of frozen embryo transfer cycles: a prospective study
    Liu, Yan
    Yue, Qingxiong
    Wang, Lei
    Wang, Meixian
    Huang, Ying
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (06) : 3915 - 3926
  • [7] INTEROBSERVER AND INTERDISCIPLINARY RELIABILITY OF 3D ENDOVAGINAL ULTRASOUND ASSESSMENT OF PELVIC FLOOR ANATOMY
    Santoro, G. A.
    Wieczorek, P.
    Shobeiri, S. A.
    Mueller, E.
    Pilat, J.
    Stankiewicz, A.
    Battistella, G.
    NEUROUROLOGY AND URODYNAMICS, 2010, 29 (06) : 864 - 866
  • [8] INTEROBSERVER AND INTERDISCIPLINARY RELIABILITY OF 3D ENDOVAGINAL ULTRASOUND ASSESSMENT OF PELVIC FLOOR ANATOMY
    Santoro, G. A.
    Wieczorek, P.
    Shobeiri, S. A.
    Mueller, E.
    Pilat, J.
    Stankiewicz, A.
    Battistella, G.
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2010, 21 : S60 - S62
  • [9] Interobserver and interdisciplinary reproducibility of 3D endovaginal ultrasound assessment of pelvic floor anatomy
    Santoro, Giulio Aniello
    Wieczorek, Andrzej Pawel
    Shobeiri, S. Abbas
    Mueller, Elizabeth R.
    Pilat, Jacek
    Stankiewicz, Aleksandra
    Battistella, Giuseppe
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2011, 22 (01) : 53 - 59
  • [10] Interobserver and interdisciplinary reproducibility of 3D endovaginal ultrasound assessment of pelvic floor anatomy
    Giulio Aniello Santoro
    Andrzej Paweł Wieczorek
    S. Abbas Shobeiri
    Elizabeth R. Mueller
    Jacek Pilat
    Aleksandra Stankiewicz
    Giuseppe Battistella
    International Urogynecology Journal, 2011, 22 : 53 - 59