Utility of Contrast-Enhanced Ultrasound in Optimizing Hepatic Abscess Treatment and Monitoring

被引:0
|
作者
Dobek, Adam [1 ]
Kobierecki, Mateusz [2 ]
Kosztowny, Konrad [3 ]
Grzasiak, Oliwia [3 ]
Fabisiak, Adam [4 ]
Falenta, Krzysztof [1 ]
Stefanczyk, Ludomir [1 ]
机构
[1] Med Univ Lodz, Norbert Barlicki Mem Teaching Hosp 1, Dept Radiol & Diag Imaging, PL-90153 Lodz, Poland
[2] Polish Mothers Mem Hosp Res Institite, Dept Diag Imaging, PL-90153 Lodz, Poland
[3] Med Univ Lodz, Norbert Barlicki Mem Teaching Hosp 1, Dept Gen Surg & Transplantol, PL-90153 Lodz, Poland
[4] Med Univ Lodz, Norbert Barlicki Mem Teaching Hosp 1, Dept Digest Tract Dis, PL-90153 Lodz, Poland
关键词
abscess; contrast-enhanced ultrasound; liver; percutaneous drainage; ultrasound; LIVER-ABSCESS; DRAINAGE; MANAGEMENT; CEUS;
D O I
10.3390/jcm13175046
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Untreated hepatic abscesses (HAs) have an 80% mortality rate and can be caused by bacteria and fungi. Previously managed with surgery, current treatments now utilize interventional radiology and antibiotics, reducing complications to 2.5%. This study evaluates contrast-enhanced ultrasound (CEUS) for better drainage placement and monitoring, overcoming conventional ultrasound's limitations in detecting the HA liquefied portion. Methods: We conducted a retrospective study of 50 patients with HAs confirmed via computed tomography (CT) scans. Inclusion criteria comprised specific clinical symptoms and laboratory parameters. Both B-mode and CEUS were utilized for initial and follow-up imaging. Results: In the CEUS studies, the mean size of HAs was 6.26 cm, with pus displaying significantly lower echogenicity compared to the HA pouch and liver parenchyma in all phases. Classification by size (>6 cm, <6 cm) and volume (>113 mL, <113 mL) revealed differences in the assessment of fluid volume between CEUS and B-mode. Conclusions: CEUS is valuable for diagnosing, performing therapeutic procedures, and monitoring HA. It provides precise real-time assessment of HA morphology, including dimensions and volume. If the liquefied volume of an HA exceeds 113 mL, it may qualify for drainage placement. CEUS can replace CT as an effective, less harmful, and cheaper method, eliminating the need for multiple radiological departments. While CEUS is a safer, cost-effective alternative to CT for HA evaluation and monitoring, comprehensive clinical evaluation remains essential. Therefore, CEUS should be part of a broader diagnostic and monitoring strategy, not a stand-alone solution.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Baseline and contrast-enhanced ultrasound features of hepatic epithelioid angiomyolipoma
    Fan, Pei-Li
    Ji, Zheng-Biao
    Cao, Jia-Ying
    Xu, Chen
    Dong, Yi
    Wang, Wen-Ping
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2022, 80 (04) : 447 - 461
  • [32] Contrast-enhanced ultrasound of histologically proven hepatic epithelioid hemangioendothelioma
    Dong, Yi
    Wang, Wen-Ping
    Cantisani, Vito
    D'Onofrio, Mirko
    Ignee, Andre
    Mulazzani, Lorenzo
    Saftoiu, Adrian
    Sparchez, Zeno
    Sporea, Ioan
    Dietrich, Christoph F.
    WORLD JOURNAL OF GASTROENTEROLOGY, 2016, 22 (19) : 4741 - 4749
  • [33] The role of contrast-enhanced ultrasound in the diagnosis of hepatic alveolar echinococcosis
    Cai, Diming
    Li, Yongzhong
    Jiang, Yong
    Wang, Huiyao
    Wang, Xiaoling
    Song, Bin
    MEDICINE, 2019, 98 (05)
  • [34] Contrast-enhanced ultrasound in diagnosis and characterization of focal hepatic lesions
    Gomez Molins, Ines
    Fernandez Font, Juan Manuel
    Carrero Alvaro, Juan
    Lledo Navarro, Jose Luis
    Fernandez Gil, Marta
    Fernandez Rodriguez, Conrado M.
    WORLD JOURNAL OF RADIOLOGY, 2010, 2 (12): : 455 - 462
  • [35] Contrast-enhanced ultrasound of histologically proven hepatic epithelioid hemangioendothelioma
    Yi Dong
    Wen-Ping Wang
    Vito Cantisani
    Mirko D'Onofrio
    Andre Ignee
    Lorenzo Mulazzani
    Adrian Saftoiu
    Zeno Sparchez
    Ioan Sporea
    Christoph F Dietrich
    World Journal of Gastroenterology, 2016, 22 (19) : 4741 - 4749
  • [36] Antiangiogenic Tumor Treatment Noninvasive Monitoring with Contrast Pulse Sequence Imaging for Contrast-Enhanced Grayscale Ultrasound
    Zhou, Jianhua
    Zheng, Wei
    Cao, Longhui
    Liu, Min
    Han, Feng
    Li, Anhua
    ACADEMIC RADIOLOGY, 2010, 17 (05) : 646 - 651
  • [37] Microbubbles in the belly: optimizing the protocol for contrast-enhanced ultrasound of the pediatric abdomen
    Lauramay Davis
    Susan J. Back
    Pediatric Radiology, 2023, 53 : 1224 - 1236
  • [38] Microbubbles in the belly: optimizing the protocol for contrast-enhanced ultrasound of the pediatric abdomen
    Davis, Lauramay
    Back, Susan J.
    PEDIATRIC RADIOLOGY, 2023, 53 (07) : 1224 - 1236
  • [39] Diagnostic utility of contrast-enhanced ultrasound endoscopy in a case of hemosuccus pancreaticus
    Tanabe, Kiyokuni
    Kanno, Atsushi
    Ikeda, Eriko
    Ando, Kozue
    Yokoyama, Kensuke
    Yamamoto, Hironori
    ENDOSCOPY, 2024, 56 : E382 - E383
  • [40] Utility Of Contrast-Enhanced Ultrasound With Sonovue In Biopsy Of Small Subpleural Nodules
    Wang, J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191