Utility of Contrast-Enhanced Ultrasound in Optimizing Hepatic Abscess Treatment and Monitoring

被引:0
|
作者
Dobek, Adam [1 ]
Kobierecki, Mateusz [2 ]
Kosztowny, Konrad [3 ]
Grzasiak, Oliwia [3 ]
Fabisiak, Adam [4 ]
Falenta, Krzysztof [1 ]
Stefanczyk, Ludomir [1 ]
机构
[1] Med Univ Lodz, Norbert Barlicki Mem Teaching Hosp 1, Dept Radiol & Diag Imaging, PL-90153 Lodz, Poland
[2] Polish Mothers Mem Hosp Res Institite, Dept Diag Imaging, PL-90153 Lodz, Poland
[3] Med Univ Lodz, Norbert Barlicki Mem Teaching Hosp 1, Dept Gen Surg & Transplantol, PL-90153 Lodz, Poland
[4] Med Univ Lodz, Norbert Barlicki Mem Teaching Hosp 1, Dept Digest Tract Dis, PL-90153 Lodz, Poland
关键词
abscess; contrast-enhanced ultrasound; liver; percutaneous drainage; ultrasound; LIVER-ABSCESS; DRAINAGE; MANAGEMENT; CEUS;
D O I
10.3390/jcm13175046
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Untreated hepatic abscesses (HAs) have an 80% mortality rate and can be caused by bacteria and fungi. Previously managed with surgery, current treatments now utilize interventional radiology and antibiotics, reducing complications to 2.5%. This study evaluates contrast-enhanced ultrasound (CEUS) for better drainage placement and monitoring, overcoming conventional ultrasound's limitations in detecting the HA liquefied portion. Methods: We conducted a retrospective study of 50 patients with HAs confirmed via computed tomography (CT) scans. Inclusion criteria comprised specific clinical symptoms and laboratory parameters. Both B-mode and CEUS were utilized for initial and follow-up imaging. Results: In the CEUS studies, the mean size of HAs was 6.26 cm, with pus displaying significantly lower echogenicity compared to the HA pouch and liver parenchyma in all phases. Classification by size (>6 cm, <6 cm) and volume (>113 mL, <113 mL) revealed differences in the assessment of fluid volume between CEUS and B-mode. Conclusions: CEUS is valuable for diagnosing, performing therapeutic procedures, and monitoring HA. It provides precise real-time assessment of HA morphology, including dimensions and volume. If the liquefied volume of an HA exceeds 113 mL, it may qualify for drainage placement. CEUS can replace CT as an effective, less harmful, and cheaper method, eliminating the need for multiple radiological departments. While CEUS is a safer, cost-effective alternative to CT for HA evaluation and monitoring, comprehensive clinical evaluation remains essential. Therefore, CEUS should be part of a broader diagnostic and monitoring strategy, not a stand-alone solution.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Giant Right Atrial Diverticulum: Utility of Contrast-enhanced Ultrasound
    Sanchez-Brotons, Juan A.
    Lopez-Pardo, Francisco J.
    Lopez-Haldon, Jose E.
    Rodriguez-Puras, Maria J.
    REVISTA ESPANOLA DE CARDIOLOGIA, 2013, 66 (03): : 222 - 223
  • [22] Contrast-Enhanced Ultrasound
    Hunt, David
    Romero, Javier
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2017, 25 (04) : 725 - +
  • [23] Contrast-Enhanced Ultrasound
    Xu, Hui-Xiong
    Weskott, Hans Peter
    Liu, Ji-Bin
    Zheng, Rong-Qin
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [24] Contrast-enhanced ultrasound
    Jaspers, N.
    Pfister, R.
    Kinkel, H.
    Michels, G.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2012, 137 (45) : 2336 - 2339
  • [25] Klebsiella Pneumoniae Liver Abscess Syndrome - A Challenge for Contrast-Enhanced Ultrasound
    Bielow, Tobias
    Blank, Valentin
    Opitz, Sabine
    Gossmann, Holger
    Hecker, Martin
    Seehofer, Daniel
    Lubbert, Christoph
    Karlas, Thomas
    ULTRASOUND INTERNATIONAL OPEN, 2021, 07 (01) : E2 - E5
  • [26] Intracavitary contrast-enhanced ultrasound in abscess drainage - feasibility and clinical value
    Ignee, Andre
    Jenssen, Christian
    Cui, Xin-Wu
    Schuessler, Gudrun
    Dietrich, Christoph Frank
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2016, 51 (01) : 41 - 47
  • [27] Comparative efficacy of contrast-enhanced ultrasound versus B-mode ultrasound in the diagnosis and monitoring of hepatic abscesses
    Dobek, Adam
    Kobierecki, Mateusz
    Ciesielski, Wojciech
    Grzasiak, Oliwia
    Kosztowny, Konrad
    Fabisiak, Adam
    Bialek, Piotr
    Stefanczyk, Ludomir
    POLISH JOURNAL OF RADIOLOGY, 2024, 89 : e470 - e479
  • [28] Percutaneous treatment of blunt hepatic and splenic trauma under contrast-enhanced ultrasound guidance
    Lv, Faqin
    Tang, Jie
    Luo, Yukun
    Nie, Yongkang
    Jiao, Ziyu
    Li, Tanshi
    Zhou, Xuan
    CLINICAL IMAGING, 2012, 36 (03) : 191 - 198
  • [29] Clinical utility of microbubble contrast-enhanced ultrasound in the diagnosis of hepatic artery occlusion after liver transplantation
    Berstad, Audun Elnaes
    Brabrand, Knut
    Foss, Aksel
    TRANSPLANT INTERNATIONAL, 2009, 22 (10) : 954 - 960
  • [30] Contrast-enhanced ultrasound for blunt hepatic trauma: an animal experiment
    Li Yekuo
    Wang Shasha
    Zhu Xiansheng
    Chen Qi
    Luo Guoxin
    Huo Feng
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2010, 28 (07): : 828 - 833